T10499 Circuit Requirements
This machine is prewired to operate on a 115V power supply circuit that has a verified ground and meets the following requirements:
Nominal Voltage | 115V |
Cycle | 60 Hz |
Phase | |
Power Supply Circuit | 15 Amps |
Plug/Receptacle | NEMA |
This machine is equipped with a power cord and plug that have an
GROUNDED
Grounding Prong
Neutral Hot
Figure 3. Typical 5-15 plug and receptacle.
T10500 Circuit Requirements
This machine is prewired to operate on a 230V power supply circuit that has a verified ground and meets the following requirements:
Nominal Voltage | 230V |
Cycle | 60 Hz |
Phase | |
Power Supply Circuit | 20 Amps |
Plug/Receptacle | NEMA |
The provided power cord and the plug specified above have an
GROUNDED |
Current Carrying Prongs |
Grounding Prong |
Figure 4. Typical 6-20 plug and receptacle.
SHOCK HAZARD!
No adapter should be used with the required plug. If the plug does not fit the available receptacle, or the machine must be reconnected for use on a different type of circuit, the reconnection must be made by a qualified electrician and comply with all local codes and ordinances.
T10499/T10500 Blade Welder |