Control Blocks and Interfaces
Control Blocks
A1 | Full Feature Control Block | A6 | Simple Control Block | |
| Part No. 436313 |
| Part No. 103862 | |
|
|
|
|
|
|
|
|
|
|
Air Connections
RAir Return Port – Connects to breather port in nose of tool to provide extra retract capability with heavy front end attachments (1/8” BSP)
ST | Start Button – For manual operation and |
1Remote Start Signal Port Pulse (M5)
SP | Manual Stop Button – Interrupts cycle and returns AFD to datum |
PRemote Stop Signal Port – Requires external signal pulse for returning the unit to datum rest position (M5)
OAir inlet (1/4” BSP or 1/4” NPT)
MWork Cycle Complete Port – Used for sequence control with other AFD’s clamps, index tables, etc (positive at datum position) (M5)
ODepth Stop Signal Port – Used with external circuits such as dwell or pecking (1/8” BSP)
Retract rate adjustment control
Advance rate adjustment control
Feed rate adjustment control
FFeed port (1/8” BSP)
RN | Return port (1/8” BSP) |
Electrical Connections | |
S1 | Start solenoid |
S2 | Stop solenoid |
SW1 | Datum return (M8 x 1.00) |
SW2 | Depth position (M8 x 1.00) |
Electrical Interfaces (not included with control blocks) |
| ||||
C10 | Part No. 438223 | C3 | Part No. 104002 | Solenoid Valves | |
| Comprises : |
| Comprises : | ALL 24V DC | |
| 2 x M8 Proximity Switches PNP (NO) |
| 2 x M8 Proximity Switches PNP (NO) | NC – Valve normally closed | |
| 2 x |
| 2 x | NO – Valve normally open | |
| 2 x Solenoid Valves (NC) | C5 | Part No. 104842 | Proximity Switches | |
C11 | Part No. 438233 | ||||
| Comprises : | All | |||
| Comprises : |
| 2 x M8 Proximity Switches NPN (NO) | NC – Normally closed | |
|
| NO – Normally open | |||
| 2 x M8 Proximity Switches PNP (NO) |
| 2 x | ||
| 2 x |
|
|
| |
| 1 x Solenoid Valve (NC) |
|
|
| |
| 1 x Solenoid Valve (NO) |
|
|
| |
C12 | Part No. 438243 |
|
|
| |
| Comprises : |
|
|
| |
| 2 x M8 Proximity Switches NPN (NO) |
|
|
| |
| 2 x |
|
|
| |
| 2 x Solenoid Valve (NC) |
|
|
|
AFD60 / AFT60 Control Block (Supplied fitted)
Air connection as above except M port which is negative at datum.
To invert signal use kit
Electrical Inputs and Outputs
24VD.C. Switched Red OV. Common Black 24VD.C. Switched Green Switch Yellow
Switch Common White Switch Blue
Part No. 104822
Electrical Interface
Part No. 79532
24V DC Comprises:
2 metre cable Adaptor and O ring Interface block