![Fig. 29—Relocating J-Box](/images/new-backgrounds/47908/4790853x1.webp)
ALTERNATE FIELD LOCATION
FACTORY
INSTALLED
LOCATION
A00212
Fig. 29—Relocating J-Box
NOTE: If desired, cut butt connectors off factory leads and strip insulation approximately 1/4 in and use
b.An alternate method to attach EAC lead to control center is the following procedure: (1.) Remove 2 screws securing the control box to furnace blower shelf.
(2.) Remove and discard 2
(3.) Strip EAC power leads insulation approximately 1/8 in.
NOTE: The control center EAC terminals are sized for 12 gage maximum, solid or stranded wire. (4.) Route EAC leads through
(5.) Insert EAC stripped leads into control center EAC terminals by depressing terminal’s arm with a screwdriver or finger. (See Fig. 32.)
(6.) Reinstall control box to furnace blower shelf using 2 screws removed earlier.
2.Humidifier (HUM)
Screw terminals (HUM and COM) are provided for
NOTE: A
3.Dehumidification (DEHUM)
A dehumidification input is provided via a
The DEHUM output on the thermidistat control or the humidistat output is connected directly to the DEHUM terminal on the furnace control. In addition, the DE jumper located next to the DEHUM terminal must be removed to enable the DEHUM input. (See Fig. 33 and 34.) When a dehumidify demand exists, the furnace control reduces the blower airflow by 21 percent to 315 CFM per ton during continuous fan or cooling operation.
PROCEDURE 9—DIRECT VENTING
The 355MAV furnaces require a dedicated (one 355MAV furnace only)
A. Removal of Existing Furnaces from Common Vent Systems
If furnace being replaced was connected to a common vent system with other appliances, the following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation:
1.Seal any unused openings in the venting system.
2.Inspect the venting system for proper size and horizontal pitch as required in the National Fuel Gas Code, ANSI Z223.1 or 24 the CAN/CGA B149 Installation Codes and these instructions. Determine that there is no blockage or restriction, leakage, corrosion, and other deficiencies which could cause an unsafe condition.
3.If practical, close all building doors and windows and all doors between the space in which the appliance(s) connected to the venting system are located and other spaces of the building. Turn on clothes dryers and any appliance not connected to the venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers.