Ryobi TS1344L manual Double Insulation, Electrical Connection, Extension Cords, Cord Length

Page 7

ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power tools, which eliminates the need for the usual three- wire grounded power cord. All exposed metal parts are isolated from the internal metal motor components with protecting insulation. Double insulated tools do not need to be grounded.

WARNING:

The double insulated system is intended­ to protect the user from shock resulting from a break in the tool’s internal insulation. Observe all normal safety precautions to avoid electrical shock.

NOTE: Servicing of a tool with double insulation requires extreme care and knowledge of the system and should be performed only by a qualified service technician. For service, we suggest you return the tool to the nearest authorized service center for repair. Always use original factory replace- ment parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. It should be connected to a power supply that is 120 volts, 60 Hz, AC only (normal household current). Do not operate this tool on direct current (DC). A substantial voltage drop will cause a loss of power and the motor will overheat. If the tool does not operate when plugged into an outlet, double-check the power supply.

EXTENSION CORDS

When using a power tool at a considerable distance from a power source, be sure to use an extension cord that has the capacity to handle the current the tool will draw. An undersized cord will cause a drop in line voltage, resulting in overheating and loss of power. Use the chart to determine the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter’s Laboratories (UL) should be used.

When working outdoors with a tool, use an extension cord that is designed for outside use. This type of cord is designated with “WA” on the cord’s jacket.

Before using any extension cord, inspect it for loose or exposed wires and cut or worn insulation.

**Ampere rating (on tool data plate)

0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0

Cord Length

 

Wire Size (A.W.G.)

 

 

 

 

 

 

 

 

 

25'

16

16

16

16

14

14

 

 

 

 

 

 

 

50'

16

16

16

14

14

12

 

 

 

 

 

 

 

100'

16

16

14

12

10

**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge

WARNING:

Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools or other obstructions while you are working with a power tool. Failure to do so can result in serious personal injury.

WARNING:

Check extension cords before each use. If damaged replace immediately. Never use tool with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury.

7

Image 7
Contents Save this Manual for Future Reference OPERATOR’S ManualIntroduction WarrantyRead ALL Instructions General Safety Rules Blade Coasts After Being Turned OFF  Before Making a CUT, be Sure ALL ADJUST- Ments are Secure Specific Safety RulesSpecific Safety Rules Symbol Signal Meaning SymbolsExtension Cords ElectricalDouble Insulation Electrical ConnectionGlossary of Terms Dust BAG Bevel Lock Knob Blade Miter Wrench Fence Base FeaturesProduct Specifications Switch Trigger Lower Blade GuardBlade Wrench Storage Know Your Compound Miter SAWAMP Motor Bevel Lock KnobTools Needed Loose Parts Trace Holes AssemblyUnpacking Mounting HolesTighten To install the work clampDust BAG Work ClampAligning the Laser Guide Line Installing Batteries for LaserBatteries Compartment Cover Screw Laser Line Blade Bolt Cover Outer Blade To Install / Replace the BladeSee Figures 13 Spindle Lock ButtonView of Blade Square with Fence Squaring the SAW Blade to the FenceSee Figures 15 Socket Head Screws Fence MiterFence Indicator Screw Bevel Scale Miter Scale IndicatorSquare Table Miter Squaring the Blade to THE MITER TableSee Figures 19 Blade CombinationmiterCross CUT OperationApplications To Cross CUTBevel Scale IndicatorTo Bevel CUT See Figures 24See Figures 26 To Compound Miter CUTCompound Miter CUT 45 X 45 Compound Miter CUT Long Workpiece Workpiece Supports To Support Long WorkpiecesCutting Compound Miters COMPOUND-ANGLE Settings for Popular StructuresPitch Number of Sides Right SIDE, Outside Corner Miter Table Inside Fence Cutting Crown MoldingLaying Molding Flat on the Miter Table Ceiling FenceWrong Cutting Warped MaterialClamping Wide Workpieces See Figures 30Positive Stop Adjustments AdjustmentsPivot Adjustments Travel Pivot Adjustment Bevel Pivot AdjustmentLaser Assembly Laser Adjustment Screw To Adjust the Laser GuideBrush CAP Assembly MaintenanceGeneral Maintenance Brush ReplacementService Model NO. and Serial no