| 26 15⁄16" |
|
|
|
| 28 1⁄2" |
|
|
| 26 1⁄4" |
| AIRFLOW |
|
| 26 15⁄16" |
|
| 24 1⁄2" |
|
|
| 26 1⁄4" |
| ||
|
|
|
|
|
| |||
22 | 5 | ⁄16" |
| A |
| 9⁄16" | 22 5⁄16" |
|
|
|
|
| 19" | 13⁄16" | |||
13/16" | D | 13/16" | ||||||
CONDENSATE DRAIN |
|
| TYP |
| 5⁄8" | |||
AIR CONN | OUTLET |
|
| OUTLET | ||||
|
|
| TRAP LOCATION |
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| (DOWNFLOW & |
| CONDENSATE DRAIN |
|
| |
|
|
| HORIZONTAL LEFT) |
| TRAP LOCATION |
|
| |
|
|
|
| (DOWNFLOW & |
| AIR CONN | 5⁄16" | |
POWER CONN |
| HORIZONTAL RIGHT) |
|
| ||||
|
| OR ALTERNATE |
|
| ||||
GAS CONN |
|
|
| GAS CONN |
| |||
|
|
|
|
| ||||
|
|
| 33 1⁄4" |
|
|
|
| |
|
|
|
|
|
| POWER CONN |
|
1 |
|
|
|
|
|
|
|
|
|
|
|
| 32 5⁄8" TYP |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
| 30 13⁄16" TYP |
| ||||||||||||||||
| ENTRY |
|
|
|
| THERMOSTAT ENTRY |
| |||||||||||||||
| 22 11⁄16" |
|
|
|
|
|
| 30 1⁄2" |
| 39 7⁄8" | ||||||||||||
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
| ACCESSORY |
|
|
|
| 29 11⁄16" |
|
| |||||||
|
|
|
|
|
|
|
| POWER ENTRY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 27 5⁄8" TYP |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| CONDENSATE |
|
|
| 22 11⁄16" |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| DRAIN TRAP |
|
| 27 | 9⁄16" |
|
|
|
| ||||||
|
|
|
|
|
|
|
| LOCATION |
|
| TYP |
|
|
|
| |||||||
|
|
|
|
|
|
|
| (ALTERNATE | 24 | 1⁄2" |
|
|
|
| ||||||||
|
|
|
|
|
|
|
| UPFLOW) |
|
|
|
|
| 14 1⁄2" | SIDE INLET | 17 5⁄16" |
|
|
| 18 1⁄4" | SIDE INLET |
| ||
| TYP |
|
|
|
|
|
| ||||
|
|
|
|
| 9 7⁄16" |
|
|
|
|
|
|
|
|
|
|
| TYP |
|
|
|
|
| 1" |
— | 1 | 1 | ⁄4" |
|
|
| INLET |
| CONDENSATE | 22 1⁄4" TYP | 7⁄16" |
| CONDENSATE |
|
|
| |||||||
| 23 1⁄4" TYP | 11/16" | E | 11/16" | DRAIN LOCATION | ||||||
4 | 1" |
|
|
| |||||||
— |
|
|
| SIDE INLET | DRAIN LOCATION |
|
|
| (UPFLOW) |
|
|
|
|
| (UPFLOW) |
|
|
| DIMPLE LOCATORS | 24 3⁄16" | 11⁄16" | ||
|
|
|
|
|
|
| |||||
|
|
|
| 26 15⁄16" TYP |
|
|
|
| BOTTOM INLET |
| |
|
|
|
|
|
|
|
|
| FOR HORIZONTAL |
|
|
|
|
|
|
|
|
|
|
| HANGING |
|
|
NOTES: 1. Minimum
2.Minimum
a.For 800
b.For 1200
c.For 1600
d.For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
A99112
Dimensions (in.)
UNIT SIZE | A | D | E |
|
|
|
|
042040* | 23* | ||
042060 | 16 | ||
042080 | 21 | ||
060080 | 21 | ||
060100 | 21 | ||
060120 | 23 |
* These dimensions reflect the wider casing for the Trophy (96.6 percent AFUE) furnace.