Eagle Electronics EGA200 Before Using this AIR Tool, Operating Instructions, Troubleshooting

Page 5

BEFORE USING THIS AIR TOOL

To ensure long life be sure to oil the tool daily. Pour 4 drops of Eagle air tool (SEA 20 non detergent) oil into the air inlet, and then run the tool for a few seconds to clean.

If tool is an impact wrench fitted with a “Zirc” grease fitting:

The hammer mechanism of this tool also needs to be greased from time to time (depending on usage). The tool is equipped with grease fitting for this purpose; use this connection to re-grease the tool using Eagle impact wrench grease.

PLEASE USE EAGLE SEA 20 NON DETERGENT OIL

OPERATING INSTRUCTIONS

This ratchet is designed to speed up productivity, not for high torque applications such as head bolts, lug nuts, etc. DO NOT USE THIS RATCHET UNDER POWER TO BREAK FASTENERS LOOSE. Loosen fasteners by hand without depressing throttle. Once loose depress throttle. Always perform final torque tightening by hand.

This ratchet is rated to 3/8” bolt size. Rating will decrease for U-bolts, long cap screws, spring fasteners and rusted or corroded fasteners. All these factors absorb power and reduce torque capability.

Use the simplest socket to wrench hook-up. Any additional extensions, U-joints or adapters will absorb power and reduce torque capability.

Forward/Reverse Lever - Select “F” for forward (clockwise) or “R” for reverse (counter clockwise) opera- tion. Do not attempt to change direction while tool is running.

If fastener bogs, slows or binds the tool (or, if the fastener fails to move in 5 seconds), use a large size impact wrench with a higher torque rating. Overloading this tool will cause premature wear and/or per- manent damage to internal and external drive parts and will void warranty.

TROUBLESHOOTING

SYMPTOMS

CAUSE

REMEDY

Air tool does not

Lack of lubrication.

Lubricate as per instructions.

run or runs slow.

 

 

 

 

 

 

Dirt in tool.

Clean with mixture of 50/50 tool

 

 

 

oil/solvent. Lubricate after cleaning.

 

 

 

 

Insufficient air pressure.

Check regulator and air supply for

 

 

 

leaks. Check compressor to make

 

 

sure it operates at correct pressure.

 

 

Make sure air hose is properly sized

 

 

and that multiple hoses are not

 

 

connected to same outlet. Check air

 

 

hose for leaks and repair.

 

Rotor blades worn or motor

Replace blades, inspect clean or

 

 

bearing worn or dirty.

replace bearing.

IMPACT WRENCH

See causes (above).

See remedies (above).

does not impact or

 

 

impacts slowly.

 

 

 

Broken or worn impact

Inspect and repair as required.

 

 

mechanism.

 

Wear hearing protection.

Wear eye protection.

Wear respiratory protection.

Read the instruction manual

Image 5
Contents Model EGA200 EagleLimited Air Tool Warranty Read the Entire Manual Before Putting this Tool in ServiceTable of Contents Safety Instructions Operating Instructions Before Using this AIR ToolTroubleshooting Index Part Description QTY Parts Breakdown75019 Ring 75020 Air compressors Air compressor parts Air powered accessories