DEEPCELL SURFACE DPB2S16LS26U OR 22U
Page 2 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 16 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12
PHOTOMETRY
MODEL NO. DPB2S16LS26U120SO coefficients of utilization — zonal cavity method
| RF |
| 20 |
|
| 20 |
|
| 20 |
| |
| RC |
| 80 |
|
| 50 |
|
| 30 |
| |
| RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 | |
| 1 | 60 | 58 | 57 | 55 | 54 | 52 | 53 | 52 | 51 | |
ratio | 2 | 56 | 52 | 50 | 50 | 47 | 45 | 48 | 46 | 44 | |
3 | 52 | 47 | 44 | 45 | 42 | 40 | 43 | 41 | 39 | ||
cavity | 4 | 48 | 43 | 38 | 41 | 37 | 35 | 39 | 37 | 34 | |
5 | 45 | 38 | 34 | 37 | 33 | 31 | 36 | 33 | 30 | ||
room | 6 | 41 | 35 | 31 | 34 | 30 | 27 | 33 | 30 | 27 | |
7 | 39 | 32 | 28 | 31 | 27 | 25 | 30 | 27 | 24 | ||
| |||||||||||
| 8 | 36 | 29 | 25 | 28 | 25 | 22 | 28 | 24 | 22 | |
| 9 | 34 | 27 | 23 | 26 | 23 | 20 | 26 | 22 | 20 | |
| 10 | 32 | 25 | 21 | 24 | 21 | 18 | 24 | 21 | 18 |
visual comfort probability
room size |
|
|
|
| ceiling height |
|
|
|
| ceiling height |
| ||
W | L |
| 8.5 | 10.0 | 13.0 | 16.0 |
|
| 8.5 | 10.0 | 13.0 | 16.0 | |
20 | 20 |
|
| 81 | 74 | 70 | 74 |
|
| 80 | 72 | 66 | 74 |
20 | 30 |
|
| 82 | 76 | 72 | 70 |
|
| 81 | 74 | 69 | 68 |
20 | 40 |
|
| 84 | 78 | 75 | 72 |
|
| 83 | 76 | 72 | 70 |
20 | 60 |
|
| 85 | 80 | 77 | 74 |
|
| 84 | 78 | 74 | 72 |
30 | 20 |
|
| 84 | 79 | 72 | 73 |
|
| 83 | 77 | 69 | 74 |
30 | 30 |
|
| 85 | 80 | 74 | 70 |
|
| 84 | 78 | 71 | 68 |
30 | 40 |
|
| 86 | 81 | 76 | 72 |
|
| 85 | 80 | 74 | 70 |
30 | 60 |
|
| 86 | 82 | 78 | 74 |
|
| 86 | 81 | 76 | 72 |
30 | 80 |
| lengthwise | 87 | 83 | 79 | 76 |
| crosswise | 86 | 82 | 77 | 74 |
40 | 40 |
| 87 | 83 | 79 | 73 |
| 87 | 82 | 77 | 72 | ||
40 | 20 |
|
| 86 | 81 | 75 | 74 |
|
| 85 | 79 | 73 | 75 |
40 | 30 |
| luminaries | 87 | 82 | 77 | 71 |
| luminaries | 86 | 80 | 75 | 70 |
40 | 60 |
| 87 | 84 | 80 | 74 |
| 87 | 83 | 78 | 73 | ||
40 | 80 |
|
| 88 | 84 | 81 | 76 |
|
| 87 | 84 | 79 | 75 |
40 | 100 |
|
| 88 | 85 | 82 | 77 |
|
| 87 | 84 | 81 | 77 |
60 | 30 |
|
| 87 | 83 | 78 | 74 |
|
| 86 | 82 | 76 | 73 |
60 | 40 |
|
| 88 | 84 | 80 | 75 |
|
| 87 | 83 | 78 | 74 |
60 | 60 |
|
| 88 | 85 | 81 | 76 |
|
| 87 | 84 | 79 | 75 |
|
| ||||||||||||
60 | 80 |
|
| 88 | 85 | 82 | 78 |
|
| 87 | 84 | 81 | 77 |
60 | 100 |
|
| 88 | 85 | 83 | 79 |
|
| 88 | 85 | 82 | 78 |
100 | 40 |
|
| 88 | 84 | 81 | 77 |
|
| 87 | 83 | 79 | 76 |
100 | 60 |
|
| 88 | 85 | 82 | 78 |
|
| 88 | 84 | 81 | 77 |
100 | 80 |
|
| 88 | 86 | 83 | 79 |
|
| 88 | 85 | 82 | 78 |
100 | 100 |
|
| 88 | 86 | 84 | 80 |
|
| 88 | 85 | 83 | 79 |
ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S16LS26U120SOGLR
DP |
|
| B |
|
| 2 |
| |||
|
|
|
|
|
|
|
|
|
|
|
DEEPCELL |
|
|
|
|
| FIXTURE |
| |||
PARABOLIC: |
|
|
|
|
| WIDTH |
| |||
|
|
|
|
|
|
|
| |||
Aluminum |
|
|
|
|
|
|
|
| ||
Louver |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
| BODY STYLE: |
|
|
|
| |||
|
|
|
| Surface Box |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
*Consult factory for availability of louver finishes.
| S |
| 16 |
|
|
|
|
| S | |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| NUMBER OF |
|
| BALLAST | |||||
|
|
|
| CELLS |
|
| COVER | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| CEILING |
|
|
|
| LOUVER FINISH*: |
|
| ||||
| TYPE: |
| L= | |||||||||
| S=Surface |
| P= | (standard) |
|
| ||||||
|
|
|
|
|
| |||||||
|
|
|
|
|
W= White Paint
2
LAMP |
| VOLTAGE: |
| OPTIONS: | ||
QUANTITY: |
| 120 or 277 |
| Add appropriate suffix | ||
(By Others) |
|
|
| to catalog no., ie: (GLR) | ||
2=2 Lamp |
| BALLAST TYPE: |
| |||
|
|
| ||||
|
| LE |
| |||
|
|
|
| <20THD | <10THD | |
LAMP/ | SO* | HI* | ||||
FIXTURE LENGTH: | LOL Dimming T8 | PS | – | |||
2U=T8, | ||||||
*Instant Start Standard |
|
| ||||
6U=6" U Lamp T8 or |
|
| ||||
T12 | Other dimming options. Consult factory. | |||||
(Nominal 24") |
|
|
|
|
OPTIONS & ACCESSORIES
STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.
(Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")
FUSING: Internal
SUFFIX: GLR.
Internal
SUFFIX: GMF.
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.
ELECTRICAL/WIRING OPTIONS Consult factory.
SPECIFICATIONS
PERFORMANCE: In an installation of 2U lamp 31W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .58. To prevent glare the VCP shall be not less than 87 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 914 footlamberts. To control veiling reflections, luminaire output in the
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are
LOUVER: pre-anodized aluminum (Coilzak® or equal).
STANDARD FINISH:
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902