Maintenance

1. Ensure bores are clean before building material valves.

2. Insert bearing, p/n: 23768-01 into gun body.

3. Insert seal, p/n: 23763-00 into gun body. (Ensure holes in seal are aligned with holes in gun body.)

4. Place PTFE washers, p/n: 23721-04 on top and bottom of fluid valve, p/n: 23743-00.

5. Lubricate outside of fluid valve, p/n: 23743-00 with a generous amount of Aqua lube (21266-00) and insert into seal with holes aligned with holes in the gun body.

6. Insert bearing, p/n: 23768-01 into gun body.

7. a. Use 3/8 in. twelve point socket to first snug P/N 23764-00 to hand tight, continue ½ turn past snug. Torque reading 20 ft lbs / 88 Newton.

b. Loosen ¼ turn and return until snug, continue ¼ turn past snug. Torque reading 25 ft lbs / 110 Newton.

c. Loosen ¼ turn and return until snug, continues 1/8 turn past snug. Torque reading 30 ft lbs/ 133 Newton.

8. With piston, p/n: 23755-00 pushed back (in on posi tion), Place packing disks, p/n: 23721-04 followed by gears, p/n: 23775-01 and tighten set screw.

9. Activate air and retract gun trigger. Loosen P/N 23764-00 until valve rotate, alternate adjustment if both valves were adjusted.

14

GC-1393F

Image 14
Contents Formula-X Contents Fire and Explosion Hazard Skin Injection Hazard Spraying and Lamination Operations Methyl Ethyl Ketone Peroxide MekpPolyester Resins and Gel-Coats Grounding Set-Up Hose AttachmentPart Description PartsStandard Equipment Repair KitsAssembly Drawings Formula X Dispense Gun189018 Formula X Dispense Gun Part Description Qty Part Description QtyPressure Relief Procedure Daily MaintenanceMaintenance Parts Replacement Procedure Formula GunMaintenance Options Part Orifice NumberOptions Technical Data Category DataGraco Ohio Standard Warranty Graco Ohio Information