Carrier 00EFN900003000A Accessory Package Contents, Refrigeration Piping Connections Material SI

Page 2

Table 2 — Accessory Package Contents

ACCESSORY PACKAGE

ITEM NO.

DESCRIPTION

PART NO.

QTY

PART NO.

 

 

 

 

 

1

Economizer shutoff valve - 11/8 in. (29 mm)

00PPG000023501A

2

 

2

Liquid line shutoff valve - 13/8 in. (35 mm)

EP71BA393

2

 

3

5 Wire jacketed cable

RM02EJ200

200 ft

 

(61 m)

 

 

 

 

 

4

Cable assembly

32GB404694

5

 

5

Junction box

HX30FZ001

2

 

6

Junction box cover

HX38ZZ001

2

00EFN900003000A

7

M6 Screws

00PPN500000302A

8

8

Cooler pipe flange - 31/8 in. (79 mm)

00PSN500091400A

2

 

 

10

Flex connector flange - 4 in. (102 mm)

00PSG000213300A

2

 

11

Loose pipe flange - 4 in. (102 mm)

00PSG000205100A

2

 

12

Cooler flange O-ring

KK71EW256

4

 

13

Flex connector flange O-ring

KK71EW250

2

 

14

Compressor flange gasket - 3 in. (76 mm)

00PPG000011702A

2

 

15

Compressor flange gasket - 4 in. (102 mm)

00PSG000011703A

4

 

16

Transducer wiring harness - 100 ft (30.5 m)

00PSN500180500A

2

 

1

Economizer shutoff valve - 11/8 in. (29 mm)

00PPG000023501A

2

 

2

Liquid line shutoff valve - 13/8 in. (35 mm)

EP71BA393

2

 

3

5 Wire jacketed cable

RM02EJ200

200 ft

 

(61 m)

 

 

 

 

 

4

Cable assembly

32GB404694

5

 

5

Junction box

HX30FZ001

2

 

6

Junction box cover

HX38ZZ001

2

00EFN900003100A

7

M6 Screws

00PPN500000302A

8

 

8

Flex connector flange O-ring

KK1EW250

2

 

9

Compressor flange gasket - 4 in. (102 mm)

00PSG000011703A

4

 

10

Compressor flange gasket - 5 in. (127 mm)

00PPG000011704A

4

 

11

Loose pipe flange - 5 in. (127 mm)

00PSG000211900A

2

 

12

Loose pipe flange - 4 in. (102 mm)

00PSG000205100A

2

 

13

Flex connector flange - 4 in. (102 mm)

00PSG000213300A

2

 

14

Transducer wire harness - 100 ft (30.5 m)

00PSN500180500A

2

Choose a space that can support the weight of the cooler and economizer with service clearances and area for refrigerant piping. Field-supplied piping must be limited to less than 50 lineal ft (15.25 m) or 75 equivalent ft (22 m) in length. Suction and liquid line risers must be limited to less than 15 ft (4.5 m) vertical riser elevation. Suction lines and economizer lines must be insulated to prevent condensation. Relocating the cooler introduces minimal line losses if correct piping practices are followed. Buried lines are not permitted.

The remote cooler system can be applied in three different configurations. See Fig. 1-3. In Fig. 1, the remote cooler and the outdoor unit are at the same elevation. The suction, liquid, and economizer lines run parallel between the cooler and the outdoor unit. In Fig. 2, the outdoor unit and remote cooler are at the same elevation, but the interconnecting piping has an ele- vation of up to 15 ft (4.5 m) above the base elevation of the cooler. This could be result of running piping over a wall or through the ceiling in a building. In Fig. 3, the remote cooler is located below the outdoor unit. The interconnecting piping has an elevation of up to 15 ft (4.5 m) above the base elevation of the remote cooler. This could occur if the remote cooler is in- stalled in a basement.

NOTE: Unit 30XA refrigeration piping can be either copper tubing or steel tubing with flanged connections. All units are

factory charged with compressor oil to the required level. However, when the double riser is constructed with U-bends or street elbows, a substantial amount of oil can be trapped in the U-bend during prolonged minimum load operation. If this occurs, additional oil is needed to add to the system to prevent the oil level from dropping below the minimum level in the oil separator. Add 1 gallon of oil to each circuit. Refer to Controls, Start-up, Operation, Service, and Troubleshooting Guide for recommended oil type.

Table 3A — Refrigeration Piping and

Connections Material (English)

PIPE SIZE (in.)

MATERIAL

5/8, 7/8, 11/8, 13/8, 15/8,

Refrigeration copper

21/8, 25/8, 31/8

 

2, 21/2, 3, 31/2, 4

Schedule 40 Steel

Table 3B — Refrigeration Piping and

Connections Material (SI)

PIPE SIZE (mm)

MATERIAL

16, 22, 29, 35, 41, 54, 67, 79

Refrigeration copper

51, 64, 76, 89, 102

Schedule 40 Steel

2

Image 2
Contents Installation Instructions Refrigeration Piping Connections Material SI Accessory Package ContentsRefrigeration Piping Connections Material English Liquid Line Economizer Line Suction LineInstallation Refrigeration Line Sizes SI Cooler and Economizer WeightsRefrigeration Line Sizes English 30XA080-120 Cooler Dimensions 30XA180-240 Cooler Dimensions 30XA090-160 Economizer Dimensions Typical Cooler Piping-Cooler Side View 30XA140, 160 Shown Remote Cooler and Economizers Installa Page Materials Required for Steel Piping Flange Connections Circuit a Circuit B 140134a Refrigerant Additional Refrigerant Charges RequiredCircuit a Circuit B 280 RED. TEE Reducing Tee 30XA080-120 All CircuitsConstruction Detail 30XA140-160 Circuit B STR ELLS- Street ElbowsFlange and Gasket Mounting Locations Thermistor Connections

00EFN900003000A specifications

The Carrier 00EFN900003000A is a cutting-edge heating, ventilation, and air conditioning (HVAC) unit designed to meet the varying demands of both residential and commercial applications. Its innovative features and advanced technologies make it a leader in energy efficiency and performance.

One of the main features of the Carrier 00EFN900003000A is its variable-speed compressor, which allows for precise temperature control. This technology enables the unit to adjust its output based on the specific cooling or heating needs of the space, ensuring optimal comfort and minimizing energy consumption. The variable-speed operation results in quieter performance as the system smoothly ramps up or down rather than operating at a constant speed.

This model is equipped with advanced refrigerant technology, utilizing environmentally friendly R-410A refrigerant. This hydrofluorocarbon (HFC) refrigerant is designed to reduce ozone depletion potential while maintaining high energy efficiency. The Carrier 00EFN900003000A includes high-efficiency coils that enhance heat exchange, boosting the system's overall performance and durability.

Another notable characteristic of the Carrier 00EFN900003000A is its integrated smart technology. This unit can be connected to modern smart home systems, allowing users to monitor and control their HVAC system from anywhere via smartphone applications. The ability to receive alerts for maintenance needs and system performance helps ensure that the unit operates at peak efficiency over its lifespan.

Design-wise, the Carrier 00EFN900003000A boasts a compact and lightweight structure, making it suitable for various installation scenarios, from tight residential spaces to larger commercial environments. Its robust build quality ensures longevity and reliability, even in harsh weather conditions.

Furthermore, the unit features a user-friendly interface that simplifies operation and programming. With programmable settings and adjustable fan speeds, users can easily customize their comfort levels while maximizing energy efficiency.

In summary, the Carrier 00EFN900003000A represents a significant advancement in HVAC technology, offering variable-speed operation, eco-friendly refrigerants, smart connectivity, and user-centric design. This model stands out as an ideal choice for consumers seeking energy efficiency and superior comfort in their indoor environments.