Installation Instructions
Without Two Piece Arm
Estimated Installation Time: 45 minutes
Items needed for installation (not included):
•Phillips and flathead screwdrivers
•13 mm, 10 mm, and 8 mm sockets
• | 3/16" Drill bit | • | Drill |
• | Pliers | • | Wire strippers/cutters |
• | Safety glasses | • | Silicone caulk |
• | Ladder | • | Small box or rag |
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suit- ability of the system.
Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.
WARNING: Turn power off at the circuit breaker or fuse.
1.Select a location on a flat wall with structurally sound wood and from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should be at least one inch (25 mm) thick to safely secure the fixture.
2.The fixture can be mounted with three lag screws and washers which are provided.
3.Using the mounting template as a guide, mark three mounting holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the lag screws.
4.Install the bottom two lag screws first. Screw in the lag screws so that there is about 3/8" (9.5 mm) of space under the head.
5.Place the fixture on these two lag screws and install the top lag screw. Tighten the top lag screw first, then tighten the remaining lag screws
6.Secure your outdoor cable or flexible conduit to the cover plate with a fitting in accordance with the National Electrical Code (Canadian Electrical Code in Canada).
7.Thread the black and white fixture wires through the hole in the cover plate as shown.
8.Connect the fixture wires to the service wires using the wire nuts provided (black to black and white to white).
9.This fixture must be grounded. Connect the service ground under the head of the green ground screw and secure to the fixture.
10.Install the cover plate. Secure with the two screws, two nuts and four washers provided.
11.Install the lens/reflector assembly with two screws and washers provided.
12.Screw in the 100 watt H.P. Sodium type S54 bulb provided.
13.Loosen the screw in the center of the photocontrol socket two turns. Twist the socket so that the arrow points north. Note: There is a stop to prevent the socket from turning all the way around. If you have trouble turning the socket, try turning it the other direction. Retighten the screw in the center of the socket.
14.Align the photocontrol (it will only
To test operation during the daytime, cover the photocontrol with a small box or rag. Turn the power on. Light should turn on and reach full brightness within ten minutes. Remove the box or rag to expose the photocontrol to daylight. Light should turn off within two minutes. With the photocontrol exposed, the light will operate automatically – on at dusk and off at dawn.
Photocontrol
Lag Screw (3)
Mounting
Plate
Ground
Screw
Cover
Plate
Lens/Reflector
Assembly
Bulb
Flat Washer (9)
Package Contents and Fixture Assembly