Items | Models |
247587 | |
247583 |
Twin Halogen Light
Questions or problems? Before returning to your retailer, call our technical service department at
Package Contents
• | Twin halogen light | • | Mounting strap |
• | Rubber plug | • | Gasket |
• | Wire connectors | • | Plastic hanger |
• | Mounting hardware | • | 2 Bulbs (installed) |
Installation Instructions
Estimated Installation Time: 30 minutes
Items needed for installation (not included):
• Phillips and flathead screwdrivers
• | Pliers | • | Wire strippers/cutters |
• | Safety glasses | • | Silicone caulk |
• | Ladder |
|
|
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician if there is any ques- tion as to the suitability of the system.
WARNING: Turn power off at the circuit breaker or fuse.
1.For easy installation, select an existing light that is operated by a wall switch for replacement.
Wiring and Final Assembly
2.Put the gasket in place before connecting wires.
(A)
(B)
(C)
Shields
3.Connect the fixture wires to the junction box wires (black to black, white to white, and junction box ground wire to green ground screw on fixture.). Secure with wire connectors provided.
4.Make sure the wire connectors and wires are inside the junction box. Secure the fixture with the screws provided.
5.If not installed on a weatherproof box or if an adaptor plate was used, caulk the wall plate and mounting surface with silicone weather sealant.
CAUTION to avoid fire or burn hazards:
•Allow fixture to cool before touching.The bulbs and fixture operate at high temperatures.
•Keep fixture at least 2" from combustible materials. Do not aim at objects closer than 3 feet.
•Replace bulbs with T4 100W (max.) G8 type halogen
6.Adjust the bulb holders by loosening the lock nuts (A) and/or lock screws (B) but do not rotate the bulb holders more than 180˚ from the factory setting. Tighten the lock nuts and lock screws after adjusting the fixture.
7.To adjust shields, loosen set screws (C) and turn shield coun- terclockwise about 1/3 turn and remove shield. Reinstall shield and turn clockwise to desired position. Tighten set screw (C).
8.To replace bulbs, remove shields as above. Line up bulb pins with bulb socket holes. Carefully push bulbs straight in. Bulbs are quite fragile and can be easily broken if side pressure is applied.
9.Replace bulb shields.
10.Turn on the circuit breaker and light switch.
Black | White |
|
Mounting Strap | Gasket | Rubber |
| Plug | |
|
|
Junction Box | Mounting |
Bolt |
Junction box ground wire to green ground screw on fixture.
© 2007 HeathCo LLC | |
| 598- - |