Dell Md3860f manual Mixed Environment

Page 17

Switch Fabric A

Switch Fabric B

 

 

Array1_Ctrl-0-0

Array1_Ctrl-0-1

Array1_Ctrl-1-0

Array1_Ctrl-0-2

Array1_Ctrl-1-2

Array1_Ctrl-1-1

Zone4_Server3_HBA_0_1

Zone9_Server3_HBA_0_0

Server3_HBA_0_1

Server3_HBA_0_0

Array2_Ctrl-0-1

Array2_Ctrl-0-0

Array2_Ctrl-0-2

Array2_Ctrl-1-0

Array2_Ctrl-1-1

Array2_Ctrl-1-2

Zone5_Server3_HBA_1_1

Zone10_Server3_HBA_1_0

Server3_HBA_1_1

Server3_HBA_1_0

Array2_Ctrl-0-1

Array2_Ctrl-0-0

Array2_Ctrl-0-2

Array2_Ctrl-1-0

Array2_Ctrl-1-1

Array2_Ctrl-1-2

Replication_Zone_1

Replication_Zone_2

Array1_Ctrl-0-3

Array1_Ctrl-1-3

Array2_Ctrl-0-3

Array2_Ctrl-1-3

Mixed Environment

The following figure shows mixed configuration, that is SAS direct attached and host connectivity via the SAN (that is FC/Ethernet switch).

17

Image 17
Contents Page 、警示與警告 Contents Uninstalling MD Storage Manager Post Installation TasksLoad Balancing Appendix Working With SFP Modules And Fiber Optic CablesSystem Requirements IntroductionIntroduction To Storage Arrays Management Station RequirementsRelated Documentation Documentation feedback Contacting DellConnecting The Storage Array Hardware InstallationPlanning The Storage Configuration Configuring Fibre Channel Using Fibre Channel Switch Zoning Installing Supported Fibre Channel HBAsInstalling Fibre Channel HBA On Your Host Server Other Information You May NeedWorld Wide Name Zoning Setting Up Zoning On The Fibre Channel Switch Hardware Switch Zoning GuidelinesCabling The Storage Array Redundant And Non-Redundant CablingSAN-Attached Cabling Example SAN-Attached CablingServer1HBA0 Server1HBA1 Remote Replication Cabling Example Remote Replication Cabling Mixed Environment Mixed Environment Cabling PowerVault MD3060e Expansion EnclosuresSingle expansion diagram MD3060e Expansion cabling diagramsDual expansion diagram Expanding With New PowerVault MD3060e Expansion EnclosuresPage Installing MD Storage Manager Graphical Installation Recommended Installing Host Bus Adapters And DriversSilent Installation Console InstallationSilent Installation On Windows Silent Installation On LinuxUpgrading PowerVault MD Storage Manager Enabling Premium Features OptionalVerifying Storage Array Discovery Post Installation TasksInitial Setup Tasks Uninstalling MD Storage Manager From Windows Uninstalling MD Storage ManagerUninstalling MD Storage Manager From Linux Load Balancing Least Path WeightLoad Balance Policy Round Robin With SubsetSetting Load Balance Policies in VMware Setting Load Balance Policies in LinuxAppendix Working With SFP Modules And Fiber Optic Cables Guidelines For Using SFP ModulesInstalling SFP Modules Removing SFP Modules Guidelines For Using Fibre Optic CablesRemoving Fibre Channel Cables Installing Fibre Channel CablesHandling Static Sensitive Components Appendix Hardware Cabling Best PracticesHost Cabling For Remote Replication Cabling For PerformanceLabeling Cables