Lightolier C6T6VN specifications Candlepower Distribution, Angle Mean CP Lumens, Wall, Rcr

Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculite® HID Downlight  C6T6VN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6" Aperture, 2pc Vertical, T6 Narrow Beam

39W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 3400 LMS. AROMAT ELECTRONIC BALLAST, CL Finish

CANDLEPOWER DISTRIBUTION

1,000

2,000

3,000

4,000

** EFFICIENCY = 64.0% ** SC = 0.6

 

ANGLE

MEAN CP

LUMENS

LUMINANCE SUMMARY

 

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

0

3984

 

 

CD. / SQ. M.

 

 

 

 

 

 

 

 

 

 

 

 

5

3765

352

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

3218

 

45

 

16034

 

CEILING

 

 

 

80%

 

 

70%

 

50%

 

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

2533

716

55

 

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

 

50

10

0

 

 

20

1816

 

65

 

0

 

 

 

 

60°

25

1212

583

75

 

162

 

 

 

RCR

 

Zonal Cavity Method

- Effective

Floor Cavity

Reflectance

= 20%

 

30

795

 

85

 

0

 

 

0

.76

.76

.76

.76

.74

.74

.71

.71

 

.68

.68

.64

 

 

35

570

368

 

 

 

 

 

 

 

 

 

 

 

 

 

1

.73

.72

.71

.70

.71

.68

.68

.66

 

.66

.64

.61

 

 

40

407

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

.71

.68

.66

.65

.67

.64

.65

.63

 

.63

.61

.59

 

 

45

189

155

ZONAL LUMENS AND PERCENTAGES

 

3

.68

.65

.63

.61

.64

.60

.63

.59

 

.61

.58

.57

 

 

50

14

 

 

 

 

 

 

 

4

.66

.62

.59

.57

.61

.57

.60

.56

 

.59

.56

.54

 

 

55

2

4

ZONE LUMENS

% LAMP %LUMINAIRE

 

 

 

 

0-30

1650

48.53

75.77

 

5

.63

.59

.56

.54

.59

.54

.57

.53

 

.57

.53

.52

 

 

60

0

 

 

 

 

 

 

0-40

2017

59.35

92.67

 

6

.61

.57

.54

.52

.56

.51

.55

.51

 

.55

.51

.50

 

 

65

0

0

 

 

 

 

0-60

2176

64.02

99.96

 

7

.59

.54

.51

.49

.54

.49

.53

.49

 

.52

.48

.47

 

 

70

0

 

0-90

2177

64.05

100.00

 

 

 

 

 

 

8

.57

.52

.49

.47

.51

.46

.51

.46

 

.50

.46

.45

 

 

75

1

1

40-90

159

4.70

7.33

 

 

 

 

 

9

.54

.49

.46

.44

.49

.44

.48

.44

 

.48

.44

.43

 

 

80

0

 

60-90

0

.02

.04

 

 

 

 

 

90-180

0

.00

.00

 

10

.52

.47

.44

.42

.47

.42

.46

.42

 

.46

.42

.41

 

 

85

0

0

0-180

2177

64.05

100.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30°

90

0

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2336FR, DATE: OCT 24, 2003

COMPUTED BY LSI PROGRAM **TEST-LITE**

70W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 6600 LMS. AROMAT ELECTRONIC BALLAST, CL Finish

CANDLEPOWER DISTRIBUTION

 

 

 

 

 

ANGLE

MEAN CP

LUMENS

 

 

 

 

0

7054

 

 

 

5

6730

630

1,750

 

10

5887

 

 

15

4740

1334

 

 

20

3463

 

 

60°

25

2357

1129

 

 

30

1584

 

3,500

 

35

1148

737

 

40

812

 

 

 

45

377

310

 

 

50

33

 

 

 

55

7

11

5,250

 

60

4

 

 

65

2

2

 

 

70

0

 

 

 

75

0

0

 

 

80

0

 

7,000

 

85

0

0

30°

90

0

 

 

 

LUMINANCE SUMMARY

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

CD. / SQ. M.

 

 

 

 

 

 

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

31949

 

CEILING

 

 

80%

 

 

70%

 

50%

 

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

688

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

 

50

10

0

 

65

 

350

 

 

 

 

75

 

0

 

 

 

RCR

Zonal Cavity Method

- Effective

Floor Cavity

Reflectance

= 20%

85

 

0

 

 

0

.75

.75

.75

.75

.73

.73

.70

.70

 

.67

.67

.63

 

 

 

 

 

 

 

 

 

 

 

 

 

1

.72

.71

.69

.68

.70

.67

.67

.65

 

.64

.63

.60

 

 

 

 

 

 

 

2

.69

.67

.65

.63

.66

.63

.64

.61

 

.62

.60

.58

 

ZONAL LUMENS AND PERCENTAGES

 

3

.67

.64

.61

.59

.63

.59

.61

.58

 

.60

.57

.55

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.64

.61

.58

.56

.60

.56

.59

.55

 

.58

.54

.53

 

0-30

3093

46.88

74.48

 

5

.62

.58

.55

.53

.57

.52

.56

.52

 

.55

.52

.50

 

0-40

3830

58.04

92.22

 

6

.60

.55

.52

.50

.55

.50

.54

.50

 

.53

.49

.48

 

0-60

4151

62.91

99.95

 

7

.57

.53

.50

.48

.52

.47

.51

.47

 

.51

.47

.46

 

0-90

4153

62.94

100.00

 

8

.55

.50

.47

.45

.50

.45

.49

.45

 

.49

.45

.44

 

40-90

323

4.89

7.78

 

 

 

 

9

.53

.48

.45

.43

.47

.43

.47

.42

 

.46

.42

.41

 

60-90

2

.03

.05

 

 

 

90-180

0

.00

.00

 

10

.51

.46

.43

.40

.45

.40

.45

.40

 

.44

.40

.39

 

0-180

4153

62.94

100.00

 

 

 

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 62.9% **

CERTIFIED TEST REPORT NO. 2334FR, DATE: OCT 14, 2003

SC = 0.6

COMPUTED BY LSI PROGRAM **TEST-LITE**

150W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 14000 LMS. AROMAT ELECTRONIC BALLAST, CL Finish

CANDLEPOWER DISTRIBUTION

 

 

 

 

 

ANGLE

MEAN CP

LUMENS

 

 

 

 

0

13758

 

 

 

5

13134

1232

3,750

 

10

11593

 

 

15

9424

2655

 

 

20

7028

 

 

60°

25

4935

2359

 

 

30

3491

 

7,500

 

35

2551

1627

 

40

1766

 

 

 

45

816

671

 

 

50

70

 

 

 

55

12

22

11,250

 

60

4

 

 

65

7

5

 

 

 

 

70

3

 

 

 

75

1

2

 

 

80

0

 

15,000

 

85

0

0

30°

90

0

 

 

 

LUMINANCE SUMMARY

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

CD. / SQ. M.

 

 

 

 

 

 

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

69119

 

CEILING

 

 

80%

 

 

70%

 

50%

 

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

1223

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

 

50

10

0

 

65

 

1001

 

 

 

 

75

 

344

 

 

 

RCR

Zonal Cavity Method

- Effective

Floor Cavity

Reflectance

= 20%

85

 

0

 

 

0

.73

.73

.73

.73

.71

.71

.68

.68

 

.65

.65

.61

 

 

 

 

 

 

 

 

 

 

 

 

 

1

.70

.69

.67

.66

.68

.65

.65

.63

 

.63

.61

.59

 

 

 

 

 

 

 

2

.67

.65

.63

.61

.64

.61

.62

.59

 

.60

.58

.56

 

ZONAL LUMENS AND PERCENTAGES

 

3

.65

.62

.59

.57

.61

.57

.59

.56

 

.58

.55

.54

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.62

.59

.56

.54

.58

.54

.57

.53

 

.56

.53

.51

 

0-30

6246

44.62

72.86

 

5

.60

.56

.53

.51

.55

.51

.54

.50

 

.53

.50

.49

 

0-40

7873

56.24

91.83

 

6

.58

.53

.50

.48

.53

.48

.52

.48

 

.51

.47

.46

 

0-60

8566

61.19

99.92

 

7

.55

.51

.48

.46

.50

.45

.50

.45

 

.49

.45

.44

 

0-90

8573

61.24

100.00

 

8

.53

.48

.45

.43

.48

.43

.47

.43

 

.47

.43

.42

 

40-90

700

5.00

8.17

 

 

 

 

9

.51

.46

.43

.41

.46

.41

.45

.41

 

.45

.40

.40

 

60-90

6

.05

.08

 

 

 

90-180

0

.00

.00

 

10

.49

.44

.41

.39

.43

.39

.43

.38

 

.43

.38

.38

 

0-180

8573

61.24

100.00

 

 

 

 

LUMINAIRE INPUT WATTS = 167

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 61.2% **

CERTIFIED TEST REPORT NO. 2333FR, DATE: OCT 13, 2003

SC = 0.7

COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • B1204

Lightolier is a Philips group brand

Image 2
Contents Frame-In Kit Lamp FeaturesOptions and Accessories ElectricalWall Candlepower DistributionAngle Mean CP Lumens RCR