Q-Logic 9120 quick start Changing the IP Address and Default Gateway

Page 6

To perform the actual switch installation, the site implementation engineer must perform the following tasks, which are detailed in this section.

Step 1. Check the installation site to verify the installation of cabinet power feeds, rails, and grounding.

Step 2. Inspect the packaging and equipment for any shipping damage. Any shipping damage should be reported to the shipping company. Only unpack the the equipment if there is no shipping damage.

Step 3. Record the equipment serial numbers.

Step 4. Physically install the switch in the rack.

Step 5. Install InfiniBand (IB) or IB/Fiber Optic cables between the SilverStorm 9120 and network devices.

Step 6. Install intra-cabinet power and grounding cables for the switch.

Step 7. Power up the switch.

Step 8. Change the default system IP address (192.168.100.9) and gateway IP address (255.255.255.0) for the master spine.

Step 9. Add the equipment to the network.

Changing the IP Address and Default Gateway

Using the RS232 Serial Port

Step 1. Connect null-modem/crossover serial cables to the RS-232 port of the switch spine module. If using a terminal emulation device, the settings should be:

8 data bits

no parity bits

1 stop bit

56K baud

Use VT100 emulation.

4

Image 6
Contents Quick Start Guide Support.qlogic.com Pre-Installation Checklist SilverStorm Quick Start GuideRelease Notes Installation Tasks LeafChanging the IP Address and Default Gateway To change the switch default gateway IP address enter System prompts for a password. At the prompt enterTo to exit the CLI enter Set OOB LAN IP WindowInstalling Documentation from a CD Place the Documentation CD in the CD-ROM drivePage Declaration of Conformity Standards appliedPage Page D000010-002 Rev. a