Bostitch 102272REVB 3/97 manual T40 Tool Specifications

Page 9

T40 TOOL SPECIFICATIONS

All screws and nuts are metric.

TOOL AIR FITTING:

This tool uses a 1/4” N.P.T. male plug. The inside diameter should be .200” (5mm) or larger. The fitting must be capable of discharging tool air pressure when disconnected from the air supply.

OPERATING PRESSURE:

70 to 100 p.s.i.g. (4.9 to 7.0 kg/cm2). Select the operating pressure within this range for best fastener performance.

DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.

AIR CONSUMPTION:

The T40 requires 2.6 cubic feet per minute (73.6 liters per minute) of free air to operate at the rate of 100 staples per minute, at 80 p.s.i. (5.6 kg/cm2). Take the actual rate at which the tool will be run to determine the amount of air required. For instance, if your fastener usage averages 50 staples per minute, you need 50% of the 2.6 c.f.m. (73.6 liters per minute) which is required to operate the tool at 100 staples per minute.

OPERATION

STANLEY-BOSTITCH OFFERS THREE TYPES OF OPERATION FOR THIS SERIES TOOL

CONTACT TRIP

The common operating procedure on “Contact Trip” tools is for the operator to contact the work to actuate the trip mechanism while keeping the trigger pulled, thus driving a fastener each time the work is contacted. This will allow rapid fastener placement on many jobs, such as sheathing, decking and pallet assembly.

All pneumatic tools are subject to recoil when driving fasteners. The tool may bounce, releasing the trip, and if unintentionally allowed to recontact the work surface with the trigger still actuated (finger still holding trigger pulled) an unwanted second fastener will be driven.

SEQUENTIAL TRIP

The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger. This makes accurate fastener placement easier, for instance on framing, toe nailing and crating applications.

The Sequential Trip allows exact fastener location without the possibility of driving a second fastener on recoil, as described under “Contact Trip”.

The Sequential Trip Tool has a positive safety advantage because it will not accidentally drive a fastener if the tool is contacted against the work – or anything else – while the operator is holding the trigger pulled.

TRIGGER OPERATED

The Trigger Operated model is cycled by actuation of the trigger only. This model does not have a Contact Arm and is intended for use only where a Contact Arm CANNOT be used to satisfy the requirements of the application. The Trigger Operated tool will cycle each time the trigger is actuated.

MODEL IDENTIFICATION:

Refer to Operation Instructions on page 4 before proceeding to use this tool.

CONTACT TRIP

SEQUENTIAL TRIP

TRIGGER OPERATED

Identified by:

Identified by:

Identified by:

BLACK TRIGGER

GRAY TRIGGER

BLACK TRIGGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-9-

Image 9
Contents T40M Limited Warranty IntroductionIndex AIR Supply and Connections Safety InstructionsLoading Tool OperationTrigger Operation Tool OperationContact Trip Operation Sequential Trip OperationTrigger Operated Tool Tool Operation CheckBasic Tool Operation Trouble Shooting Problem Cause CorrectionCoil Nailers Lubrication T40 Tool Specifications Loading the T40M Tools Fastener SpecificationsQuick Release Door Cleaning T40S2 Staplers Used with Asphalt Shingles T40WBK Accessories Available