Pressure Relief Procedure

4. Verify the trigger lock is engaged.

To relieve fluid and air pressures:

1. Push down Yellow slide valve, P/N 21402-00 to bleed off air to system.

2.Open P/N 21228-00 on catalyst pump to recirculation position.

3. Open P/N 21192-00 on bottom of material pump.

Daily Maintenance

It is recommended that the following service be per- formed on a daily basis.

1. Remove gear cover, p/n: 23789-00, and inspect valves to see if there is any leakage, on the top or bottom side of the valves. if there is leakage, with pressure relieved, tighten packing nut, p/n: 23764-00 1/8 to 1/4 turn until leak stops. Verify that there is no leakage.

4. Maintain a reasonable stock level of “wear” items such as Packings, Seals and O-Rings

5. If dispense gun is leak tested, be sure to dry gun thoroughly.

6. Never leave dispense gun immersed in any liquid.

12

GC-1393F

Image 12
Contents Formula-X Contents Fire and Explosion Hazard Skin Injection Hazard Methyl Ethyl Ketone Peroxide Mekp Polyester Resins and Gel-CoatsSpraying and Lamination Operations Grounding Set-Up Hose AttachmentParts Standard EquipmentPart Description Repair KitsAssembly Drawings Formula X Dispense Gun189018 Formula X Dispense Gun Part Description Qty Part Description QtyPressure Relief Procedure Daily MaintenanceMaintenance Parts Replacement Procedure Formula GunMaintenance Options Part Orifice NumberOptions Technical Data Category DataGraco Ohio Standard Warranty Graco Ohio Information