Harbor Freight Tools 43760 operating instructions Fan Direction and Pattern Adjustment

Page 8

IMPORTANT: The Spray Gun must be cleaned immediately after use. Improper cleaning is a common reason for the Spray Gun not to work.

Fan Direction and Pattern Adjustment

Note: Always make sure the Vent (45) is clear and unclogged.

Fan Direction

To change the direction of the fan from horizontal to vertical, loosen the Lock Ring and turn the Air Cap (1) 90 degrees. After the adjustment, tighten the Lock Ring by hand. See FIGURE 3 below.

Lock Ring

Horizontal Fan

FIGURE 3

Air Cap

Vertical Fan

 

 

Pattern Adjustment

Warning!! Never exceed the Maximum Inlet PSI of 55 PSI.

1.If you need to reduce the air pressure for specific areas, adjust the air compressor.

2.To set the pattern size specific to the job, use the Pattern Control Knob (14) (see FIGURE 1 on page 6). By turning it counterclockwise (all the way open), the pattern will flatten. Turn the Pattern Control Knob (14) clockwise for a round pattern.

See FIGURE 4 below.

FIGURE 4

Flat/Open

Round/Closed

SKU 43760

For technical questions, please call 1-800-444-3353;

Page 8

Troubleshooting section at end of manual.

 

 

Image 8
Contents For technical questions and replacement parts, please call 43760Contents Save This Manual Safety Warnings and PrecautionsRead all instructions before using this tool SKU For technical questions, please call SKU For technical questions, please call Air Connection Do not use latex paints with this Spray Gun Comparison Conventional versus Hvlp Spray GunsGeneral tips for Preparation Fan Direction Fan Direction and Pattern AdjustmentPattern Adjustment Too Coarse Correct Too Fine Tighten Loosen Techniques Solvent Selection After each usePart Description 24 23 Problem Spray Pattern DiagnosisProblem Cause Solution Sputtering Spray