Bryant 698B warranty 39.02

Page 27

DETAILED COOLING CAPACITIES* continued

 

EVAPORATOR

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

75

 

 

85

 

 

95

 

 

105

 

 

 

115

 

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

Capacity

Total

Capacity

 

Total

 

 

 

MBtuh†

MBtuh†

MBtuh†

MBtuh†

 

MBtuh†

MBtuh†

 

 

 

 

System

System

System

System

 

System

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

EWB

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

 

Total

Sens‡

KW**

Total

Sens‡

 

KW**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

698BNX060000 Outdoor Section With FV4ANB006 Indoor Section - Low Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

39.02

21.16

1.92

35.81

19.95

2.10

32.58

18.77

2.28

29.35

17.61

2.45

 

26.10

16.45

2.61

22.77

15.30

 

2.77

 

1050

67

34.93

26.32

1.91

32.03

25.08

2.08

29.04

23.90

2.24

26.12

22.73

2.40

 

23.23

21.56

2.55

20.35

20.34

 

2.70

 

63††

32.03

25.19

1.89

29.24

23.94

2.06

26.54

22.74

2.21

23.84

21.60

2.36

 

21.21

20.45

2.51

18.76

18.76

 

2.65

 

 

62

31.45

31.29

1.89

29.23

29.23

2.06

27.08

27.08

2.22

24.92

24.92

2.38

 

22.70

22.70

2.55

20.35

20.35

 

2.70

 

 

57

31.37

31.37

1.89

29.22

29.22

2.06

27.08

27.08

2.22

24.90

24.90

2.38

 

22.68

22.68

2.54

20.35

20.35

 

2.70

 

 

72

40.53

23.56

1.96

37.05

22.31

2.15

33.59

21.09

2.33

30.15

19.89

2.50

 

26.70

18.70

2.67

23.18

17.51

 

2.83

 

1350

67

36.34

30.17

1.95

33.19

28.82

2.13

30.00

27.61

2.29

26.96

26.33

2.46

 

24.39

24.18

2.63

21.59

21.59

 

2.78

 

63††

33.31

28.78

1.93

30.37

27.48

2.11

27.47

26.22

2.27

24.93

24.38

2.42

 

22.36

22.36

2.57

19.90

19.90

 

2.73

 

 

62

34.08

34.08

1.94

31.67

31.67

2.12

29.22

29.22

2.29

26.76

26.76

2.45

 

24.25

24.25

2.62

21.59

21.59

 

2.78

 

 

57

34.08

34.08

1.94

31.67

31.67

2.12

29.21

29.21

2.29

26.77

26.77

2.45

 

24.24

24.24

2.62

21.59

21.59

 

2.78

 

 

72

41.45

25.78

2.00

37.81

24.50

2.19

34.19

23.26

2.37

30.61

22.03

2.55

 

27.03

20.82

2.71

23.37

19.59

 

2.88

 

1650

67

37.24

33.68

1.99

33.94

32.30

2.17

30.79

30.74

2.34

28.11

28.10

2.51

 

25.34

25.34

2.68

22.45

22.45

 

2.85

 

63††

34.20

32.09

1.98

31.16

30.62

2.15

28.47

28.47

2.32

25.94

25.94

2.48

 

23.58

23.04

2.65

20.68

20.68

 

2.80

 

 

62

36.09

36.09

1.98

33.43

33.43

2.17

30.88

30.85

2.35

28.08

28.08

2.51

 

25.34

25.34

2.68

22.45

22.45

 

2.85

 

 

57

36.09

36.09

1.98

33.43

33.43

2.17

30.77

30.77

2.34

28.03

28.03

2.51

 

25.33

25.33

2.68

22.44

22.44

 

2.85

 

 

72

42.05

27.84

2.03

38.30

26.53

2.23

34.58

25.28

2.42

30.90

24.03

2.59

 

27.20

22.77

2.76

23.48

21.47

 

2.92

 

1950

67

37.94

36.85

2.03

34.80

34.72

2.22

31.94

31.94

2.39

29.06

29.06

2.57

 

26.12

26.12

2.74

23.05

23.05

 

2.91

 

63††

34.96

34.82

2.02

32.20

32.20

2.20

29.49

29.49

2.37

26.80

26.80

2.53

 

24.05

24.05

2.69

21.21

21.21

 

2.85

 

 

62

37.60

37.60

2.03

34.77

34.77

2.21

31.94

31.94

2.39

29.06

29.06

2.57

 

26.12

26.12

2.74

23.05

23.05

 

2.91

 

 

57

37.60

37.60

2.03

34.77

34.77

2.21

31.94

31.94

2.39

29.06

29.06

2.57

 

26.12

26.12

2.74

23.05

23.05

 

2.91

 

 

72

42.47

29.81

2.07

38.62

28.50

2.27

34.83

27.22

2.46

31.06

25.93

2.63

 

27.32

24.61

2.80

23.58

23.13

 

2.96

 

2250

67

38.80

38.80

2.07

35.82

35.82

2.26

32.82

32.82

2.44

29.80

29.80

2.62

 

26.71

26.71

2.79

23.47

23.47

 

2.96

 

63††

36.00

35.99

2.06

33.12

33.12

2.24

30.28

30.28

2.41

27.47

27.46

2.58

 

24.57

24.57

2.74

21.60

21.60

 

2.91

 

 

62

38.80

38.80

2.07

35.82

35.82

2.26

32.82

32.82

2.44

29.80

29.80

2.62

 

26.72

26.72

2.79

23.48

23.48

 

2.96

 

 

57

38.81

38.81

2.07

35.82

35.82

2.26

32.82

32.82

2.44

29.81

29.80

2.62

 

26.71

26.71

2.79

23.48

23.48

 

2.96

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

Low Speed

Indoor

 

Low Speed

 

 

 

 

 

 

 

 

Section

Size

Capacity

Power

Section

Size

Capacity

Power

 

 

 

 

 

 

 

 

 

 

CC5A/CD5AA

060

0.93

1.14

CK3BA

060

0.97

1.02

 

CC5A/CD5AB

060

0.93

1.14

CK5A/CK5BA

060

0.97

1.01

 

CC5A/CD5AW

060

0.95

1.14

CK5A/CK5BN

060

0.99

1.02

 

CE3AA

060

0.95

1.14

CK5A/CK5BT

060

0.97

1.01

 

CK3BA

060

0.95

1.14

CK5A/CK5BX

060

0.99

1.02

 

CK5A/CK5BA

060

0.95

1.14

COILS + 355MAV060100 VARIABLE SPEED FURNACE

 

CK5A/CK5BN

060

0.96

1.14

CC5A/CD5AA

060

0.95

1.04

 

CK5A/CK5BT

060

0.95

1.14

CC5A/CD5AB

060

0.95

1.04

 

CK5A/CK5BX

060

0.96

1.14

CC5A/CD5AW

060

0.97

1.03

 

FK4CNB

006

0.99

0.99

CE3AA

060

0.98

1.04

 

FV4ANB

006

1.00

1.00

CK3BA

060

0.97

1.04

 

COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE

CK5A/CK5BA

060

0.97

1.04

 

CC5A/CD5AA

060

0.95

1.01

CK5A/CK5BN

060

0.99

1.05

 

CC5A/CD5AB

060

0.95

1.01

CK5A/CK5BT

060

0.97

1.04

 

CC5A/CD5AW

060

0.97

1.01

CK5A/CK5BX

060

0.99

1.04

 

CE3AA

060

0.98

1.01

COILS + 355MAV060120 VARIABLE SPEED FURNACE

 

CK3BA

060

0.97

1.01

CC5A/CD5AA

060

0.97

1.04

 

CK5A/CK5BA

060

0.97

1.01

CC5A/CD5AB

060

0.97

1.04

 

CK5A/CK5BN

060

0.98

1.01

CC5A/CD5AW

060

0.97

1.04

 

CK5A/CK5BT

060

0.97

1.01

CE3AA

060

0.98

1.04

 

CK5A/CK5BX

060

0.98

1.01

CK3BA

060

0.97

1.04

 

COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE

CK5A/CK5BA

060

0.97

1.04

 

CC5A/CD5AA

060

0.97

1.02

CK5A/CK5BN

060

0.99

1.05

 

CC5A/CD5AB

060

0.97

1.02

CK5A/CK5BT

060

0.97

1.04

 

CC5A/CD5AW

060

0.97

1.01

CK5A/CK5BX

060

0.99

1.04

 

CE3AA

060

0.98

1.02

 

* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C). When the required data falls between the published data, interpotlation may be performed.

** Unit kw is total of indoor and outdoor unit kilowatts.

††Sensible capacity multipliers are based on the rated airflow of the listed indoor section. Refer to the airflow listed in the “Combination Ratings” table. ‡‡ At TVA rating indoor condition (75°F edb/63°F EWB). All other indoor air temperatures are at 80°F EDB.

EWB—Entering Wet Bulb.

—27—

Image 27
Contents 698B 60 HZ Octave Band Center Frequency Hz DimensionsUnit Minimum Mounting Size Unit SoundRecommended Tube Diameters Unit Tube Length Liquid Tube Vapor TubeDiameter In.OD 024-A 036-A 048-A 060-A SpecificationsCoastal Filter Snow StandSupport Feet Combination Ratings Coils + 333B,JAV060100 Variable Speed Furnace HeatingCooling‡ High-Temp Low-Temp Coils + 333B,JAV048080 Variable Speed FurnaceCoils + 355MAV042080 Variable Speed Furnace Seer EERCoils + 355MAV042040 Variable Speed Furnace Coils + 355MAV042060 Variable Speed Furnace1470 1400 1838 1138 A01067 698BNX Balance Point WorksheetSize Capacity Size Capacity PowerDetailed Cooling Capacities Indoor High SpeedIndoor Low Speed IndoorCD5AB Size20.42 Coils + 355MAV060100 Variable Speed Furnace Coils +333B,JAV048080 Variable Speed Furnace Coils +333B,JAV036060 Variable Speed FurnaceCoils +333B,JAV060100 Variable Speed Furnace Coils +333B,JAV060120 Variable Speed Furnace11.99 Coils + 355MAV060100 Variable Speed Furnace Section Size Capacity Power Coils + 355MAV060120 Variable Speed Furnace 30.89 Size Capacity Power 71.35 39.02 KW† Indoor Outdoor Coil Entering AIR Temperatures FHeat Pump Heating Performance EDB CFMTotal Capacity Total Capacity MBtuh†Indoor Cooling Section Capacity Total MBtuh† Size Capacity Power Section048 See notes on Capacity Power Section Size Capacity Indoor Cooling Section Size CapacityCoils + 355MAV042060 Variable Speed Furnace Coils + 355MAV060100 Variable Speed Furnace 060 See notes on Capacity Power 20.48 Capacity Total Capacity Total MBtuh† Pwr System Design Page
Related manuals
Manual 16 pages 12.64 Kb

698B specifications

The Bryant 698B is an advanced residential air conditioning unit known for its efficiency and reliability in delivering optimal indoor climate control. Designed for comfort and energy savings, the Bryant 698B is a notable choice for homeowners seeking high-performance cooling solutions.

One of its standout features is its impressive Seasonal Energy Efficiency Ratio (SEER) rating, which ranges from 16 to 18, depending on the specific model. This high efficiency helps to reduce energy consumption while providing consistent cooling performance, allowing homeowners to enjoy a comfortable environment without incurring high electricity bills. The unit's efficient operation is recognized by various energy efficiency certifications, helping promote a more sustainable lifestyle.

The Bryant 698B is equipped with a variable-speed compressor, which adjusts its operating speed based on the cooling needs of the home. This technology allows the system to run at lower speeds for longer periods, ensuring a more consistent temperature throughout the space and reducing wear and tear on the system. This also minimizes noise levels, making the Bryant 698B one of the quieter units available today.

In terms of build quality, the Bryant 698B features a durable steel cabinet designed to withstand harsh weather conditions. The unit is treated with a baked-on powder finish that provides corrosion resistance, ensuring its longevity even in challenging environments. Additionally, the coil is designed for easy maintenance, allowing for optimal airflow and ensuring the system runs efficiently.

Smart technology integration is another highlight of the Bryant 698B. The unit can be connected to a smart thermostat, offering homeowners remote access to control their HVAC system from their smartphones. This capability allows for more precise temperature adjustments and scheduling, contributing to enhanced energy savings and increased comfort.

The Bryant 698B also offers various customizable options, including different cooling capacities and compatibility with additional heating systems like heat pumps or gas furnaces. This versatility makes it suitable for a wide range of residential applications.

In summary, the Bryant 698B air conditioning unit stands out due to its energy efficiency, variable-speed compressor, durable construction, smart technology features, and customization options, making it an ideal choice for homeowners looking for a robust and efficient cooling solution.