Photometry

ITL34139

LIGHTOLIER

PLA2G16LS26U120SO

2' x 2' Recessed Fluorescent, 3-1/8" Deep, 16 Cell Parabolic Louver Static and Air Return 2 Lamp, T8 or T12

 

 

LER = FP - 49.5

IW - 58.0 BF - 0.87

 

 

 

 

 

 

 

 

Model No. PLA2G16LS26U120SO

 

Comparative yearly lighting energy cost per 1000 lumens = $4.85

 

 

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

 

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

 

30

 

50

30

 

10

 

50

 

30

10

 

 

 

1

 

66

64

 

62

 

60

59

 

58

 

58

 

57

56

 

 

ratio

2

 

62

58

 

55

 

55

52

 

50

 

53

 

51

49

 

 

3

 

57

52

 

48

 

50

46

 

44

 

48

 

45

43

 

 

 

 

 

 

 

 

 

 

 

cavity

4

 

53

47

 

42

 

45

41

 

38

 

43

 

40

38

 

 

5

 

48

42

 

37

 

40

36

 

33

 

39

 

35

33

 

 

room

6

 

45

37

 

33

 

36

32

 

29

 

35

 

31

29

 

 

7

 

41

34

 

29

 

32

28

 

25

 

31

 

28

25

 

 

 

8

 

38

30

 

25

 

29

25

 

22

 

28

 

24

21

 

 

 

9

 

34

27

 

22

 

26

22

 

19

 

25

 

21

18

 

 

 

10

 

32

24

 

20

 

23

19

 

16

 

23

 

19

16

 

 

visual comfort probability (rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

 

20

 

 

20

 

 

81

75

71

80

 

 

 

79

69

60

 

71

 

20

 

 

30

 

 

84

78

74

73

 

 

 

82

73

66

 

65

 

20

 

 

40

 

 

86

80

77

75

 

 

 

82

75

70

 

69

 

 

20

 

 

60

 

 

87

81

80

78

 

 

 

83

75

73

 

72

 

30

 

 

20

 

 

85

79

71

76

 

 

 

83

75

64

 

70

 

30

 

 

30

 

 

87

82

74

70

 

 

 

86

78

68

 

65

 

30

 

 

40

 

 

88

83

77

72

 

 

 

86

79

72

 

68

 

 

 

 

 

 

 

 

 

 

30

 

 

60

 

lengthwise

89

84

80

75

 

 

crosswise

86

79

75

 

72

 

 

30

 

 

80

 

89

85

81

78

 

 

86

79

74

 

72

 

40

 

 

20

 

 

86

82

75

75

 

 

 

84

77

69

 

71

 

40

 

 

30

 

 

88

83

77

70

 

 

 

87

80

73

 

67

 

40

 

 

40

 

luminaries

89

85

80

73

 

 

luminaries

87

81

76

 

70

 

40

 

 

60

 

90

86

82

75

 

 

87

81

77

 

73

 

40

 

 

80

 

 

90

86

83

78

 

 

 

87

81

77

 

73

 

 

40

 

 

100

 

 

91

86

83

78

 

 

 

87

81

77

 

73

 

60

 

 

30

 

 

88

84

79

73

 

 

 

87

81

75

 

70

 

60

 

 

40

 

 

89

86

82

75

 

 

 

88

82

78

 

73

 

60

 

 

60

 

 

90

87

83

77

 

 

 

88

82

79

 

75

 

60

 

 

80

 

 

91

87

84

79

 

 

 

88

83

79

 

75

 

 

60

 

 

100

 

 

91

87

85

80

 

 

 

88

83

79

 

75

 

100

 

 

40

 

 

89

86

82

77

 

 

 

88

82

79

 

74

 

100

 

 

60

 

 

90

87

84

79

 

 

 

88

82

81

 

77

 

100

 

 

80

 

 

91

87

85

81

 

 

 

88

83

81

 

78

 

 

100

 

 

100

 

 

91

88

86

82

 

 

 

88

83

81

 

78

 

 

 

 

 

 

 

 

 

Ordering Information

Explanation of Catalog Number. Example: PLA2G16LS26U120SOGLR

PL

 

 

A

 

 

 

 

 

 

 

Paralyte

 

Body

Style:

2424:

 

A= Air Handling

3-1/8" Deep

 

/Static

Parabolic

 

 

 

 

 

 

 

 

Precision

 

 

 

 

Contoured Pre-

 

 

 

 

anodized

 

 

 

 

Aluminum

 

 

 

 

Louver

 

 

 

 

2

 

G

 

16

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixture

Ceiling Type:

Number of

 

 

 

Ballast Cover:

Width

G=Grid (lay-in T-bar)

Cells

 

 

 

S=Single V Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Finish:

L = Low

Iridescence

Semi-specular

(standard)

W = White Paint

2

Lamp

Quantity

6U

Lamp/

Fixture Length:

6" U Lamp T8 or T12 (Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

120 or 277

 

 

Add appropriate

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

no, ie: (GLR)

 

 

 

Ballast Type:

 

 

 

1–2 Lamp Mag. T12

LE*

<10THD

 

 

 

 

<20THD

1–2 Lamp Elec. T8

SO*

HI*

LOL T8 Dimming

PS*

*Instant Start Standard

Other dimming options. Consult factory.

Options & Accessories

Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),

Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: R. One per ballast. Suffix: B.

Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.

Specifications

Performance: In an installation of 2 lamp 31W Iuminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be less than 64. To prevent glare the VCP shall not be less than 88 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 206 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90° zone shall not be less than 68.6%.

Specifications (continued)

Air Return: Designed to provide optimum air return. Air is returned through the lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 2
Contents Mounting Methods FeaturesDimensions Job Information TypePhotometry Options & AccessoriesSpecifications Ordering Information