Spray Pattern Diagnosis

The Patterns below resemble symptoms of spray pattern problems. Please refer to the accompanying possible problems if you are experiencing similar difficulties. The solution to each problem follows the problem in parentheses.

Problem 1:

1.The Pattern Control Knob (13) or (12a) is partially closed. (Open Pattern Control Knob.)

2.The material is too thick. (Thin material according to the manufacturer’s instructions.)

3.The air pressure is too low. (Increase air pressure within the Maximum PSI (40).)

Problem 2:

1.High air pressure. (Reduce air pressure.)

2.Not enough fluid. (Increase fluid.)

3.Pattern Control Knob (13) or (12a) open too much. (Partially close Pattern Control Knob.)

Problem 3:

1.Air Cap plugged. (Clean the Air Cap.)

2.Air cap loose or dirty seat. (Clean and tighten.)

3.Dried material on fluid tip. (Use a non-metallic point to clean the Air Cap.)

Problem 4:

1.Dirt on one side of the fluid tip. (Clean the fluid tip.)

2.Holes on one side of the Air cap are plugged. (Clean the Air cap with a non-metallic point.)

SKU 93974

For technical questions, please call 1-800-444-3353

Page 18

Image 18
Contents For technical questions and replacement parts, please call Piece Spray GUN KITRead all instructions before using this tool SpecificationsSafety Warnings and Precautions Save This ManualSKU For technical questions, please call California Health & Safety Code § 25249.5, et seq Unpacking Air ConnectionSmall Spray Gun Preparation Fan Direction and Pattern Adjustment Pattern AdjustmentFan Direction Too Coarse Correct Too Fine Tighten Loosen Techniques Operation Maintenance After each useAccessories Parts List, Large Gun SKU For technical questions, please call Parts List, Small Gun DiagramLimited 1 Year Warranty Warranty CardTroubleshooting ProblemSpray Pattern Diagnosis Problem Cause Solution Sputtering Spray