SPECIFICATIONS
Horizontal Range. . | . Up to 70 ft. (21 m); 100 ft. |
| (30.5 m) with Range Boost. |
| [varies with surrounding |
| temperature] |
Vertical Range. . . | . Up to 15 ft. (4.6 m) |
Sensing Angle. . . | . Up to 240° horizontal. Up to 80° |
| Vertical |
Electrical Load. . . | . Up to 300 Watt Maximum Tung- |
| sten Halogen [Up to 150 Watt |
| Maximum each bulb holder.] |
Power Requirements. 120 VAC, 60 Hz | |
Operating Modes. . | . TEST, AUTO, and MANUAL |
| MODE |
Time Delay . . . . | . 1, 5, 20 minutes |
Replacement bulb. . | T3, 150W halogen maximum |
| 120 VAC |
DualBrite® Timer. . | . Off, 3, 6 hours, |
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | |
|
| |
Lights will | 1. Light switch is turned off. | |
not come on. | 2. | Light is loose or burned out. |
| 3. | Fuse is blown or circuit breaker is |
|
| turned off. |
| 4. | Daylight |
|
| after dark). |
| 5. | Incorrect circuit wiring, if this is a new |
|
| installation. |
| 6. | |
|
| area. |
Lights come | 1. | Light control may be installed in a |
on in day- |
| relatively dark location. |
light. | 2. | Light control is in TEST. (Set control |
| ||
|
| switch to an |
|
| |
Lights come | 1. Light control may be sensing small | |
on for no |
| animals or automobile traffic. |
apparent |
| sensor). |
reason. | 2. RANGE is set too high. (Reduce | |
|
| RANGE). |
| 3. | DualBrite® Timer is on. |
Lights turn | 1. Sensor is in a relatively dark location. | |
off too late |
| (Relocate sensor, or use 3 hr or 6 hr |
in |
| setting). |
Dawn setting. |
|
|
|
|
|
SYMPTOM | POSSIBLE CAUSE | |
|
| |
Lights stay | 1. A bulb is positioned too close to the | |
on continu- |
| sensor or pointed at nearby objects |
ously. |
| that cause heat to trigger the sensor. |
|
| (Reposition the bulb away from the |
|
| sensor or nearby objects). |
| 2. | Sensor is pointed toward a heat source |
|
| like an air vent, dryer vent, or brightly- |
|
| painted |
|
| sition sensor. Reduce RANGE). |
| 3. | Light control is in Manual Mode.(Switch |
|
| to Auto). |
|
|
|
Lights flash | 1. | Heat or light from the bulbs may be |
on and off. |
| turning the light control on and off. |
|
| |
|
| (Reposition the bulbs away from the |
|
| sensor). |
| 2. | Heat being reflected from other objects |
|
| may be affecting the sensor. (Reposi- |
|
| tion sensor). |
| 3. | Light control is in the TEST mode and |
|
| warming up. (Flashing is normal under |
|
| these conditions. Turn BOOST off). |
|
|
|
Lights flash | 1. | Sensor is detecting its own lights. |
once, then |
| (Reposition bulbs to keep area below |
stay off in |
| the sensor relatively dark). |
Manual Mode. |
|
|
|
|
|