Dell Md3860f manual Cabling The Storage Array, Switch Zoning Guidelines

Page 12

together, the switch allows the host server to see only devices included in that zone, decreasing the amount of time it would otherwise take for the host server to query attached, but out-of-zone, devices.

Switch Zoning Guidelines

The storage array imposes specific requirements that must be followed when setting up Fibre Channel switch zoning:

If a Fibre Channel switch is used to connect your host server and storage array, it must be zoned. Un- zoned or open switches cannot be used.

WWN port zoning is recommended. While hard zoning (zoning by device ID) is supported, LUN masking uses the WWN identifier. You can mix WWN and hard-zoned ports in the same zone.

Multi-port HBAs are supported. Each port in a multiple-port HBA represents one initiator. Each initiator must be connected to a single logical switch zone.

No more than four paths (port-to-port segments) can be established from a single, physical host server(s) to a single RAID controller.

A zone can contain multiple targets and span multiple storage arrays (single initiator can point to multiple targets).

NOTE: To simplify troubleshooting, you can assign a single initiator and single target to a zone.

If the Remote Replication premium feature is activated, a separate zone for each replication port is required. Only data traffic related to Remote Replication can move through that zone. For more details and requirements regarding Remote Replication, see the Dell PowerVault MD Series Storage Arrays Administrator's Guide at dell.com/powervaultmanuals.

Setting Up Zoning On The Fibre Channel Switch Hardware

Setting up zoning on Fibre Channel switches varies greatly between manufacturers. For detailed information on how to set up zoning on your switch, see the manufacturer’s product documentation or technical support website.

Cabling The Storage Array

Cabling the storage array depends on a number of factors such as:

Required level of redundancy or throughput

Number of host servers connected to the storage array

Type of HBAs (dual- or single-port) used in the host server(s)

Remote Replication premium feature (if applicable)

The cabling diagrams shown here do not represent every supported cabling scenario but the concepts of redundancy and switch logic can be used to build your own configuration.

Redundant And Non-Redundant Cabling

Non-redundant cabling configurations provide a single data path from host server(s) to the storage array. This type of configuration is only recommended for non-critical data storage. A path failure from a failed or removed cable, failed HBA, or failed or removed RAID controller module results in loss of host access to the storage array.

Redundant configurations establish separate data paths between the host server(s) and storage array. Each path is connected to separate RAID controller modules in the storage array. Redundancy protects

12

Image 12
Contents Page 、警示與警告 Contents Post Installation Tasks Uninstalling MD Storage ManagerLoad Balancing Appendix Working With SFP Modules And Fiber Optic CablesIntroduction System RequirementsIntroduction To Storage Arrays Management Station RequirementsRelated Documentation Contacting Dell Documentation feedbackHardware Installation Planning The Storage ConfigurationConnecting The Storage Array Configuring Fibre Channel Installing Supported Fibre Channel HBAs Using Fibre Channel Switch ZoningInstalling Fibre Channel HBA On Your Host Server Other Information You May NeedWorld Wide Name Zoning Switch Zoning Guidelines Setting Up Zoning On The Fibre Channel Switch HardwareCabling The Storage Array Redundant And Non-Redundant CablingSAN-Attached Cabling SAN-Attached Cabling ExampleServer1HBA0 Server1HBA1 Remote Replication Cabling Example Remote Replication Cabling Mixed Environment Cabling PowerVault MD3060e Expansion Enclosures Mixed EnvironmentMD3060e Expansion cabling diagrams Single expansion diagramExpanding With New PowerVault MD3060e Expansion Enclosures Dual expansion diagramPage Installing MD Storage Manager Installing Host Bus Adapters And Drivers Graphical Installation RecommendedConsole Installation Silent InstallationSilent Installation On Windows Silent Installation On LinuxEnabling Premium Features Optional Upgrading PowerVault MD Storage ManagerPost Installation Tasks Verifying Storage Array DiscoveryInitial Setup Tasks Uninstalling MD Storage Manager Uninstalling MD Storage Manager From WindowsUninstalling MD Storage Manager From Linux Least Path Weight Load BalancingLoad Balance Policy Round Robin With SubsetSetting Load Balance Policies in Linux Setting Load Balance Policies in VMwareGuidelines For Using SFP Modules Installing SFP ModulesAppendix Working With SFP Modules And Fiber Optic Cables Guidelines For Using Fibre Optic Cables Removing SFP ModulesInstalling Fibre Channel Cables Removing Fibre Channel CablesAppendix Hardware Cabling Best Practices Handling Static Sensitive ComponentsHost Cabling For Remote Replication Cabling For PerformanceLabeling Cables