General Operating Procedures
1.Make sure the Power Switch (3) is in its “0” (OFF) position. Then plug the Pow- er Cord (1) of the tool into the nearest 120 volt, grounded, electrical outlet.
(See Figure A, previous page.)
2.To turn on the Heat Gun, set its Power Switch (3) to “l” or “ll”.(See Figure A.)
•Switch “l” - Low temperature position (572° Fahrenheit maximum). Used for mild heating applications, i.e., heat shrink tube, heat shrink bag, plastic bending, shaping and welding, removing old paint coating. (See Figure A.)
•Switch “ll” - High temperature position (1076° Fahrenheit maximum). Used for intense heating applications, i.e., frozen water pipe, defrosting refrigerator, and metal welding. (See Figure A.)
3.To turn off the Heat Gun, set its Power Switch (3) to “l”. Then set the Power Switch to “0” and unplug the tool from its electrical outlet. (This method helps cool down the Heat Element (11) properly to extend the life of the Heat Gun.)
(See Figure A.)
4.CAUTION! Danger of fire. Make sure to set the Heat Gun on a
5.Once cooled, store the Heat Gun in a clean, dry, safe location out of reach of children and other unauthorized people.
|
| |
| Maintenance And Servicing | |
| Risk of serious personal injury from accidental starting | |
WARNING | ||
or electric shock. Turn the Power Switch of the tool to its | ||
| ||
| “OFF” position and unplug the tool from its electrical outlet | |
| and allow the tool to completely cool before performing any | |
| inspection, maintenance, or cleaning procedures. |
Damaged equipment can fail, causing serious personal injury. Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Inspection, Maintenance, and Cleaning
1.DISCONNECT from power outlet and make sure that it is completely cooled.
2.BEFORE EACH USE, inspect the general condition of the Heat Gun. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, and any other condition that may affect its safe operation.