Advance 277V–480V (1) or (2) lamp 95W T5 VHO Ballast

Ballast Ordering, Electrical and Technical Data

 

 

Lamp

 

 

Maximum

 

 

Min.

No. of

Input

Starting

Ballast

Catalog

Input Power

Ballast

Line Current

Starting

Lamps

Volts

Method

Family

Number

ANSI (Watts)

Factor

(Amps)

Temp (˚F/˚C)

1

277

PS

Optanium

JOP-2S95-G

116W

1.1

0.42A

-19/-28

1

347

PS

Optanium

JOP-2S95-G

116W

1.1

0.35A

-19/-28

1

480

PS

Optanium

JOP-2S95-G

116W

1.1

0.24A

-19/-28

2

277

PS

Optanium

JOP-2S95-G

206W

1.0

0.74A

-19/-28

2

347

PS

Optanium

JOP-2S95-G

206W

1.0

0.59A

-19/-28

2

480

PS

Optanium

JOP-2S95-G

206W

1.0

0.43A

-19/-28

Above specifications subject to change without notice.

Features

• Programmed Start ballast

-19˚F (-28˚C) minimum starting temperature

• Ballast factor of 1.0 for 2-lamp version

• <10% Total Harmonic Distortion (THD)

277V–480V input voltage range, 50/60Hz

• One or two lamp operation

• 194˚F/ 90˚C maximum case temperature

 

General Specifications

Section I — Physical Characteristics

1.1The electronic ballast shall be furnished with integral leads color coded to ANSI standard C82.11.

Section II — Performance Requirements

2.1The electronic ballast shall be programmed start.

2.2The electronic ballast shall operate from 250V–528V.

2.3The electronic ballast shall maintain constant light output, for line voltage variations of 10% of rated supply voltage.

2.4The electronic ballast input current shall have Total Harmonic Distortion (THD) of less than 10% at maximum light output for primary lamps.

2.5The electronic ballast shall have a Power Factor greater than 98% at full light output.

2.6The electronic ballast shall have a minimum ballast factor of 1.0 for primary lamp applications.

2.7The electronic ballast lamp current crest factor shall be 1.7 or less in accordance with lamp manufacturer recommendation.

2.8The electronic ballast shall withstand a sustained open circuit and output conditions without damage.

2.9The electronic ballast shall be Sound Rated A.

2.10The electronic ballast shall be a high frequency electronic type and operate above 40 kHz to avoid interference with infrared control systems, and eliminate visible flicker.

2.11The electronic ballast shall comply with ANSI C82.11, where applicable.

2.12The electronic ballast shall provide transient immunity as specified in ANSI C62.41.

2.13The electronic ballast shall provide end of life protection circuitry.

2.14The electronic ballast shall have a minimum starting temperature of -19°F (-28°C) for T5VHO lamps.

Section III — Regulatory Requirements

3.1The electronic ballast shall not contain any Polycholorinated Biphenyl (PCB’s).

3.2The electronic ballast shall be Underwriters Laboratories (UL 935) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified, where applicable.

Section IV — Other

4.1The manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.

4.2The electronic ballast shall be produced in a factory certified to ISO 9001 Quality System Standards.

Wiring Diagram–Lamp Operation

Advance JOP-2S95-G T5 VHO for 2-lamp version ballast

LAMP

 

BLACK/ORANGE

 

RED

(HOT)

BALLAST

YELLOW

(NEUTRAL )

BLACK/WHITE

 

BLUE

Yellow leads must be connected for (1) lamp operation

Enclosure Dimensions

Advance JOP-2S95-G T5 VHO Ballast

A. . . . . . . 1.18"

B. . . . . . . 1.70"

C. . . . . . 16.34"

D. . . . . . 16.70"

(HOT) BLACK/ORANGE

(NEUTRAL ) BLACK/WHITE

LAMP

RED

BALLAST YELLOW

BLUE

LAMP

Image 3
Contents Lower the costs of your ceilings Lamp Ordering, Electrical and Technical Data 90% Lumen MaintenanceRated Average Life1 Wiring Diagram-Lamp Operation Ballast Ordering, Electrical and Technical DataFeatures General Specifications