Carrier 50VL---A installation instructions AIR Conditioner with Puron R-410A Quick Reference Guide

Page 29

AIR CONDITIONER WITH PURON (R-410A) QUICK REFERENCE GUIDE

Puron refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with Puron. Puron refrigerant cylinders are rose colored.

SPuron refrigerant cylinders manufactured prior to March 1, 1999, have a dip tube that allows liquid to flow out of cylinder in upright position.

Cylinders manufactured March 1, 1999 and later DO NOT have a dip tube and MUST be positioned upside down to allow liquid to flow.

SRecovery cylinder service pressure rating must be 400 psig. DOT 4BA400 or DOT BW400.

SPuron systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose. S Manifold sets should be minimum 700 psig high-side and 180 psig low-side with 550 psig low-side retard.

S Use hoses with minimum 700 psig service pressure rating.

S Leak detectors should be designed to detect HFC refrigerant. S Puron, as with other HFCs, is only compatible with POE oils. S Vacuum pumps will not remove moisture from oil.

S Only use factory specified liquid-line filter driers with rated working pressures no less than 600 psig. S Do not install a suction-line filter drier in liquid line.

S POE oils absorb moisture rapidly. Do not expose oil to atmosphere. S POE oils may cause damage to certain plastics and roofing materials. S Wrap all filter driers and service valves with wet cloth when brazing. S A Puron liquid-line filter drier is required on every unit.

S Do not use an R-22 TXV.

S Never open system to atmosphere while it is under a vacuum.

S When system must be opened for service, break vacuum with dry nitrogen and replace filter driers. S Always replace filter drier after opening system for service.

S Do not vent Puron into the atmosphere.

S Observe all warnings, cautions, and bold text.

S Do not leave Puron suction line driers in place for more than 72 hrs.

50VL-- A

29

Image 29
Contents Safety Considerations Table of ContentsIntroduction Receiving and InstallationCheck Equipment Provide Unit Support50VL-A24-36 Unit Dimensions 50VL-A42-60 Unit Dimensions CPRFCURB010A00 SizeCPRFCURB011A00 CPRFCURB012A00Small Cabinet Large Cabinet 50VL-A Unit Suggested RiggingField-Fabricate Ductwork Provide ClearancesRig and Place Unit InspectionConnect Condensate Drain Install Duct ConnectionsConfiguring Units for Downflow Vertical Discharge Unit Component Damage Hazard Install Electrical ConnectionsHIGH-VOLTAGE Connections Control Voltage Connections Special Procedures for 208-V OperationStandard Connection Transformer ProtectionMinimum Airflow for Safe Electric Heater Operation CFM Physical Data-Unit 50VL-APRE-START-UP Start-Up Cooling Section And Make AdjustmentsSTART-UP Check for Refrigerant LeaksUnit Operation Hazard Indoor Airflow and Airflow ADJUST- MentsContinuous FAN Operation Single Speed Cooling with Higher Electric Heat SpeedCooling Sequence of Operation Color Coding for Indoor Fan Motor LeadsDry Coil Air Delivery Downflow Discharge Unit Motor Speed Wire ColorElectric Heat Pressure Drop Tables IN. W.C Small Cabinet Horizontal and Downflow Filter Pressure Drop Table IN. W.CLarge Cabinet Unit Standard CFM Scfm Size50VL a Cont. Ladder Wiring Diagram 208/230-1-60 Connection Wiring Diagram 208/230-3-60 Cont. Ladder Wiring Diagram 208/230-3-60 Connection Wiring Diagram 50VL500271 Cooling Charging Chart Air Filter MaintenanceIndoor Blower and Motor Personal Injury and Unit Damage HazardOutdoor FAN Electrical Controls and WiringOutdoor Coil, Indoor Coil, and Condensate Drain Pan Loss of Charge/Low-Pressure Switch Air Conditioner Only Pressure SwitchesHigh-Pressure Switch Refrigerant CircuitSTART-UP Checklist TroubleshootingSymptom Cause Remedy Troubleshooting ChartAIR Conditioner with Puron R-410A Quick Reference Guide Remove and Store in Job Files TemperaturesPreliminary Information Model no III. START-UP Electrical Supply Voltage Compressor Amps

50VL---A specifications

The Carrier 50VL---A is a powerhouse in the field of air conditioning and heating solutions, designed for residential and commercial applications. This unit exemplifies Carrier’s commitment to efficiency, reliability, and advanced technology. One of the standout features of the 50VL---A is its superior energy efficiency, which is reflected in its high Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF) ratings. These ratings ensure reduced energy consumption and lower utility bills, making it an environmentally friendly choice.

The 50VL---A is designed with a robust scroll compressor that not only enhances performance but also minimizes noise levels during operation. This compressor is integral to the system’s ability to maintain a consistent temperature and humidity level within the space. The unit’s sound-dampening features contribute to a quieter environment, which is particularly important in residential settings.

One of the key technologies integrated into the Carrier 50VL---A is the advanced microprocessor control system. This technology allows for precise temperature adjustments and operational diagnostics, making maintenance easier and more efficient. This system ensures that the unit operates at optimal performance, adapting to changing environmental conditions with ease.

Moreover, the 50VL---A is equipped with a multi-speed blower motor that provides enhanced airflow and comfort. This feature allows users to select different cooling or heating levels according to their specific requirements, promoting customized comfort throughout the home or office.

In addition to its performance capabilities, the Carrier 50VL---A is also built with longevity and durability in mind. The cabinet is constructed from high-quality materials that offer resistance to corrosion and wear, ensuring the unit can withstand various weather conditions over time. Furthermore, the unit’s maintenance-friendly design allows for easy access to key components, simplifying servicing and prolonging the life of the system.

Overall, the Carrier 50VL---A stands out as a reliable and advanced solution for climate control. With its energy-efficient operation, quiet performance, and user-friendly features, it represents a significant investment in home comfort and efficiency. Whether for heating during the colder months or cooling in the summer, the 50VL---A delivers exceptional performance, making it a popular choice among users seeking quality HVAC solutions.