Table
Ambient*
| WINTER DESIGN | MAXIMUM PIPE |
| INSTALLATION THICKNESS | ||
UNIT |
|
| (IN.) | |||
TEMPERATURE | DIAMETER |
|
| |||
SIZE |
|
|
| 1/2 or THICKER | ||
(°F) | (IN.) | 0 | 3/8 |
| ||
|
| INSTALLATION† | ||||
|
|
|
|
|
| |
| 20 | 2 | 30 | 70 |
| 70 |
| 0 | 2 | 12 | 53 |
| 64 |
042040 | 2 | 2 | 36 |
| 45 | |
20 | 34 | 50 |
| 50 | ||
|
| |||||
| 0 | 17 | 50 |
| 50 | |
| 8 | 46 |
| 50 | ||
| 20 | 2 | 44 | 70 |
| 70 |
| 0 | 2 | 21 | 70 |
| 70 |
042060 | 2 | 9 | 57 |
| 69 | |
20 | 50 | 70 |
| 70 | ||
|
| |||||
| 0 | 27 | 70 |
| 70 | |
| 16 | 70 |
| 70 | ||
| 20 | 2 | 57 | 70 |
| 70 |
| 0 | 2 | 30 | 70 |
| 70 |
042080 | 2 | 16 | 70 |
| 70 | |
060080 | 20 | 64 | 70 |
| 70 | |
| 0 | 37 | 70 |
| 70 | |
| 23 | 70 |
| 70 | ||
| 20 | 70 | 70 |
| 70 | |
| 0 | 38 | 70 |
| 70 | |
060100 | 21 | 70 |
| 70 | ||
20 | 2 | 70 | 70 |
| 70 | |
|
| |||||
| 0 | 2 | 38 | 70 |
| 70 |
| 2 | 23 | 70 |
| 70 | |
| 20 | 3 | 70 | 70 |
| 70 |
060120 | 0 | 3 | 38 | 70 |
| 70 |
| 3 | 19 | 70 |
| 70 | |
|
|
|
|
|
|
|
*Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in Table 8.
† Insulation thickness based on R value of 3.5 (ft_ • °F• hr)/(Btu•in.)
b.Termination kit should be positioned where vent vapors will not damage plants/shrubs or air conditioning equipment.
c.Termination kit should be positioned so it will not be affected by wind eddy (such as inside building comers) or that may allow recirculation of flue gases, airborne leaves, or light snow.
d.Termination kit should be positioned where it will not be damaged by or subjected to foreign objects, such as stones, balls, etc.
e.Termination kit should be positioned where vent vapors are not objectionable.
2.Cut one
3.Loosely assemble concentric vent/air termination components together using instructions in kit.
4.Slide assembled kit with rain shield REMOVED through hole.
Roof
Sidewall
5.Disassemble loose pipe fittings. Clean and cement using same procedures as used for system piping.
6.Check required dimensions as shown in Fig. 40 or 41.
D. Multiventing and Vent Terminations
When 2 or more 355MAV furnaces are vented near each other, each furnace must be individually vented. NEVER common vent or breach vent 355MAV furnaces. When 2 or more 355MAV furnaces are vented near each other, 2 vent terminations may be installed as shown in Fig. 44, 45, 46, 47, or 48, but the next vent termination must be at least 36 in. away from first 2 terminations. It is important that vent terminations be made as shown to avoid recirculation of flue gases. Dimension A in Fig. 44, 45, 46, 47, and 48 represents distance between pipes or rain shields, as touching or
PROCEDURE 10—CONDENSATE DRAIN
A. General
Condensate trap is shipped installed in the blower shelf and factory connected for UPFLOW applies Condensate trap must be RELOCATED for use in DOWNFLOW and HORIZONTAL applications.
Condensate trap MUST be used for all applications.