Harbor Freight Tools 98622 manual Extension Cords, Symbology, Safety Setup, Operation Maintenance

Page 7

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either

a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. (See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in

Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

Table A: RECOMMENDED MINIMUM WIRE

GAUGE FOR EXTENSION CORDS* (120/240 VOLT)

NAMEPLATE

 

EXTENSION CORD

AMPERES

 

 

LENGTH

 

(at full load)

25´

 

50´

75´

100´

150´

0 – 2.0

18

 

18

18

18

16

2.1

– 3.4

18

 

18

18

16

14

3.5

– 5.0

18

 

18

16

14

12

5.1

– 7.0

18

 

16

14

12

12

7.1 – 12.0

18

 

14

12

10

-

12.1

– 16.0

14

 

12

10

-

-

16.1

– 20.0

12

 

10

-

-

-

*Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

Safety

Setup

Symbology

 

Double Insulated

 

 

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

 

Edison Testing Labs

 

 

V

Volts

 

~Alternating Current

A

Amperes

 

n0 xxxx/min. No Load Revolutions per Minute (RPM)

WARNING marking concerning Risk of Eye Injury. Wear ANSI‑approved safety goggles with side shields.

Read the manual before set-up and/or use.

WARNING marking concerning Risk of Fire.

Do not cover ventilation ducts. Keep flammable objects away. WARNING marking concerning Risk of Electric Shock.

Properly connect power cord to appropriate outlet.

Operation

Maintenance

Item 98622

For technical questions, please call 1-800-444-3353.

Page 7

Image 7
Contents Page Table of Contents Personal safety General Power Tool Safety WarningsWork area safety Electrical safetyOperation Maintenan Safet SetuVibration Safety Double Insulated Tools Tools with Two Prong Plugs Grounded Tools Tools with Three Prong PlugsGrounding Extension Cords SymbologySafety Setup Operation MaintenanceSafet SpecificationsSetup Before Use FunctionsOperating Instructions Tool Set UpWorkpiece and Work Area Set Up General Operating InstructionsProblem Possible Causes Likely Solutions Cleaning, Maintenance, and LubricationTroubleshooting Maintenance and ServicingParts List and Diagram Safety Setup Operation MaintenancePart Description ’ty Please Read the Following Carefully Limited 90 Day Warranty