Hitachi X200 manual Group Fine-tuning functions, Function Code Name Range Efce

Page 9

Function List

A Group: Standard functions

[X:: AllowedNot allowed ]

 

 

 

 

 

Default

 

 

Run mode

Function Code

 

Name

Range

-EF(CE)

-U(UL)

-R(JP)

Unit

 

edit

 

 

Frequency upper limit setting

 

 

Lo

Hi

 

A061

0.0/Freq. lower limit setting to maximum freq.

0.0

0.0

0.0

Hz

X

 

 

A261

Frequency upper limit setting, 2nd motor

0.0/Freq. lower limit setting (2nd) to maximum freq. (2nd)

0.0

0.0

0.0

Hz

X

 

 

A062

Frequency lower limit setting

0.0/Start freq. to freq. upper limit setting

0.0

0.0

0.0

Hz

X

 

 

A262

Frequency lower limit setting, 2nd motor

0.0/Start freq. (2nd) to freq. upper limit setting (2nd)

0.0

0.0

0.0

Hz

X

 

PID Control

A063

Jump (center) frequency setting 1

0.0 to 400.

0.0

0.0

0.0

Hz

X

 

A064

Jump (hysteresis) frequency setting 1

0.0 to 10.0

0.5

0.5

0.5

Hz

X

 

 

 

 

A065

Jump (center) frequency setting 2

0.0 to 400.

0.0

0.0

0.0

Hz

X

 

 

A066

Jump (hysteresis) frequency setting 2

0.0 to 10.0

0.5

0.5

0.5

Hz

X

 

 

A067

Jump (center) frequency setting 3

0.0 to 400.

0.0

0.0

0.0

Hz

X

 

 

A068

Jump (hysteresis) frequency setting 3PID Enable

0.0 to 10.0

0.5

0.5

0.5

Hz

X

 

 

A071

PID Enable

00(Disable)/01(Enable)

00

00

00

-

X

 

 

A072

PID proportional gain

0.2 to 5.0

1.0

1.0

1.0

-

 

 

 

A073

PID integral time constant

0.0 to 150.0

1.0

1.0

1.0

sec

 

 

PID Control

A074

PID derivative time constant

0.00 to 100.0

0.00

0.00

0.00

sec

 

 

A075

PV scale conversion

0.01 to 99.99

1.00

1.00

1.00

-

X

 

 

 

 

A076

PV source setting

00([OI] terminal)/01([O] terminal)/02(RS485)/10(Calculation result)

00

00

00

-

X

 

 

A077

Reverse PID action

00(OFF)/01(ON)

00

00

00

-

X

 

 

A078

PID output limit

0.0 to 100.0

0.0

0.0

0.0

%

X

 

 

A081

AVR function select

00(Enable)/01(Disable)/02(Enabled except during deceleration)

00

00

02

-

X

X

AVR function

A082

AVR voltage select

200V class: 200/215/220/230/240

200/400

200/400

200/400

V

X

X

 

400V class: 380/400/415/440/460/480

 

 

 

 

 

 

 

 

 

Automatic Energy

A085

Operation mode selection

00(Normal)/01(Energy-saver)

00

00

00

-

X

X

Saving

A086

Energy saving mode tuning

0.0 to 100.0

50.0

50.0

50.0

%

X

X

 

A092

Acceleration (2) time setting

0.01 to 99.99/100.0 to 999.9/1000. to 3000.

15.00

15.00

15.00

sec

 

 

 

A292

Acceleration (2) time setting, 2nd motor

0.01 to 99.99/100.0 to 999.9/1000. to 3000.

15.00

15.00

15.00

sec

 

 

 

A093

Deceleration (2) time setting

0.01 to 99.99/100.0 to 999.9/1000. to 3000.

15.00

15.00

15.00

sec

 

 

 

A293

Deceleration (2) time setting, 2nd motor

0.01 to 99.99/100.0 to 999.9/1000. to 3000.

15.00

15.00

15.00

sec

 

 

 

A094

Select method to switch to Acc2/Dec2 profile

00(2CH from input terminal)/01(transition freq.)

00

00

00

-

X

X

Operation mode and

A294

Select method to switch to Acc2/Dec2 profile, 2nd motor

00(2CH from input terminal)/01(transition freq.)

00

00

00

-

X

X

acc./dec. function

A095

Acc1 to Acc2 frequency transition point

0.0 to 400.0

0.0

0.0

0.0

Hz

X

X

 

A295

Acc1 to Acc2 frequency transition point, 2nd motor

0.0 to 400.0

0.0

0.0

0.0

Hz

X

X

 

A096

Dec1 to Dec2 frequency transition point

0.0 to 400.0

0.0

0.0

0.0

Hz

X

X

 

A296

Dec1 to Dec2 frequency transition point, 2nd motor

0.0 to 400.0

0.0

0.0

0.0

Hz

X

X

 

A097

Acceleration curve selection

00(Linear)/01(S-curve)

00

00

00

-

X

X

 

A098

Deceleration curve selection

00(Linear)/01(S-curve)

00

00

00

-

X

X

 

A101

[OI]-[L] input active range start frequency

0.0 to 400.0

0.0

0.0

0.0

Hz

X

 

 

A102

[OI]-[L] input active range end frequency

0.0 to 400.0

0.0

0.0

0.0

Hz

X

 

External freq. tuning

A103

[OI]-[L] input active range start current

0. to 100.

0.

0.

0.

%

X

 

 

A104

[OI]-[L] input active range end current

0. to 100.

100.

100.

100.

%

X

 

 

A105

[OI]-[L] input start frequency enable

00(Use setting value)/01(0Hz)

01

01

01

-

X

 

 

A141

A input select for calculate function

00(Digital operator)/01(Keypad potentiometer)

01

01

01

-

X

 

 

A142

B input select for calculate function

02(O input)/03(OI input)/04(RS485)

02

02

02

-

X

 

 

A143

Calculation symbol

00(A141+A142)/01(A141-A142)/02(A141*A142)

00

00

00

-

X

 

 

A145

ADD frequency

0.0 to 400.0

0.0

0.0

0.0

Hz

 

 

Frequency

A146

ADD direction select

00(Plus)/01(Minus)

00

00

00

-

X

 

caluculation

A151

Pot. input active range start frequency

0.0 to 400.0

0.0

0.0

0.0

Hz

X

 

 

A152

Pot. input active range end frequency

0.0 to 400.0

0.0

0.0

0.0

Hz

X

 

 

A153

Pot. input active range start current

0.0 to 100.0

0.0

0.0

0.0

%

X

 

 

A154

Pot. input active range end current

0.0 to 100.0

100.

100.

100.

%

X

 

 

A155

Pot.input start frequency enable

00(Use offect (A151 value))/01(Use 0Hz)

01

01

01

-

X

 

b Group: Fine-tuning functions

[X:: AllowedNot allowed ]

 

 

 

 

 

Default

 

 

Run mode

Function Code

 

Name

Range

-EF(CE)

-U(UL)

-R(JP)

Unit

 

edit

 

 

 

 

 

Lo

Hi

 

b001

Selection of automatic restart mode

00(Alarm output)/01(Restart at 0Hz)/

00

00

00

-

X

 

 

02(Resume after freq. matching)/03(Resume freq. matching then trip)

 

 

 

 

 

 

 

 

 

 

 

b002

Allowable under-voltage power failure time

0.3 to 25.0

1.0

1.0

1.0

sec

X

 

 

b003

Retry wait time before motor restart

0.3 to 100.0

1.0

1.0

1.0

sec

X

 

 

b004

Instantaneous power failure / under-voltage trip

00(Disable)/01(Enable)

00

00

00

-

X

 

 

alarm enable

 

 

 

 

 

 

 

 

 

 

Restart after

b005

Number of restarts on power failure / under-voltage

00(Restart 16 times)/01(Always restart)

00

00

00

-

X

 

trip events

 

instantaneous power

 

 

 

 

 

 

 

 

 

Start frequency to be used in case of frequency

 

 

 

 

 

 

 

failure

b011

00(frequency at previous shutoff)/01(Max. Hz)/02(Set frequency)

00

00

00

-

X

X

pull-in restart

 

 

 

 

 

 

 

 

 

 

b012

Electronic thermal setting

 

Rated current

A

X

 

 

 

 

0.2*Rated current to 1.0*Rated current

 

 

 

 

 

 

 

b212

Electronic thermal setting, 2nd motor

 

Rated current

A

X

 

 

b013

Electronic thermal characteristic

00(Reduced torque)/01(Constant torque)/02(Reduced torque 2)

01

01

00

-

X

 

 

b213

Electronic thermal characteristic, 2nd motor

01

01

00

-

X

 

 

 

 

 

b021

Overload restriction operation mode

00(Disable)/01(Enable)/02(Enable for during acceleration)

01

01

01

-

X

 

 

b221

Overload restriction operation mode, 2nd motor

01

01

01

-

X

 

 

 

 

 

b022

Overload restriction setting

0.2*Rated current to 1.5*Rated current

1.5*Rated current

A

X

 

 

b222

Overload restriction setting, 2nd motor

A

X

 

 

 

 

 

 

 

 

b023

Deceleration rate at overload restriction

0.1 to 3000.0

1.0

30.0

1.0

sec

X

 

Overload restriction

b223

Deceleration rate at overload restriction, 2nd motor

1.0

30.0

1.0

sec

X

 

 

 

 

b028

Overload restriction source selection

00(b022/b222 setting level)/01([O]-[L] analog input)

00

00

00

-

X

 

 

b228

Overload restriction source selection, 2nd motor

00

00

00

-

X

 

 

 

 

 

b029

Deceleration rate of frequency pull-in restart

0.1 to 3000.0

0.5

0.5

0.5

sec

X

X

 

b030

Current level of frequency pull-in restart

0.2*Rated current to 2.0*Rated current

Rated current

A

X

X

 

 

 

00([SFT] input blocks all edits)/01([SFT] input blocks edits except

 

 

 

 

 

 

Lock

b031

Software lock mode selection

F001 and Multispeed parameters/02(No access to edits)/03(No

01

01

01

-

X

 

access to edits except F001 and Multi-speed parameters)/10(High-

 

 

 

 

 

 

 

 

 

 

 

 

 

level access,including b031)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Image 9
Contents Page Page Page Phase 200V class Standard SpecificationsPhase 400V class General SpecificationsInches for reference only Dimensions Operation and Programming Operation / Terminal Functions Hardware switchesTerminal Description Control circuit terminalsFunction List Monitoring and main profile parametersX Not allowedGroup Standard functions Function Code Name Range Efce Group Fine-tuning functionsGroup Intelligent terminal functions How to access the details about the present fault Error CodesProtective Functions Group Motor constants functionsX Not allowedConnecting Diagram Source type logicDynamic breaking umit BRD Sink type logic Wiring and Accessories Torque characteristics/Derating Curves Torque characteristicsDerating Curves Application to Motors For Correct OperationPrecaution for Correct Usage Main power supplyHigh-frequency Noise and Leakage Current Lifetime of Primary PartsMemo Memo