Date: | Supersedes: | COMBINATION HEATING/COOLING | 48T | Rev.: |
|
| UNITS |
| |
|
|
|
|
|
JOB NAME: | LOCATION: |
|
| |
|
|
|
|
|
BUYER: |
| BUYER P.O. # | CARRIER # |
|
|
|
|
| |
UNIT NUMBER: | MODEL NUMBER: |
|
| |
|
|
|
| |
UNIT DESIGNATION: |
|
|
| |
|
|
|
| |
PERFORMANCE DATA CERTIFIED BY: |
| DATE: |
| |
|
|
|
|
|
|
| DESCRIPTION |
|
|
Units are a single piece, gas heating/electric cooling unit, with a low profile,
FEATURES
•Standard
•
•
•Outdoor ambient cooling operation from 25 F
•Units are tested and certified by ARI and certified by UL and CSA.
•
•
•Hermetic compressor on independent circuit with internal line break and overload protection,
•Scroll compressor with internal overload protection (TF/TM007, TM012, TF014).
•Refrigerant circuit contains a filter drier to trap dirt and particles.
•Single compressor on 3 to 6 ton units.
•Dual compressors on 71/2 to 121/2 ton units.
•
•
•
•Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes.
•Single point electrical and gas connections.
•Direct drive propeller condenser fan totally enclosed with permanently lubricated bearings.
•
•Dedicated L,M,N 3 to 5 ton “Low NOx” units that meet California air quality refrigerant of 40 nanograms/joule or less.
•Large, easily removable panels provide ready access to unit components for rapid removal or maintenance.
•Filter access door for filter access and maintenance that requires no tools.
•Induced draft (negative pressure) combustion system with Hall effect sensor to detect proper operation of induced draft motor.
•All units have single stage cooling and single stage heating capability. High heat models have
•Heavy Alumagard™ coated heat exchangers, with aluminized steel burners.
•Heating controls with direct spark ignition and redundant gas valve. Fan switch, high temperature limit switch and flame rollout switch standard.
•Fixed orifice metering device precisely controls refrigerant flow to each circuit individually.
•Reliable accurate control circuit with color coded wires and easy acces- sible terminal board.
•Integrated gas control board with
•Integrated gas control board provides
•Loss of charge (low pressure), freeze protection, and high pressure switches standard.
•Refrigerant filter drier/circuit.
PERFORMANCE DATA
COOLING
Net Total Cap.___________________________________________ Btuh
Net Sensible Cap. ________________________________________ Btuh
Compressor Power Input ___________________________________ kW
_________________________________________ F Outdoor Air Temp.
Indoor Entering Air | db _____________ F | wb _______________ F |
CFM __________ | Ext. Static Pressure___________________ in. wg |
Fan RPM _______________________________________________ Bhp
SEER/EER _________________________________________________
HEATING
Input: | Stage 1 ___________________ Total______________ | Btuh |
Output: | Stage 1 ____________________ Total______________ | Btuh |
AFUE _______________________________ kW_________________%
Steady State _______________________________________________%
Operating Weight _______________ lbs. (unit)_____________ lbs. (curb)
ELECTRICAL DATA
Power Supply to Unit ________________ Volts ________________ Phase _________________________ Hz
Minimum Circuit Amps ______________ Maximum Overcurrent Protection (Fuse Only) _______________
FACTORY-INSTALLED
FIELD-INSTALLED ACCESSORIES
OPTIONS
Durablade Economizer — Fully Modulating EconoMi$er with Controller Copper/Copper Coils — Evaporator, Condenser, Both
25% Manual Air Damper
Alternate Motor and Drive (except 007 and 009 size)
EconoMi$er with
Durablade Economizer — Fully Modulating EconoMi$er
25% Open
25% Open Manual Air Damper
100% Open
Time Guard® II Compressor
Condenser Coil Hail Guard
Room Temperature Sensor PremierLink™ Control
Condenser Coil Protector
EconoMi$er/Power Exhaust
Kit
Programmable
Electrical Mechanical Thermostat & Subbase
Liquid Propane (LP) Gas Kit
Flue Hood Protector Kit
Flue Discharge Deflector
Indoor Fan/filter Status Indicator
62AQ Energy$Recycler
Other ____________________