CXS SERIES 2x2

CLEANGUARD CLASS 10,000 CLEAN ROOM

RECESSED FLUORESCENT

PHOTOMETRY MODEL NO. CXS2GFSVI26U120SO

CXS2GFSVI26U120SO

 

 

LER = FL - 56.0

IW - 53.7

BF - 0.87

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.24

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

ratio

1

69

66

63

62

60

58

59

58

56

3

57

51

46

48

44

41

46

43

40

 

2

63

58

54

54

51

48

52

50

47

cavity

4

53

45

40

43

38

35

41

38

34

5

48

41

35

38

34

30

37

33

30

room

6

45

37

31

35

30

27

34

30

26

8

39

30

25

29

24

21

28

24

21

 

7

42

33

28

32

27

24

31

27

23

 

9

36

28

23

27

22

19

26

22

19

 

10

34

26

21

25

20

17

24

20

17

ORDERING INFORMATION

Explanation of Catalog Number. Example: CXS2GFSVI26U120SOGLR

CX

S

2

 

 

 

 

 

VI

CLEANGUARD

WET

LOCATION

Class 10,000

or

100,000

Clean Room

STATIC

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXTURE

 

 

LENS FRAME:

 

 

LAMP

WIDTH

 

 

FS= Flat steel frame

 

QUANTITY:

 

 

 

 

 

RA=Regressed

 

 

 

2=2 Lamp

 

 

 

 

 

aluminum frame

 

 

3=3 Lamp

 

 

 

 

 

FA=Flat aluminum

 

 

 

 

 

 

 

 

 

 

frame

 

 

 

 

LAMP/

 

 

 

 

 

 

 

 

LENS/SHIELDING TYPE:

 

FIXTURE LENGTH:

 

 

 

 

 

 

 

 

VI=(virgin acrylic) .125

 

 

2U=T8, 1-5/8" U Lamp

 

 

 

 

CEILING TYPE:

 

 

 

 

 

 

 

 

 

standard. For options

 

 

17=T8, 2' Lamp

 

 

G= Grid (lay-in T bar)

 

 

 

 

 

 

 

 

 

 

consult factory.

 

 

6U=6" U Lamp (T8)

 

 

F=Flanged (overlap) Z spline

 

 

 

 

 

 

 

 

Smooth side of

 

 

FT=Twin Tube T5

 

 

 

and plaster frame

 

 

 

 

 

 

 

 

 

 

 

lens towards room.

 

 

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

Other dimming options. Consult factory.

 

 

 

 

 

 

VOLTAGE:

 

 

OPTIONS:

120 or 277

 

Add appropriate suffix

 

 

 

to catalog no., ie: (GLR)

 

 

 

 

 

BALLAST TYPE:

 

 

 

 

 

<20THD <10THD

1-1

& 1-2 Lamp Elec. T8

SO*

HI*

1-3

Lamp Elec. T8

O3*

H3*

1-1

& 1-2 Lamp Elec. TT5 SB*

IB*

(40 Watt)

 

I3*

1-3

Lamp Elec. TT5

X3*

LOL T8 Dimming

PS*

-

LOL TT5 Dimming

PB*

-

*Instant Start Standard

OPTIONS/ACCESSORIES

PLASTER FRAME: Catalog Number PF24.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number:

S2FCTRIM (each joint).

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

SPECIFICATIONS:

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling.

FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENSES: VI (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .125" nominal thickness (similar to pattern 12).

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc Listed.

We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

 

TECHNICAL INFORMATION • (978) 657-7600

 

 

631 AIRPORT ROAD, FALL RIVER, MA 02720 • (508) 679-8131

 

C.F.I. DIVISION OF CANLYTE, INC.

 

 

525 EDUCATION ROAD, CORNWALL, ONTARIO

 

A Genlyte Thomas Company

 

CANADA K6H 6C7 • (613) 938-6221

PRINTED IN USA 3/02