PLUG
CAP
COLLECTOR BOX DRAIN TUBE (BLUE & WHITE STRIPED)
COLLECTOR BOX TUBE (PINK)
COLLECTOR BOX
TUBE (GREEN)
COLLECTOR BOX
DRAIN TUBE (GREEN)
CONDENSATE
TRAP
INDUCER HOUSING DRAIN TUBE (VIOLET)
A94214
Fig.
NOTE: Failure to use CPVC elbows may allow drain to kink and prevent draining.
f.Connect larger diameter drain tube and clamp
g.Route tube to coupling and cut to appropriate length.
h.Attach tube to coupling and clamp securely.
C. Condensate Trap Location (Alternate Upflow Orientation)
An alternate location for the condensate trap is the
NOTE: If the alternate
To relocate condensate trap to the
1.Remove 3 tubes connected to condensate trap.
2.Remove trap from blower shelf by gently pushing tabs inward and rotating trap.
3.Install casing hole filler cap
4.Install condensate trap into
5.Fill unused condensate trap casing holes with plastic filler caps
D. Condensate Trap Tubing (Alternate Upflow Orientation)
NOTE: See Fig. 6 or tube routing label on main furnace door to confirm location of these tubes.
1.Collector Box Drain Tube
Connect collector box drain tube (blue label) to condensate trap.
NOTE: On
2.Inducer Housing Drain Tube
a.Remove and discard LOWER (molded) inducer housing drain tube which was previously connected to condensate trap.
b.Use inducer housing drain extension tube (violet label and
c.Determine appropriate length, cut, and connect tube.
d.Clamp tube to prevent any condensate leakage.
3.Relief Port Tube