Carrier 25VNA owner manual Using Your NEW Carrier System, Infinity Variable Speed Operation

Page 1

25VNA

Infinityt Variable Speed Heat Pump with Greenspeedt Intelligence

2 to 5 Nominal Tons

Owner’s Manual

A NOTE ABOUT SAFETY

Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:

DANGER identifies the most serious hazards which will result in severe personal injury or death.

WARNING signifies hazards that could result in personal injury or death.

CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

!WARNING

PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or property damage.

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory-authorized kits or accessories when modifying this product.

Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new heat pump.

ABOUT YOUR HEAT PUMP SYSTEM Identifying Your System

Your new Carrier heat pump system is what we call a ”split system.” It has an outdoor unit and an indoor unit connected to each other with copper tubing called refrigerant lines. Each of these units has a rating plate with the model and serial numbers you will need to reference when calling an authorized Carrier dealer about your system.

Take a few moments now to locate those numbers and record them in the spaces provided on the cover of this booklet.

USING YOUR NEW CARRIER SYSTEM

Your Carrier heat pump system is controlled by a wall-mounted Infinity Control installed inside your home. This system requires an Infinity Control which has software designed specifically to operate this system. See the Infinity Control Homeowner Guide for more details on system operation.

INFINITY VARIABLE SPEED OPERATION

You may notice your system runs for longer periods of time. This system is designed to meet cooling or heating needs of the home at a wide range of conditions. Your indoor temperature will remain more consistent with fewer drafts, better humidity control, enhanced comfort and enhanced energy efficiency.

HEATING AND COOLING YOUR HOME

For heating or cooling operation, make sure the System or Mode control is set to the appropriate mode. Then, adjust the Temperature control to your desired setting. Finally, use the Fan control to select Automatic (turns on and off as heating is needed) or On (runs continuously).

Depending on your typical heating needs, your home comfort system may also include a supplementary heating source that will automatically turn on as needed. You may also select this heat source manually if desired.

OPERATION UNDER EXTREME

CONDITIONS

Your heat pump will run as long as necessary to maintain the indoor temperature selected on your Infinity Control. On extremely hot days, your heat pump will run for longer periods at a time than on moderate days. Your system will also run for longer periods of time under the following conditions:

SFrequent opening of exterior doors S Operating laundry appliances

S Taking hot showers

S More than the usual number of people present in the home S More than the normal number of electric lights in use

S Drapes or blinds are open on the sunny side of the home

IMPORTANT HEAT PUMP FACTS

Heat pump systems have a few unique features and operations that you should be aware of:

SDuring the heating cycle, your heat pump delivers a constant flow of air at around 95° to about 105° F, compared to sudden blasts of hot air provided by a typical furnace.

SIce or frost may form on the outdoor coil during winter heating operation. Your heat pump will automatically melt the ice us- ing its defrost cycle. During defrost, you may see steam or fog rising from the outdoor unit, which is normal. At the beginning and end of the defrost cycle, you may hear a "whoosh" sound coming from the unit. This is normal for heat pump applications.

SHeat pumps installed in areas expecting snow are elevated with support feet.

Image 1
Contents Infinity Variable Speed Operation Using Your NEW Carrier SystemHeating and Cooling Your Home Operation Under Extreme ConditionsSEA Coast Coil Maintenance Routine MaintenanceTroubleshooting SoundRegular Dealer Maintenance Catalog NoOM25VNA---01

25VNA specifications

The Carrier 25VNA is a highly efficient and advanced variable-speed air conditioning system designed to provide optimal comfort and performance for residential applications. Known for its innovative technologies and superior energy efficiency, the 25VNA is engineered to meet the diverse needs of homeowners while minimizing environmental impact.

One of the standout features of the Carrier 25VNA is its variable-speed compressor. This cutting-edge technology allows the system to adjust its cooling output in real time, providing precise temperature control and enhancing comfort throughout the home. The variable-speed operation means that the system can run at lower speeds for longer periods, ensuring a more consistent indoor environment while using less energy. This results in significant energy savings on utility bills while also contributing to a reduced carbon footprint.

In addition to its variable-speed compressor, the Carrier 25VNA incorporates advanced refrigerant technologies. It utilizes the environmentally friendly Puron refrigerant, which not only meets regulatory requirements but also enhances the system's overall efficiency. This refrigerant aids in maintaining optimal heat transfer rates, ensuring that the system operates at peak performance.

Another notable characteristic of the 25VNA is its robust design and construction. The unit features a weather-resistant cabinet that is built to withstand harsh outdoor conditions while remaining visually appealing. The durable construction not only prolongs the system's lifespan but also reduces the need for frequent maintenance.

The Carrier 25VNA is equipped with a comprehensive set of smart features to enhance user experience. The system is compatible with Carrier's Infinity Touch Control, allowing users to manage their HVAC settings remotely through a smartphone application. This connectivity provides ease of use and enables homeowners to monitor their energy usage, adjust temperature settings, and receive maintenance alerts right from their devices.

Noise reduction technology is another key component of the 25VNA. The system operates at extremely low sound levels, making it one of the quietest options available in the market. This is particularly beneficial for those who prioritize a peaceful home environment.

Overall, the Carrier 25VNA air conditioning system embodies efficiency, comfort, and smart technology. With its variable-speed compressor, eco-friendly refrigerant, durable construction, and innovative controls, it stands out as an excellent choice for homeowners seeking to enhance their indoor climate while reducing energy consumption and costs.