Aquacal 155, 120 Control Irrigation and Storm Run Off, Maintain Proper Clearances Around Heater

Page 20

MAINTENANCE & OPERATION (continued)

Control Irrigation and Storm Run Off

Control Irrigation: In regions were wells are used for irrigation, water quality is sometimes poor, and water spray can damage heater components. Regardless of water quality, it is important that irrigation be directed away from the heat pump.

Prevent rain water runoff from pouring directly into the heater. The heater is designed to withstand normal rainfall, but solid streams of water from roof drip-lines may eventually damage heat pump components.

If the heat pump resides beneath a roof edge, to promote heat pump longevity, a rain leader (gutter), or rain shield, will be necessary.

Maintain Proper Clearances Around Heater

For maximum efficiency, proper air flow clearances around heater must be maintained.

It is important to keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating fully through the heater, and will result in inefficient operation or damage to the heat pump.

In addition, do not place objects on top of the heat pump; doing so will lock the air from exiting the heater, and will result in damage to the compressor and fan motor.

Proper clearances are also necessary in order to access the working parts of your heater. A heater that is easy to "get to," will be a heater that is easy to maintain; service and maintenance personnel will thank you for keeping the area around your heater unobstructed.

Please see diagrams, below, for specific clearance requirements.

OVERHANG

WITH GUTTER

RAIN RUN-OFF

MUST BE

DIRECTED AWAY

FROM UNIT.

30” MINIMUM CLEARANCE

5FT. MINIMUM

CLEARANCE

100 & 120 MODELS

1- FT.

155MODELS 2-FT. (REAR)

100& 120 MODELS 12-INCHES 155 MODELS 24-INCHES

(REAR)

 

 

24-

24-

 

 

INCHES

INCHES

 

 

(SIDE)

(SIDE)

 

 

 

 

 

 

 

 

 

30-INCHES

(FRONT)

SIDE VIEW (NO SCALE)

TOP VIEW (NO SCALE)

20

Image 20
Contents Installation Guide Page Table of Contents Maintenance and General Operation Eam Important Features of Your New Heat Pump HOW a Heat Pump Works Heat Pump Does Not Make Heat…Safety Information Safety SignalsWater Temperature Safety Water Chemistry SafetyVerify Electrical Power is Present at Heater HEATING- Quick Start & StopHEATING-QUICK Start & Stop To Begin HeatingProgram Filter Pump Run Time Continuous Usage and Water Around HeaterHeater Controls Control Panel LayoutHeater Controls Operational & Programming CodesStart Up & Setting Operating Controls Applying Power to The ControllerMode Controls Explained, and Starting the Heat Pump Owner-Level Programming Instructions CompleteStart Up & Setting Operating Controls Selecting Pool/Spa Thermostat SettingsChanging The Pool Temperature Set Point Changing The Spa Temperature Set PointUser Lock Code Option ULC Selecting Call-Flex Pump Options CFO Safety During Cleaning Operations Maintenance Operational RecommendationsGeneral Maintenance Control Water Chemistry Maintenance & OperationMaintain Proper Water Flow Control Irrigation and Storm Run Off Maintain Proper Clearances Around HeaterMaintenance & Operation Heating Tips Heating in Cooler WeatherPool/Spa Blankets Pool and Spa Combination HeatingCalculating Initial Heating Time At Start Up Continuous Circulator Pump Operation RequiredMaintenance & Operation Seasonal Use & Shut Down During the Swim SeasonFreeze Protection & Extended Shut Down Winterizing for Hard Freeze ConditionsWinterizing Procedure Planned Maintenance Program 20-Point Planned Maintenance Service Includes the FollowingTroubleshooting Heat Pump Fails to OperateHeat Pump Running... but is it Heating? Water Coming from the Heat PumpTroubleshooting Flowchart Heat Pump Fails to OperateProblem Solved Heat Pump Running... but is it Heating?Testing Water Coming from Heat PumpPage Specific Dealerinformation Follows DEALER-SPECIFIC Table of Contents Level-2 dealer-service Programming Data Plate Nomenclature 100 & 120 Models SpecificationsPhysical Characteristics Performance/Size/Weight Water/Electrical Requirements Heating Only Models120AHDE 120BHDE 120DHDT 120HHDT 155AHDE 155BHDE 155DHDT 155GHDE Installation Placement of HeaterIndoor Installation Outdoor InstallationAnchoring Heater to Pad Irrigation, Rainwater Runoff, and Landscape FeaturesEquipment Mounting Pad Requirements Plumbing Requirements Installation Plumbing RequirementsPlumbing Schematics-Flow 20 to 70-GPM Water in & OUT Connections- TypicalConnecting External Controllers Electrical RequirementsGeneral Requirements Code-Specific RequirementsWord Concerning Ground-Fault Protection Electrical RequirementsControls Configuration & Adjustments Entering Service MenuControls Configuration & Adjustments Time Delay dELConfiguring for External Controllers JAO or FS2 Water Sensor Calibration tSCDefrost Sensor Calibration dSC Checking-Adjusting Water Sensor CalibrationPool Dead Band Differential dBP Defrost Sensor CalibrationSpa Dead Band Differential dBS Changing the Service Lock Code and Back Door Entry Pool Dead Band DifferentialService Adjustable Parameters Level -1 and Level-2 Default SettingsTroubleshooting Using Displayed Codes Interpreting Error CodesRepositioning the Mode Jumper Mode Jumper ExplainedVerifying the Mode Jumper Position is Correct Controls Configuration & Adjustments Defrost Systems- Described Water Flow Pressure Switch Adjustment Locate Water Pressure Switch and Identify TypeTo Adjust a Len Gordon Switch To Adjust a TecMark SwitchLen Gordon Style Switch WPS Location TecMark Style Switch To Complete the Adjustment Procedure- Either Brand SwitchContacting the Factory Page 2737 24th St. North St. Petersburg, FL Heat Pump OWNER’S Instructions Getting Familiar with Controls Digital CONTROLLER- Operational Displays Getting Your Heat Pump Started & Stopped Continuous Usage and Water around Unit

120, 155 specifications

Aquacal 155,120 is a highly regarded pool heater known for its efficiency, reliability, and advanced technology. This product stands out in the competitive market of swimming pool heating solutions, making it a popular choice among pool owners and professionals alike.

One of the main features of the Aquacal 155,120 is its high-performance heat exchanger, made from durable titanium. This material ensures resistance to corrosion and enhances the longevity of the heater. The titanium heat exchanger is designed to facilitate maximum heat transfer, providing rapid warming of pool water and ensuring a consistent swimming experience.

The units are equipped with a powerful compressor that utilizes advanced inverter technology. This technology enables the heater to adjust its output according to the pool’s needs, optimizing energy consumption and reducing operational costs. The inverter-driven compressor allows the Aquacal 155,120 to operate quietly, making it ideal for residential settings where noise could be a concern.

Aquacal has designed the unit to be user-friendly, featuring an intuitive digital control panel. This control panel allows users to easily monitor and adjust the temperature settings, ensuring that the water temperature can be maintained at a comfortable level. Additionally, this feature includes programmable settings to enable automatic heating schedules, providing convenience and energy savings for pool owners.

The Aquacal 155,120 is also known for its energy efficiency. With a high coefficient of performance (COP), this heater can deliver more heat output per unit of energy consumed compared to traditional heating systems. This efficiency contributes to a lower carbon footprint, making it an environmentally friendly choice for heating pool water.

Furthermore, the unit is designed with robust insulation, which minimizes heat loss and maximizes energy retention. This insulation helps maintain the desired water temperature for longer periods, reducing the need for frequent reheating and thereby lowering energy expenses.

In summary, the Aquacal 155,120 is an outstanding choice for pool owners looking for an efficient, reliable, and technologically advanced heating solution. With its titanium heat exchanger, inverter technology, user-friendly control panel, energy efficiency, and excellent insulation, this pool heater stands out as a top contender for modern pool heating needs. Whether for leisure activities or extended swimming seasons, the Aquacal 155,120 ensures a comfortable and enjoyable swimming experience.