DETAILED COOLING CAPACITIES* continued

 

EVAPORATOR

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

75

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

MBtuh†

MBtuh†

 

MBtuh†

MBtuh†

MBtuh†

MBtuh†

 

 

 

System

System

System

System

System

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

EWB

Total

Sens‡

KW**

Total

Sens‡

KW**

 

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

698BNX024000 Outdoor Section With FV4ANF002 Indoor Section - Low Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

15.50

8.28

0.76

14.45

7.88

0.87

 

13.34

7.47

0.96

12.16

7.03

1.05

10.93

6.59

1.12

9.65

6.14

1.18

 

400

67

13.90

10.19

0.78

12.89

9.77

0.87

 

11.82

9.33

0.96

10.69

8.87

1.03

9.53

8.40

1.09

8.36

7.94

1.14

 

63††

12.74

9.76

0.79

11.76

9.32

0.88

 

10.71

8.86

0.95

9.64

8.39

1.01

8.54

7.92

1.07

7.45

7.44

1.11

 

 

62

12.45

12.10

0.79

11.56

11.54

0.87

 

10.75

10.75

0.95

9.92

9.92

1.02

9.07

9.07

1.08

8.19

8.19

1.14

 

 

57

12.30

12.30

0.79

11.55

11.55

0.87

 

10.75

10.75

0.95

9.92

9.92

1.02

9.07

9.07

1.08

8.19

8.19

1.14

 

 

72

16.11

9.11

0.75

15.01

8.70

0.87

 

13.83

8.28

0.97

12.58

7.84

1.05

11.30

7.38

1.13

9.95

6.93

1.20

 

500

67

14.47

11.51

0.77

13.40

11.07

0.88

 

12.27

10.61

0.96

11.09

10.14

1.04

9.88

9.65

1.11

8.83

8.83

1.17

 

63††

13.28

11.00

0.79

12.24

10.54

0.88

 

11.14

10.07

0.96

10.02

9.59

1.03

8.95

8.95

1.08

8.00

8.00

1.14

 

 

62

13.33

13.33

0.79

12.51

12.51

0.88

 

11.65

11.65

0.96

10.74

10.74

1.04

9.80

9.80

1.10

8.83

8.83

1.17

 

 

57

13.33

13.33

0.79

12.51

12.51

0.88

 

11.65

11.65

0.96

10.73

10.73

1.04

9.80

9.80

1.10

8.83

8.83

1.17

 

 

72

16.50

9.87

0.75

15.35

9.46

0.87

 

14.14

9.04

0.97

12.86

8.60

1.06

11.53

8.15

1.14

10.15

7.67

1.21

 

600

67

14.85

12.74

0.77

13.75

12.28

0.88

 

12.58

11.82

0.97

11.40

11.30

1.05

10.36

10.36

1.12

9.31

9.31

1.19

 

63††

13.65

12.17

0.79

12.58

11.68

0.89

 

11.46

11.19

0.97

10.42

10.42

1.04

9.44

9.44

1.10

8.43

8.43

1.16

 

 

62

14.32

13.73

0.78

13.25

13.25

0.88

 

12.32

12.32

0.97

11.36

11.36

1.05

10.36

10.36

1.12

9.34

9.34

1.19

 

 

57

14.12

14.12

0.78

13.25

13.25

0.88

 

12.33

12.33

0.97

11.36

11.36

1.05

10.36

10.36

1.12

9.31

9.31

1.19

 

 

72

16.76

10.58

0.75

15.60

10.18

0.87

 

14.36

9.76

0.98

13.06

9.32

1.07

11.69

8.86

1.15

10.27

8.39

1.22

 

700

67

15.13

13.87

0.77

14.02

13.41

0.88

 

12.91

12.79

0.98

11.86

11.86

1.06

10.80

10.80

1.14

9.70

9.70

1.20

 

63††

13.92

13.25

0.79

12.86

12.70

0.89

 

11.86

11.86

0.97

10.86

10.86

1.05

9.83

9.83

1.12

8.76

8.76

1.18

 

 

62

14.74

14.74

0.78

13.83

13.83

0.88

 

12.87

12.87

0.98

11.86

11.86

1.06

10.80

10.80

1.14

9.70

9.70

1.20

 

 

57

14.74

14.74

0.78

13.83

13.83

0.88

 

12.87

12.87

0.98

11.86

11.86

1.06

10.80

10.80

1.14

9.70

9.70

1.20

 

 

72

16.94

11.23

0.75

15.77

10.85

0.87

 

14.52

10.46

0.98

13.20

10.02

1.08

11.80

9.56

1.16

10.36

9.07

1.23

 

800

67

15.37

14.93

0.77

14.30

14.30

0.89

 

13.30

13.30

0.98

12.24

12.24

1.07

11.15

11.15

1.15

10.00

10.00

1.22

 

63††

14.19

14.12

0.79

13.23

13.23

0.89

 

12.24

12.24

0.98

11.20

11.20

1.06

10.14

10.14

1.13

9.02

9.02

1.19

 

 

62

15.27

15.27

0.78

14.30

14.30

0.89

 

13.30

13.30

0.98

12.25

12.25

1.07

11.15

11.15

1.15

10.01

10.01

1.22

 

 

57

15.24

15.24

0.78

14.30

14.30

0.89

 

13.31

13.31

0.98

12.25

12.25

1.07

11.15

11.15

1.15

10.01

10.01

1.22

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

 

Low Speed

 

Indoor

 

Low Speed

 

 

 

 

 

 

 

Section

Size

Capacity

Power

Section

Size

Capacity

Power

 

 

 

 

 

 

 

 

 

CC5A/CD5AA

024

1.02

 

1.17

FV4ANF

002

1.00

1.00

 

030

1.02

 

1.17

 

003

1.00

1.00

 

036

1.04

 

1.16

COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE

CC5A/CD5AB

024

1.02

 

1.17

CC5A/CD5AA

024

1.02

1.06

 

030

1.02

 

1.17

 

030

1.02

1.04

 

036

1.04

 

1.16

 

036

1.02

1.01

CC5A/CD5AW

024

1.02

 

1.17

CC5A/CD5AB

024

1.02

1.06

 

030

1.02

 

1.17

 

030

1.02

1.04

 

036

1.04

 

1.16

 

036

1.02

1.01

CE3AA

024

1.02

 

1.17

CC5A/CD5AW

024

1.02

1.04

 

030

1.04

 

1.17

 

030

1.02

1.04

 

036

1.02

 

1.15

 

036

1.02

1.01

CF5AA

024

1.02

 

1.16

CE3AA

024

1.02

1.04

 

036

1.04

 

1.16

 

030

1.02

1.02

CK3BA

024

1.04

 

1.16

 

036

1.02

1.02

 

030

1.04

 

1.16

CK3BA

024

1.02

1.01

 

036

1.02

 

1.13

 

030

1.02

1.01

CK5A/CK5BA

024

1.04

 

1.16

 

036

1.04

1.00

 

030

1.04

 

1.16

CK5A/CK5BA

024

1.04

1.01

 

036

1.02

 

1.13

 

030

1.04

1.01

CK5A/CK5BN

036

1.02

 

1.13

 

036

1.04

1.00

CK5A/CK5BT

036

1.02

 

1.13

CK5A/CK5BN

036

1.04

1.01

CK5A/CK5BW

024

1.04

 

1.16

CK5A/CK5BT

036

1.04

1.00

 

030

1.04

 

1.16

CK5A/CK5BW

024

1.04

1.01

 

036

1.02

 

1.13

 

030

1.04

1.00

FK4CNF

001

1.00

 

1.01

 

 

002

1.00

 

1.00

 

 

 

 

 

003

1.00

 

1.00

 

 

 

 

See notes on page 27.

—14—

Image 14
Contents 698B 60 HZ Unit Sound DimensionsUnit Minimum Mounting Size Octave Band Center Frequency HzDiameter In.OD Recommended Tube DiametersUnit Tube Length Liquid Tube Vapor Tube Specifications 024-A 036-A 048-A 060-ASupport Feet Coastal FilterSnow Stand Combination Ratings Coils + 333B,JAV048080 Variable Speed Furnace HeatingCooling‡ High-Temp Low-Temp Coils + 333B,JAV060100 Variable Speed FurnaceCoils + 355MAV042060 Variable Speed Furnace Seer EERCoils + 355MAV042040 Variable Speed Furnace Coils + 355MAV042080 Variable Speed Furnace1470 1400 1838 1138 698BNX Balance Point Worksheet A01067Indoor High Speed Size Capacity PowerDetailed Cooling Capacities Size CapacityIndoor Indoor Low SpeedSize CD5AB20.42 Coils + 355MAV060100 Variable Speed Furnace Coils +333B,JAV036060 Variable Speed Furnace Coils +333B,JAV048080 Variable Speed FurnaceCoils +333B,JAV060120 Variable Speed Furnace Coils +333B,JAV060100 Variable Speed Furnace11.99 Coils + 355MAV060100 Variable Speed Furnace Section Size Capacity Power Coils + 355MAV060120 Variable Speed Furnace 30.89 Size Capacity Power 71.35 39.02 EDB CFM Indoor Outdoor Coil Entering AIR Temperatures FHeat Pump Heating Performance KW†Indoor Cooling Section Total CapacityTotal Capacity MBtuh† Size Capacity Power Section Capacity Total MBtuh†048 See notes on Capacity Power Indoor Cooling Section Size Capacity Section Size CapacityCoils + 355MAV042060 Variable Speed Furnace Coils + 355MAV060100 Variable Speed Furnace 060 See notes on Capacity Power 20.48 Capacity Total Capacity Total MBtuh† Pwr System Design Page
Related manuals
Manual 16 pages 12.64 Kb

698B specifications

The Bryant 698B is an advanced residential air conditioning unit known for its efficiency and reliability in delivering optimal indoor climate control. Designed for comfort and energy savings, the Bryant 698B is a notable choice for homeowners seeking high-performance cooling solutions.

One of its standout features is its impressive Seasonal Energy Efficiency Ratio (SEER) rating, which ranges from 16 to 18, depending on the specific model. This high efficiency helps to reduce energy consumption while providing consistent cooling performance, allowing homeowners to enjoy a comfortable environment without incurring high electricity bills. The unit's efficient operation is recognized by various energy efficiency certifications, helping promote a more sustainable lifestyle.

The Bryant 698B is equipped with a variable-speed compressor, which adjusts its operating speed based on the cooling needs of the home. This technology allows the system to run at lower speeds for longer periods, ensuring a more consistent temperature throughout the space and reducing wear and tear on the system. This also minimizes noise levels, making the Bryant 698B one of the quieter units available today.

In terms of build quality, the Bryant 698B features a durable steel cabinet designed to withstand harsh weather conditions. The unit is treated with a baked-on powder finish that provides corrosion resistance, ensuring its longevity even in challenging environments. Additionally, the coil is designed for easy maintenance, allowing for optimal airflow and ensuring the system runs efficiently.

Smart technology integration is another highlight of the Bryant 698B. The unit can be connected to a smart thermostat, offering homeowners remote access to control their HVAC system from their smartphones. This capability allows for more precise temperature adjustments and scheduling, contributing to enhanced energy savings and increased comfort.

The Bryant 698B also offers various customizable options, including different cooling capacities and compatibility with additional heating systems like heat pumps or gas furnaces. This versatility makes it suitable for a wide range of residential applications.

In summary, the Bryant 698B air conditioning unit stands out due to its energy efficiency, variable-speed compressor, durable construction, smart technology features, and customization options, making it an ideal choice for homeowners looking for a robust and efficient cooling solution.