Carrier 38AKS013-024 specifications Nec, Ifc, LLSV2 Ð, Unit Compr, Icf, Rla Lra, Fla, Mca

Page 11

 

LEGEND

EQUIP GND Ð Equipment Ground

NEC

Ð National Electrical Code

Factory Wiring

Field Wiring

Fig. 7 Ð Main Power Supply Wiring

LEGEND

CÐ Compressor Contactor

HD

Ð Heating Device

IFC

Ð

Indoor-Fan Contactor

LLSV1 Ð Liquid Line Solenoid Valve 1 Ð Refrigerant Migration

LLSV2 Ð

Control

Liquid Line Solenoid Valve 2 Ð Capacity Control

RÐ Relay

Factory Wiring

Field Wiring

NOTES:

1.Combination LLSV plus IFC va should not exceed 30 va.

2.Do not exceed 5 va (24 vac) per coil.

3.If va values shown in Notes 1 and 2 must be exceeded, use accessory relay transformer package 38AE900001 (60 Hz) or 38AD900003 (50 Hz and 380-3-60).

Fig. 8 Ð Remote Thermostat Wiring

Table 6A Ð Electrical Data (3 Ph/60 Hz)

 

 

 

 

 

 

UNIT

 

 

 

 

 

COMPR

 

FAN MOTORS (Single Phase)

UNIT

 

 

 

Volts

 

 

 

 

 

MOCP

 

 

 

 

Total

FLA (ea)

 

38AKS

Model

 

 

Supplied*

MCA

 

ICF

(Fuse

 

RLA

 

LRA

Fan No.

kW

Nameplate

 

 

 

 

Fans

 

 

 

 

 

 

 

 

 

 

Only)

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

501

208-230

 

187

 

253

62.5

 

178

100

 

43.6

 

170

 

 

4.3

3.7

 

013

 

201

380

 

342

 

418

35.0

 

101

50

 

24.0

 

93

 

2

4.3

3.7

1.41

 

601

460

 

414

 

528

29.1

 

81

40

 

20.0

 

77

 

2.3

1.9

 

 

 

 

 

 

 

 

 

 

 

 

101

575

 

518

 

660

22.8

 

67

35

 

15.7

 

62

 

 

1.8

1.8

 

 

 

501

208-230

 

187

 

253

69.3

 

199

100

 

49.3

 

191

 

 

4.3

3.7

 

014

 

201

380

 

342

 

418

38.0

 

112

60

 

26.5

 

104

 

2

4.3

3.7

1.41

 

601

460

 

414

 

528

31.7

 

84

50

 

22.1

 

80

 

2.3

1.9

 

 

 

 

 

 

 

 

 

 

 

 

101

575

 

518

 

660

25.6

 

73

40

 

17.9

 

69

 

 

1.8

1.8

 

 

 

501

208-230

 

187

 

253

87.5

 

274

125

 

63.6

 

266

 

 

4.3

3.7

 

016

 

201

380

 

342

 

418

49.3

 

153

80

 

36.0

 

145

 

2

4.3

3.7

1.41

 

601

460

 

414

 

528

40.7

 

124

60

 

29.3

 

120

 

2.3

1.9

 

 

 

 

 

 

 

 

 

 

 

 

101

575

 

518

 

660

33.0

 

100

50

 

23.8

 

96

 

 

1.8

1.8

 

 

 

501

208-230

 

187

 

254

93.4

 

353

150

 

67.9

 

345

 

 

4.3

3.7

 

024

 

201

380

 

342

 

418

49.7

 

199

80

 

34.6

 

191

 

2

4.3

3.7

1.41

 

601

460

 

414

 

508

48.1

 

177

80

 

34.7

 

173

 

2.3

1.9

 

 

 

 

 

 

 

 

 

 

 

 

101

575

 

518

 

632

40.1

 

124

60

 

28.8

 

120

 

 

1.8

1.8

 

 

 

 

LEGEND

 

 

 

 

 

*Units are suitable for use on electrical systems where voltage sup-

FLA

Ð Full Load Amps (Fan Motors)

 

 

 

 

 

plied to the unit terminals is not below or above the listed limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICF

Ð Maximum Instantaneous Current Flow during start-up

 

NOTES:

 

 

 

 

 

 

 

 

(LRA of compressor plus total FLA of fan motors)

 

1. The MCA and MOCP

values are calculated in accordance

kW

Ð Total Fan Motor Input (kilowatts)

 

 

 

 

 

 

with the National Electrical Code (NEC) article 440 (U.S.A.

LRA

Ð Locked Rotor Amps

 

 

 

 

 

 

 

 

standard).

 

 

 

 

 

 

MCA

Ð Minimum Circuit Amps per NEC (U.S.A.),

 

 

 

2. Motor RLA

and LRA values are established in accordance

 

 

Section 430-24

 

 

 

 

 

 

 

 

with Underwriters' Laboratories (UL) Standard 1995 (U.S.A.

MOCP Ð Maximum Overcurrent Protection (amps)

 

 

 

 

standard).

 

 

 

 

 

 

RLA

Ð Rated Load Amps (Compressor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Image 11
Contents Installation ContentsSafety Considerations Dimensions Component Locations Typical Ð Physical Data English, 60 Hz OIL Charge L Condenser Fans Ð Physical Data SI, 60 HzÐ Physical Data English, 50 Hz Ð Physical Data SI, 50 Hz Liquid Line Data Weight DistributionRig and Mount the Unit Complete Refrigerant Piping ConnectionsÐ Refrigerant Piping Sizes Ð 60 Hz Units Length of Interconnecting PIPING, FT MLength of Interconnecting PIPING, FT M Cond Length of Interconnecting Piping FT MLocation of Sight Glasses Filter Driers Unit Compr NECIFC LLSV2 ÐMCA ICF PRE-START-UPSystem Check Ð Electrical Data 3 Ph/50 HzPreliminary Checks Adjust Refrigerant ChargeSTART-UP 38AKS013 and 38AKS024 Charging Chart 38AKS014 Charging Chart 38AKS016 Charging Chart Operating Sequence ServiceLubrication Compressor ProtectionOutdoor Fan Compressor Cycles on LOW-PRESSURE Switch TroubleshootingProblem Solution Compressor does not RUN Compressor Stops on HIGH-PRESSURE SwitchTroubleshooting Copyright 1998 Carrier Corporation Pre-Start-Up START-UP ChecklistPreliminary Information Start-Up

38AKS013-024 specifications

The Carrier 38AKS013-024 is a prominent series of packaged air conditioning units designed to achieve optimal performance across various applications. Engineered with advanced technologies, these units are ideal for both residential and light commercial spaces, offering reliable climate control in a compact design.

The main features of the Carrier 38AKS series include high-efficiency cooling and heating capabilities. With SEER ratings that meet or exceed industry standards, these units offer reduced energy consumption, making them an environmentally friendly choice. Furthermore, the Carrier 38AKS013-024 is equipped with a scroll compressor, which enhances reliability and reduces operating noise, creating a more comfortable indoor environment.

One of the standout technologies incorporated in the Carrier 38AKS series is its advanced microprocessor control system. This technology provides precise temperature control and allows for easy integration with smart home systems. Users can conveniently manage their indoor climate through remote access, ensuring comfort at all times.

Additionally, the 38AKS series boasts durable construction materials, ensuring longevity and sustained performance even in challenging environmental conditions. The units feature a galvanized steel cabinet with a rust-resistant finish, providing protection from the elements. This design also allows for easy access to internal components during maintenance, simplifying servicing.

In terms of characteristics, the Carrier 38AKS013-024 offers a range of cooling capacities, making it suitable for various space sizes and applications. The lightweight design facilitates easy installation, while the low noise levels ensure minimal disruption in residential settings. These units also come with environmentally friendly refrigerants, aligning with modern sustainability goals.

Carrier's commitment to quality and performance is evident in the 38AKS series. With their combination of innovative technology, energy efficiency, and robust construction, the Carrier 38AKS013-024 units represent an excellent choice for those seeking a reliable and efficient air conditioning solution. Whether for home or light commercial use, these units promise consistent comfort and satisfaction.