Bryant manual 223A*A060---B Outdoor Section With FY4ANF060 Indoor Section, 1750, 2000, 2250

Page 46

223A

DETAILED COOLING CAPACITIES# CONTINUED

EVAPORATOR AIR

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)

 

 

 

 

 

 

 

 

 

 

75 (23.9)

 

 

85 (29.4)

 

 

95 (35)

 

 

105 (40.6)

 

 

 

115 (46.1)

 

 

125 (51.7)

 

CFM

EWB

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

 

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

 

 

Sys.

 

 

Sys.

 

 

 

Sys.

 

 

 

Sys.

 

 

Sys.

 

 

Sys.

° F (° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

 

Sens‡

KW**

Total

Sens‡

 

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

223A*A060---B Outdoor Section With FY4ANF060 Indoor Section

 

 

 

 

 

 

 

 

72 (22.2)

71.08

36.09

4.41

67.69

34.77

4.86

64.09

 

33.39

5.36

60.33

31.96

 

5.90

56.30

30.45

6.50

51.84

28.81

7.14

 

67 (19.4)

65.19

45.05

4.36

62.05

43.69

4.81

58.73

 

42.27

5.30

55.30

40.82

 

5.85

51.61

39.29

6.44

47.57

37.62

7.09

1750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

60.79

43.67

4.31

57.85

42.31

4.76

54.78

 

40.90

5.26

51.57

39.45

 

5.81

48.15

37.91

6.40

44.41

36.26

7.05

 

62 (16.7)

59.61

53.90

4.30

56.75

52.49

4.75

53.77

 

51.00

5.25

50.69

49.41

 

5.80

47.50

47.50

6.40

45.90

45.90

6.36

 

57 (13.9)

57.48

57.48

4.28

55.20

55.20

4.74

52.79

 

52.79

5.24

50.24

50.24

 

5.79

47.49

47.49

6.40

44.42

44.42

7.06

 

72 (22.2)

72.12

37.62

4.54

68.55

36.26

4.99

64.87

 

34.89

5.48

60.98

33.44

 

6.03

56.80

31.91

6.62

52.19

30.25

7.26

 

67 (19.4)

66.24

47.72

4.48

62.96

46.34

4.93

59.50

 

44.89

5.43

55.93

43.42

 

5.97

52.11

41.85

6.57

47.93

40.14

7.21

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

61.83

46.19

4.44

58.77

44.80

4.89

55.56

 

43.36

5.38

52.22

41.88

 

5.93

48.67

40.31

6.53

44.80

38.60

7.18

 

62 (16.7)

60.73

57.58

4.43

57.79

56.05

4.88

54.77

 

54.33

5.38

51.88

51.88

 

5.93

48.94

48.94

6.53

47.37

47.37

6.51

 

57 (13.9)

59.63

59.63

4.42

57.18

57.18

4.87

54.60

 

54.60

5.38

51.89

51.89

 

5.93

48.94

48.94

6.53

45.66

45.66

7.19

 

72 (22.2)

72.83

39.05

4.66

69.16

37.69

5.11

65.40

 

36.31

5.61

61.39

34.85

 

6.15

57.10

33.30

6.74

52.35

31.61

7.37

 

67 (19.4)

66.96

50.26

4.61

63.58

48.86

5.06

60.01

 

47.39

5.55

56.35

45.89

 

6.09

52.43

44.28

6.69

48.14

42.52

7.33

2250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

62.58

48.57

4.56

59.40

47.16

5.01

56.09

 

45.69

5.51

52.66

44.18

 

6.05

49.01

42.56

6.65

45.05

40.80

7.30

 

62 (16.7)

61.68

60.83

4.56

58.79

58.79

5.01

56.05

 

56.05

5.51

53.19

53.19

 

6.06

50.08

50.08

6.66

46.62

46.62

7.31

 

57 (13.9)

61.37

61.37

4.55

58.79

58.79

5.01

56.06

 

56.06

5.51

53.19

53.19

 

6.06

50.08

50.08

6.66

46.62

46.62

7.31

46

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

 

 

 

 

*FY4ANB060

1.00

1.00

 

FE4ANB006

1.01

0.95

 

FV4BNB006

1.01

0.95

 

FX4CN(B,F)060

1.01

0.91

 

CAP**6021A**

0.99

0.99

 

CAP**6024A**

1.01

1.01

 

CNPH*6024A**

1.00

1.00

 

CNPV*6024A**

1.00

1.00

 

CSPH*6012A**

1.01

1.01

 

CAP**6021A**

0.97

0.94

315(A,J)AV060110

CNPH*6024A**

0.98

0.95

315(A,J)AV060110

CSPH*6012A**

0.99

0.96

315(A,J)AV060110

CAP**6024A**

0.99

0.93

315(A,J)AV066135

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

 

 

 

 

CNPH*6024A**

0.98

0.95

315(A,J)AV066135

CNPV*6024A**

0.98

0.95

315(A,J)AV066135

CSPH*6012A**

0.99

0.93

315(A,J)AV066135

CAP**6024A**

0.99

0.93

315(A,J)AV066155

CNPH*6024A**

0.99

0.93

315(A,J)AV066155

CNPV*6024A**

0.99

0.93

315(A,J)AV066155

CSPH*6012A**

0.99

0.93

315(A,J)AV066155

CNPH*6024A**

0.97

0.91

353AAV048080

CSPH*6012A**

0.97

0.92

353AAV048080

CAP**6021A**

0.97

0.92

353AAV060100

CNPH*6024A**

0.97

0.92

353AAV060100

CSPH*6012A**

0.98

0.92

353AAV060100

CAP**6024A**

0.97

0.92

353AAV060120

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

 

 

 

 

CNPH*6024A**

0.97

0.92

353AAV060120

CNPV*6024A**

0.97

0.92

353AAV060120

CSPH*6012A**

0.98

0.92

353AAV060120

CAP**6021A**

0.98

0.92

313*AV048090

CNPH*6024A**

0.98

0.92

313*AV048090

CSPH*6012A**

0.99

0.93

313*AV048090

CAP**6021A**

0.99

0.93

313*AV060110

CNPH*6024A**

0.98

0.92

313*AV060110

CSPH*6012A**

0.99

0.93

313*AV060110

CAP**6024A**

0.98

0.92

313*AV060135

CNPH*6024A**

0.98

0.92

313*AV060135

CNPV*6024A**

0.98

0.92

313*AV060135

CSPH*6012A**

0.99

0.93

313*AV060135

{Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

}Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh

(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).

#Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

Image 46
Contents Industry Leading Features / Benefits Product DataModel Number Nomenclature Standard FeaturesSeer Liquid Line Physical DataVapor Line Total Equivalent Line Length ft. m BtuhAccessories NumberPHP Accessory ThermostatsNHP Accessory Description and Usage Listed Alphabetically Or CKT Electrical Data018---C Dimensions English Dimensions SI Outdoor TEMPERATURE, ºF ºC Wall 152.4 mm 609.6 304.8 Service Combination Ratings Combination Ratings FF1ENP036 FY4ANF03630000 14.0 11.5 18000 3058043 223APA030---B Combination Ratings †FY4ANF030 30000 13.0 10.8 18700 3035143 FY4ANF042 Combination Ratings 33800 14.0 11.5 34600 21000 3035237 223ANA036---C Combination Ratings †FY4ANF036 33800 13.0 10.5 35600 21800 3035354 3035270 FV4BNB006 FE4ANB006+UIFY4ANF048 Combination Ratings Combination Ratings Combination Ratings Combination Ratings Combination Ratings Combination Ratings FY4ANB060 Combination Ratings Combination Ratings Combination Ratings 60000 14.0 11.5 58500 36200 3036240 223AEA060---B 60000 14.0 11.5 58500 36200 3036210 223APA060---B Detailed Cooling CAPACITIES# 223A*A018---C Outdoor Section With FY4ANF018 Indoor Section800 223A*A024---B Outdoor Section With FY4ANF024 Indoor Section700 9001000 Outdoor Section With FY4ANF030 Indoor Section875 1125Detailed Cooling CAPACITIES# 1200 223A*A036---C Outdoor Section With FY4ANF036 Indoor Section1050 1350Detailed Cooling CAPACITIES# 1400 223A*A042---B Outdoor Section With FY4ANF042 Indoor Section1225 1575Detailed Cooling CAPACITIES# 1600 223A*A048---B Outdoor Section With FY4ANF048 Indoor Section1800 2000 223A*A060---B Outdoor Section With FY4ANF060 Indoor Section1750 2250Heat Pump Heating Performance Section With FY4ANF018 Indoor SectionFE4ANF002 FF1ENP024 FF1ENP030 FV4BNF002 FX4CNF024 FX4CNF030 FY4ANF030FE4ANF002 FF1ENP030 FF1ENP036 FX4CNF030 FY4ANF036Heat Pump Heating Performance Section With FY4ANF036 Indoor Section 223A*A036---C Outdoor Section With FY4ANF036 Indoor Section FE4ANB006 FE4ANF003 FE4ANF005 FV4BNB006 FV4BNF003 FV4BNF005 Section With FY4ANF042 Indoor Section223A*A042---B Outdoor Section With FY4ANF042 Indoor Section FY4ANF048 FE4ANB,F005 Heating Indoor Capacity Guide Specifications General System DescriptionCatalog No. PDS223A---05
Related manuals
Manual 8 pages 62.26 Kb Manual 10 pages 44.99 Kb

223A specifications

The Bryant 223A is a cutting-edge air conditioning unit that epitomizes modern cooling technology. Designed for both residential and commercial applications, this model stands out for its efficiency, reliability, and user-friendly features. One of the most significant aspects of the Bryant 223A is its energy efficiency, boasting a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16. This high rating means lower energy consumption, translating into reduced utility bills for homeowners and businesses alike.

One prominent feature of the Bryant 223A is its environmentally friendly design. It utilizes Puron refrigerant, which has zero ozone-depleting potential, making it a responsible choice for those looking to minimize their environmental footprint. In addition to being eco-conscious, the unit is equipped with a variable-speed compressor, allowing for improved humidity control and enhanced comfort levels. This technology enables the system to adjust its cooling output based on the current indoor conditions, resulting in more consistent temperatures and quieter operation.

Another noteworthy characteristic of the Bryant 223A is its robust construction. The cabinet is designed with galvanized steel, offering durability and resistance to corrosion. This resilience ensures that the unit can withstand the rigors of various weather conditions, contributing to its longevity. Moreover, the unit features an innovative design that minimizes noise levels, ensuring that it operates quietly without disturbing daily activities.

Ease of installation is yet another advantage of the Bryant 223A. The unit comes with a compact design, allowing for straightforward placement in a variety of settings. Additionally, its integration with modern smart thermostats provides users with enhanced control over their indoor climate. This feature enables homeowners to monitor and adjust their air conditioning settings remotely, adding convenience and efficiency to their energy management.

The Bryant 223A also incorporates advanced filtration systems, which significantly improve indoor air quality. Enhanced filters capture a wide range of airborne particles, including allergens, dust, and pollutants, making it an excellent choice for households with allergy sufferers. Overall, the Bryant 223A combines state-of-the-art technology, eco-friendly operation, and user-centric features, making it a leading choice in air conditioning solutions for a variety of environments.