Carrier 50VL---A Size, CPRFCURB010A00, CPRFCURB011A00, CPRFCURB012A00, CPRFCURB013A00

Page 5

HVAC unit

HVAC unit

base rails

basepan

 

Sealing

 

Gasket

 

Roofcurb

Anchor screw

Wood nailer*

Flashing field

 

supplied

Roofcurb*

 

Insulation

Roofing material

(field supplied)

 

field supplied

 

Cant strip

 

field supplied

 

*Provided with roofcurb

A09090

B

G C

F

H

A

D

SMALL/COMMON CURB

Dashed lines show cross support location for large basepan units.

E

A09413

50VL-- A

ROOF CURB DETAIL

B

C

G

H F A

D

LARGE CURB

E

A09415

 

 

 

SMALL

 

SUPPLY

 

 

 

BASE

 

AIR

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LARGE

RETURN

BASE

AIR

UNIT

 

 

 

 

UNIT PLACEMENT ON

COMMON CURB

A09094

SMALL OR LARGE BASE UNIT

A09414

UNIT

CATALOG

A

B

B

C

D

E

F

G

H

(small/common

IN.

(large base)

IN.

IN.

IN.

IN.

SIZE

NUMBER

base)

IN. (mm)

IN. (mm)

(mm)

IN. (mm)*

(mm)

(mm)

(mm)

(mm)

 

 

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small

CPRFCURB010A00

11

 

 

 

 

 

 

 

 

(279)

 

 

 

 

32.4

 

 

 

 

 

 

 

 

 

 

 

or

 

 

10 (254)

 

 

 

(822)

 

30.6 (778)

 

Large

CPRFCURB011A00

14

 

 

 

 

 

 

 

(356)

 

14 (356)

16

47.8

 

2.7

 

46.1 (1170)

 

 

 

 

 

 

 

 

 

(406)

(1214)

 

(69)

 

 

CPRFCURB012A00

11

 

 

 

 

 

 

 

 

 

Large

(279)

14 (356)

 

 

 

43.9

 

42.2 (1072)

 

 

 

 

 

 

 

 

 

 

 

 

(1116)

 

 

CPRFCURB013A00

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(356)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan.

NOTES:

1.Roof curb must be set up for unit being installed.

2.Seal strip must be applied, as required, to unit being installed.

3.Roof curb is made of 16-gauge steel.

4.Attach ductwork to curb (flanges of duct rest on curb).

5.Insulated panels: 1-in. (25.4 mm) thick fiberglass 1 lb. density.

Fig. 4 - Roof Curb Dimensions

5

Image 5
Contents Safety Considerations Table of ContentsIntroduction Receiving and InstallationCheck Equipment Provide Unit Support50VL-A24-36 Unit Dimensions 50VL-A42-60 Unit Dimensions CPRFCURB010A00 SizeCPRFCURB011A00 CPRFCURB012A00Small Cabinet Large Cabinet 50VL-A Unit Suggested RiggingField-Fabricate Ductwork Provide ClearancesRig and Place Unit InspectionConnect Condensate Drain Install Duct ConnectionsConfiguring Units for Downflow Vertical Discharge Unit Component Damage Hazard Install Electrical ConnectionsHIGH-VOLTAGE Connections Control Voltage Connections Special Procedures for 208-V OperationStandard Connection Transformer ProtectionMinimum Airflow for Safe Electric Heater Operation CFM Physical Data-Unit 50VL-APRE-START-UP Start-Up Cooling Section And Make AdjustmentsSTART-UP Check for Refrigerant LeaksUnit Operation Hazard Indoor Airflow and Airflow ADJUST- MentsContinuous FAN Operation Single Speed Cooling with Higher Electric Heat SpeedCooling Sequence of Operation Color Coding for Indoor Fan Motor LeadsDry Coil Air Delivery Downflow Discharge Unit Motor Speed Wire ColorElectric Heat Pressure Drop Tables IN. W.C Small Cabinet Horizontal and Downflow Filter Pressure Drop Table IN. W.CLarge Cabinet Unit Standard CFM Scfm Size50VL a Cont. Ladder Wiring Diagram 208/230-1-60 Connection Wiring Diagram 208/230-3-60 Cont. Ladder Wiring Diagram 208/230-3-60 Connection Wiring Diagram 50VL500271 Cooling Charging Chart Air Filter MaintenanceIndoor Blower and Motor Personal Injury and Unit Damage HazardOutdoor FAN Electrical Controls and WiringOutdoor Coil, Indoor Coil, and Condensate Drain Pan Loss of Charge/Low-Pressure Switch Air Conditioner Only Pressure SwitchesHigh-Pressure Switch Refrigerant CircuitSTART-UP Checklist TroubleshootingSymptom Cause Remedy Troubleshooting ChartAIR Conditioner with Puron R-410A Quick Reference Guide Remove and Store in Job Files TemperaturesPreliminary Information Model no III. START-UP Electrical Supply Voltage Compressor Amps

50VL---A specifications

The Carrier 50VL---A is a powerhouse in the field of air conditioning and heating solutions, designed for residential and commercial applications. This unit exemplifies Carrier’s commitment to efficiency, reliability, and advanced technology. One of the standout features of the 50VL---A is its superior energy efficiency, which is reflected in its high Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF) ratings. These ratings ensure reduced energy consumption and lower utility bills, making it an environmentally friendly choice.

The 50VL---A is designed with a robust scroll compressor that not only enhances performance but also minimizes noise levels during operation. This compressor is integral to the system’s ability to maintain a consistent temperature and humidity level within the space. The unit’s sound-dampening features contribute to a quieter environment, which is particularly important in residential settings.

One of the key technologies integrated into the Carrier 50VL---A is the advanced microprocessor control system. This technology allows for precise temperature adjustments and operational diagnostics, making maintenance easier and more efficient. This system ensures that the unit operates at optimal performance, adapting to changing environmental conditions with ease.

Moreover, the 50VL---A is equipped with a multi-speed blower motor that provides enhanced airflow and comfort. This feature allows users to select different cooling or heating levels according to their specific requirements, promoting customized comfort throughout the home or office.

In addition to its performance capabilities, the Carrier 50VL---A is also built with longevity and durability in mind. The cabinet is constructed from high-quality materials that offer resistance to corrosion and wear, ensuring the unit can withstand various weather conditions over time. Furthermore, the unit’s maintenance-friendly design allows for easy access to key components, simplifying servicing and prolonging the life of the system.

Overall, the Carrier 50VL---A stands out as a reliable and advanced solution for climate control. With its energy-efficient operation, quiet performance, and user-friendly features, it represents a significant investment in home comfort and efficiency. Whether for heating during the colder months or cooling in the summer, the 50VL---A delivers exceptional performance, making it a popular choice among users seeking quality HVAC solutions.