CAUTION - Inspection
Inspection and other services should always be carried out on hard and level ground with the engine shut down.
Inspection and Maintenance ServiceTables.
1.To make sure your plate compactor is always in good working condition before using, carry out the maintenance inspection in accordance with Tables 5 through 7.
TABLE 5. MVH-64H MACHINE INSPECTION
ITEM | HOURS OF | REMARKS | |
OPERATION | |||
|
| ||
|
|
| |
Damaged Parts | Every 8 hours |
| |
(every day) |
| ||
|
| ||
|
|
| |
Loose or Lost Screws | Every 8 hours |
| |
(every day) |
| ||
|
|
| |
Function of Controlling | Every 8 hours |
| |
System Part | (every day) |
| |
|
|
| |
Vibrator Oil Check | Every 100 hours | See page 16 | |
|
|
| |
Vibrator Oil | Every 300 hours | See page 21 | |
Replacement | |||
|
| ||
|
|
| |
Every 200 hours | See pages 17 and 21 | ||
|
|
|
TABLE 6. ENGINE CHECK
(For details, see separate Engine Manual)
Item | Hours of Operation | |
|
| |
Leakage of oil or fuel | Every 8 hours (every day) | |
|
| |
Tightness of fastening threads | Every 8 hours (every day) | |
|
| |
| Every 8 hours (every | |
Engine oil check and replenishment | day)(Replenish to specified max. | |
| level) | |
|
| |
Engine oil replenishment | At first 20 hours, then every 100 | |
hours | ||
| ||
|
| |
Air cleaner cleaning | Every 50 hours | |
|
|
MVC-64H/HW — MAINTENANCE
CAUTION - Inspection Intervals
These inspection intervals are for operation under normal conditions. Adjust your inspection intervals based on the number of hours plate compactor is in use, and particular working conditions.
CAUTION - Inspection Intervals
Fuel piping and connections should be replaced every 2 years.
Daily Service
zCheck for leakage of fuel or oil.
zRemove soil and clean the bottom of compaction plate.
zCheck engine oil, see page 16.
zCheck for loose screws including tightness. See Table 7 below (tightening torque ), for retightening:
TABLE 7.
TIGHTENING TORQUE (in. kg/cm) Diameter
Material | 6mm | 8mm | 10mm | 12mm | 14mm | 16mm | 18mm | 20mm |
|
|
|
|
|
|
|
|
|
4T | 70 | 150 | 300 | 500 | 750 | 1,100 | 1,400 | 2,000 |
|
|
|
|
|
|
|
|
|
100 | 250 | 500 | 800 | 1,300 | 2,000 | 2,700 | 3,800 | |
|
|
|
|
|
|
|
|
|
11T | 150 | 400 | 800 | 1,200 | 2,000 | 2,900 | 4,200 | 5,600 |
|
|
|
|
|
|
|
|
|
*100 (6mm) 300 ~ 350 (8mm) 650 ~ 700 (10mm)
*(In case
(Threads in use with this machine are all right handed)
Material and quality of material is marked on each bolt, and screw.
Engine Oil Replacement:
1.Replace engine oil, in first 20 hours of operation and every 100 hours afterwards.
2.Oil may be drained more easily when it is warm after operation (For more details, see separate HONDA Owner's Manual).
3.When changing the engine oil, the old oil can be drained by removing the oil filler cap, and unscrewing the engine oil drain plug located at the base of the engine (Figure 16).
4.Remember to refill engine crankcase with the recommended type of oil as listed in Table 4.
PAGE 20 —