Powermatic 75 Receiving, Installation and Assembly, Electrical Connection, Box contents

Page 8

RECEIVING

Remove all contents from the shipping carton and check each item against the packing list. Report any missing or damaged parts immediately to your ship- ping agent and distributor. Read the instruction manual thoroughly for assembly, alignment, maintenance and safety instructions.

Box contents:

 

 

1

impeller housing with motor

2

housings

1

hose adapter

4

retainer straps

1

8"-6" adapter

1

support plate

4

clear (lower) bags

2

extension plates

2

cloth (upper) bags

4

support legs

2

upper hangers

2

support brackets

2

lower hangers

2

rubber gaskets

 

 

1hardware bag containing: 4 casters, 2 hanger brack- ets, nuts, screws, washers.

INSTALLATION AND ASSEMBLY

Use the exploded view on page 14 to assist with the following instructions:

1.Turn the base (18) on edge and screw the four casters (21) into the threaded holes. Secure with nuts (40) and lock washers (45).

2.Attach the two end extension plates (19) with the hex head screws (32) and nuts (38) with lock washer (46) and flat washer (43).

3.Mount the support plate (20) to both sides of base using hex head screws (32) with flat washers (43), lock washers (46), and nuts (38).

4.Mount the two support brackets (15) to the base and support plate using the hex head screws (32) and flat washers (43). NOTE: Be careful that you do not strip the screws.

5.If shipped unassembled, mount the motor (22), shaft key (25), and gasket (26) to the underside of the impeller housing (1), and lock down on the topside with nuts (39), lock washers (44), and flat washers (42).

6.With the aid of an assistant, mount the impeller housing (with attached motor) to the support brackets (15) aligning the holes of the four housing bolts and securing with nuts (38), lock washers (46) and flat washers (43).

7.Screw the impeller (3) on to the threaded motor shaft and be sure to install the shaft key (25) at the same time. Tighten down with nut (37) and washer (41).

8.Install the housing gasket (4) and inlet cover (5) to the housing using the round head sheet metal screws (31).

9.Attach both side housing units (2) with rubber gaskets (30) to the impeller housing using the hex head screws (32), washers (43), and nuts (38).

10.Attach the four leg supports (14) first to the base

(18) with hex head screws (32), washers (43), lock washers (46) and nuts (38). Next, attach the top sec- tion of the hanger brackets to the side housing units with hex head screws (32), washers (43), lock wash- ers (46) and nuts (38).

NOTE: As shown in the exploded view, one bracket on either side is mounted to the side housing with a hanger bracket (11). Be sure to install hanger bracket during assembly at this time.

ACCESSORIES ATTACHMENT

Dust Bags & Hose

1.Screw upper hanger into lower hanger (9 & 10) and secure with large nut (38). Attach this assembly to the hanger bracket (11).

2.Install the lower (17) and upper (8) dust bags with the straps provided making sure they are securely fas- tened with no air leaks.

!CAUTION: Retainer straps are rolled up under tension. Hold strap with hand and allow it to unroll gradually.

3.Choose the hose adapter (7 or 53) according to your particular requirements and attach the accesso- ries as shown.

ELECTRICAL CONNECTION

The dust collector is equipped with a 3 HP, single phase, 230 volt or three phase, 230/460 volt motor. The unit is factory wired for 230 volts and equipped with a 20 amp cord and plug set. The 230 volt plug requires a receptacle as illustrated in Figure 1. The three phase motor may be reconnected for 460 volts by changing the connections as illustrated in the diagram motor wiring box. The three phase power cord is not equipped with a plug.

8

Image 8
Contents Dust Collector Warranty & Service Table of Contents Safety Rules Page Safety Specifications Model 66, 10 Table Saw Installation and Assembly Box contentsReceiving Electrical ConnectionOperation All grounded, cord connected toolsMaintenance Stop and removing plug from power sourceTrouble-Shootingfor Model 75 Dust Collector Parts List Model 75 Dust Collector Description Quantity6286612 Model 75 Dust Collector Page 07/01