Lightolier C6T6W manual Frame-In Kit Lamp, Features, Electrical, Options and Accessories, Labels

Page 1

Calculite® HID Wall Wash C6T6W

Page 1 of 2

 

20" (508 mm) to

5

 

30" (762 mm)

 

 

9-3/4" (248 mm)

 

 

10-7/8" (276 mm)

 

 

11" (280 mm)

 

 

(150W)

 

 

Top View

 

 

(Electronic Ballast)

9-3/8"

 

20" (508 mm) to

(238 mm)

 

30" (762 mm)

 

 

9-3/4" (248 mm)

 

18-5/8" (473 mm)

10-1/2" (267 mm)

10-7/8" (276 mm)

Top View

(Magnetic Ballast)

Ceiling Cutout: 6 9/16" (167mm) Dia.

6" Aperture, T6 Ceramic Metal Halide

1

2

4

3

6

8

9

10

7

Fixture Support Membe 5/8" (16 mm) to

2 7/8" (73 mm)

5-3/4" (146 mm) Dia.

 

 

2" (50 mm) max.

 

7-7/8" (181 mm) Dia.

 

 

 

 

 

 

Ceiling Thickness

 

 

 

 

 

 

 

 

Reflector Trim

 

Frame-In Kit

Lamp

 

 

C6T6W CLW

Specular Clear, White Painted Flange.

C639T6E1

Electronic 120V

39W T6

Ceramic MH

 

CLP

Specular Clear, Matching Flange.

C639T6E2

Electronic 277V

39W T6

Ceramic MH

 

CCDW

Comfort Clear Diffuse, White Painted Flange.

C670T6E1

Electronic 120V

70W T6

Ceramic MH

 

CCDP

Comfort Clear Diffuse, Matching Flange.

C670T6E2

Electronic 277V

70W T6

Ceramic MH

 

CCZW

Champagne Bronze, White Painted Flange.

C615T6E1

Electronic 120V

150W T6

Ceramic MH

 

CCZP

Champagne Bronze, Matching Flange.

C615T6E2

Electronic 277V

150W T6

Ceramic MH

 

 

 

C615T6U

Magnetic 120V/277V

150W T6

Ceramic MH

 

 

 

 

 

 

 

 

Features

1.Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide beam optics ideal for general lighting and wall washing.

2.Downlight/Wall Washer Reflector: Provides vertical surface wall washing and downlighting. Low brightness with 50° visual cut off to lamp and lamp image.

3.Lamp Shield: High-temperature glass as required by code, captive during re-lamping. Light diffusion provides exceptionally smooth beam.

4.Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket. Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance.

5.Mounting Frame: 0.048" (18-ga.) galvanized steel. Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking fea- ture secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation.

6.Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.

7.Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attach- ment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.

8.Trim Retention Springs: Rust resistant springs secure reflector/housing for quick, tool-less installation.

9.Ballast / Socket Housing / Cover Assembly: Electronic, snaps onto junc- tion box without tools for inspection and ballast replacement, accessible from below.

10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.

11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical

Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating “A”, -5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating.

Electrical (Cont.)

*150W Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and pot- ted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.

Ballast

ANSI Code

Voltage

Max. Amps

Input Watts

39W MH

M130

120/277

0.39/0.17

44

70W MH

M139

120/277

0.67/0.29

78

150W

MH

M142

120/277

1.40/0.60

169/166

* 150W

MH

M142

120/277

3.70/1.60

180

Options and Accessories

Chicago Plenum: Consult Factory.

Labels

cULus (Suitable for Damp Locations), I.B.E.W.

For 150W, install fixtures with minimum spacing; 3 feet from center-to center of adjacent luminaries, 3” from top of luminaire to overhead building member; 1 1/2 feet from luminaire center to side building member.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

Lightolier a Genlyte companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Group LLC • B1204

Image 1
Contents Options and Accessories FeaturesFrame-In Kit Lamp ElectricalMultiple Units Footcandles On Wall Distance From Ceiling in FeetFrom Wall 3 On Center From Wall 4 On Center