Environmental

Operating

5° to 40°C (41° to 104°F) with a maximum temperature gradation of 10°C per

 

hour

 

NOTE: For altitudes above 2950 feet, the maximum operating

 

temperature is derated 1°F per 550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum temperature gradation of

 

20°C per hour

Relative humidity

 

Operating

20% to 80% (noncondensing) with a maximum humidity gradation of 10% per

 

hour

Storage

5% to 95% (noncondensing)

Maximum vibration

 

Operating

0.26 G at 5–350 Hz for 15 min

Storage

1.88 G at 10–500 Hz for 15 min

Maximum shock

 

Operating

Half-sine shock 31 G +/- 5% with a pulse duration of 2.6 ms +/- 10% (in

 

operational orientations only)

Storage

Altitude

Half-sine shock 71 G +/- 5% with a pulse duration of 2 ms +/- 10% (all sides)

Square wave shock 27 G with a velocity change of 235 in. per sec (all sides)

Operating

–16 to 3048 m (–50 to 10,000 ft)

 

NOTE: For altitudes above 2950 feet, the maximum operating

 

temperature is derated 1°F per 550 ft.

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Airborne Contaminant Level

Class

G2 or lower as defined by ISA-S71.04- 1985

10

Image 10
Contents Dell Storage Center Page Before You Begin Unpacking Storage Center EquipmentInstalling the Expansion Enclosure in a Rack SC100/SC120 Expansion Enclosure ComponentsInstalling the Front Bezel Cabling the Expansion Enclosure to a Storage SystemConnecting the Power Cables Power CablesNOM Information Mexico Only Turning on the Expansion EnclosureEMM