Bryant 355MAV instruction manual Dimensions in, DimensionalDrawing

Models: 355MAV

1 60
Download 60 pages 27.74 Kb
Page 4
Image 4
Dimensions (in.)

 

 

26 1516"

 

 

 

 

28 12"

 

 

 

26 14"

 

AIRFLOW

 

 

26 1516"

 

 

24 12"

 

 

 

26 14"

 

 

 

 

 

 

 

22

5

16"

 

A

 

916"

22 516"

 

 

 

 

 

19"

1316"

2-IN. COMBUSTION-

13/16"

D

13/16"

CONDENSATE DRAIN

 

 

TYP

 

58"

AIR CONN

OUTLET

 

 

OUTLET

 

 

 

TRAP LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(DOWNFLOW &

 

CONDENSATE DRAIN

 

2-IN. COMBUSTION-

 

 

 

 

HORIZONTAL LEFT)

 

TRAP LOCATION

 

 

 

 

 

78-IN. DIA

 

(DOWNFLOW &

 

AIR CONN

516"

12-IN. DIA

POWER CONN

 

HORIZONTAL RIGHT)

 

12-IN. DIA

 

 

 

OR ALTERNATE

 

 

GAS CONN

 

 

12-IN. DIA GAS CONN

 

GAS CONN

 

2-IN. VENT CONN

 

 

 

 

78-IN. DIA

 

 

 

 

33 14"

 

 

 

 

 

 

 

 

 

 

POWER CONN

 

1

 

 

 

 

 

 

 

 

 

 

 

 

32 58" TYP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-IN. DIA THERMOSTAT

 

 

 

 

 

30 1316" TYP

12-IN. DIA

 

 

ENTRY

78-IN. DIA

 

 

 

 

THERMOSTAT ENTRY

 

 

22 1116"

 

 

 

 

 

 

30 12"

 

2-IN. VENT CONN

39 78"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORY

 

 

 

 

29 1116"

 

 

 

 

 

 

 

 

 

 

POWER ENTRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 58" TYP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSATE

 

 

 

22 1116"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN TRAP

 

 

27

916"

 

 

 

 

 

 

 

 

 

 

 

 

LOCATION

 

 

TYP

 

 

 

 

 

 

 

 

 

 

 

 

(ALTERNATE

24

12"

 

 

 

 

 

 

 

 

 

 

 

 

UPFLOW)

 

 

 

 

 

14 12"

SIDE INLET

17 516"

 

 

 

18 14"

SIDE INLET

 

 

TYP

 

 

 

 

 

 

 

 

 

 

 

9 716"

 

 

 

 

 

 

 

 

 

 

 

TYP

 

 

 

 

 

1"

1

1

4"

 

 

 

INLET

 

CONDENSATE

22 14" TYP

716"

 

CONDENSATE

 

 

 

 

23 14" TYP

11/16"

E

11/16"

DRAIN LOCATION

4

1"

 

 

 

 

 

 

SIDE INLET

DRAIN LOCATION

 

 

 

(UPFLOW)

 

 

 

 

 

(UPFLOW)

 

 

 

DIMPLE LOCATORS

24 316"

1116"

 

 

 

 

 

 

 

 

 

 

 

26 1516" TYP

 

 

 

 

BOTTOM INLET

 

 

 

 

 

 

 

 

 

 

FOR HORIZONTAL

 

 

 

 

 

 

 

 

 

 

 

HANGING

 

 

NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.

2.Minimum return-air opening at furnace:

a.For 800 CFM–16-in. round or 141/2 x 12-in. rectangle.

b.For 1200 CFM–20-in. round or 141/2 x 191/2-in. rectangle.

c.For 1600 CFM–22-in. round or 141/2 x 231/4-in. rectangle.

d.For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

A99112

Dimensions (in.)

UNIT SIZE

A

D

E

 

 

 

 

042040*

24-1/2

22-7/8

23*

042060

17-1/2

15-7/8

16

042080

21

19-3/8

19-1/2

060080

21

19-3/8

19-1/2

060100

21

19-3/8

19-1/2

060120

24-1/2

22-7/8

23

* These dimensions reflect the wider casing for the Trophy (96.6 percent AFUE) furnace.

Fig. 2—Dimensional Drawing

Page 4
Image 4
Bryant 355MAV instruction manual Dimensions in, DimensionalDrawing