Bryant 223A manual Accessory Description and Usage Listed Alphabetically

Page 6

Accessory Description and Usage (Listed Alphabetically) - CONTINUED

223A

5. Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

6. Isolation Relay

An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.

Usage Guideline:

Required in all heat pumps where low ambient kit has been added.

7. Liquid-Line Solenoid Valve (LLS)

An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode.

Usage Guideline:

An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.

8. Low-Ambient Pressure Switch Kit

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low-ambient temperatures down to 0_F (-17.8_C)when properly installed.

Usage Guideline:

ALow-Ambient Pressure Switch or MotorMasterr Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

9.MotorMasterr Low-Ambient Controller

Afan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 6.5_C).

Usage Guideline:

A MotorMasterr Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

Suggested for all commercial applications.

10. Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

11. Outdoor Thermostat

An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point.

Usage Guideline:

Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired.

12. Secondary Outdoor Thermostat

An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point.

Usage Guideline:

Outdoor thermostat applications where electric heater is capable of three-stage operation.

13. Snow Stand

Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base.

Usage Guideline:

Suggested in the following applications:

Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations.

Heat pump installations in areas of prolonged subfreezing temperatures.

All commercial installations.

14. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.

Usage Guideline:

 

Suggested when unit is installed closer than 15 ft.

 

(4.577 m) to quiet areas, bedrooms, etc.

 

Suggested when unit is installed between two houses

less

than 10 ft. (3.05 m) apart.

15. Thermostatic Expansion Valve (TXV) Bi-Flow

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Usage Guideline:

Accessory required to meet ARI rating and system reliability, where indoor not equipped.

Required in all heat pump applications designed with Puron refrigerant.

16. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

Accessory required to meet ARI rating, where indoor not equipped.

6

Image 6
Contents Industry Leading Features / Benefits Product DataStandard Features Model Number NomenclatureSeer Liquid Line Physical DataVapor Line Total Equivalent Line Length ft. m BtuhAccessories NumberAccessory Thermostats PHPNHP Accessory Description and Usage Listed Alphabetically Electrical Data Or CKT018---C Dimensions English Dimensions SI Outdoor TEMPERATURE, ºF ºC Wall 152.4 mm 609.6 304.8 Service Combination Ratings Combination Ratings FF1ENP036 FY4ANF03630000 14.0 11.5 18000 3058043 223APA030---B Combination Ratings †FY4ANF030 30000 13.0 10.8 18700 3035143 FY4ANF042 Combination Ratings 33800 14.0 11.5 34600 21000 3035237 223ANA036---C Combination Ratings †FY4ANF036 33800 13.0 10.5 35600 21800 3035354 3035270 FE4ANB006+UI FV4BNB006FY4ANF048 Combination Ratings Combination Ratings Combination Ratings Combination Ratings Combination Ratings Combination Ratings FY4ANB060 Combination Ratings Combination Ratings Combination Ratings 60000 14.0 11.5 58500 36200 3036240 223AEA060---B 60000 14.0 11.5 58500 36200 3036210 223APA060---B Detailed Cooling CAPACITIES# 223A*A018---C Outdoor Section With FY4ANF018 Indoor Section800 223A*A024---B Outdoor Section With FY4ANF024 Indoor Section700 9001000 Outdoor Section With FY4ANF030 Indoor Section875 1125Detailed Cooling CAPACITIES# 1200 223A*A036---C Outdoor Section With FY4ANF036 Indoor Section1050 1350Detailed Cooling CAPACITIES# 1400 223A*A042---B Outdoor Section With FY4ANF042 Indoor Section1225 1575Detailed Cooling CAPACITIES# 223A*A048---B Outdoor Section With FY4ANF048 Indoor Section 16001800 2000 223A*A060---B Outdoor Section With FY4ANF060 Indoor Section1750 2250Heat Pump Heating Performance Section With FY4ANF018 Indoor SectionFE4ANF002 FF1ENP024 FF1ENP030 FV4BNF002 FX4CNF024 FX4CNF030 FY4ANF030FE4ANF002 FF1ENP030 FF1ENP036 FX4CNF030 FY4ANF036Heat Pump Heating Performance Section With FY4ANF036 Indoor Section 223A*A036---C Outdoor Section With FY4ANF036 Indoor Section FE4ANB006 FE4ANF003 FE4ANF005 FV4BNB006 FV4BNF003 FV4BNF005 Section With FY4ANF042 Indoor Section223A*A042---B Outdoor Section With FY4ANF042 Indoor Section FY4ANF048 FE4ANB,F005 Heating Indoor Capacity Guide Specifications General System DescriptionCatalog No. PDS223A---05
Related manuals
Manual 8 pages 62.26 Kb Manual 10 pages 44.99 Kb

223A specifications

The Bryant 223A is a cutting-edge air conditioning unit that epitomizes modern cooling technology. Designed for both residential and commercial applications, this model stands out for its efficiency, reliability, and user-friendly features. One of the most significant aspects of the Bryant 223A is its energy efficiency, boasting a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16. This high rating means lower energy consumption, translating into reduced utility bills for homeowners and businesses alike.

One prominent feature of the Bryant 223A is its environmentally friendly design. It utilizes Puron refrigerant, which has zero ozone-depleting potential, making it a responsible choice for those looking to minimize their environmental footprint. In addition to being eco-conscious, the unit is equipped with a variable-speed compressor, allowing for improved humidity control and enhanced comfort levels. This technology enables the system to adjust its cooling output based on the current indoor conditions, resulting in more consistent temperatures and quieter operation.

Another noteworthy characteristic of the Bryant 223A is its robust construction. The cabinet is designed with galvanized steel, offering durability and resistance to corrosion. This resilience ensures that the unit can withstand the rigors of various weather conditions, contributing to its longevity. Moreover, the unit features an innovative design that minimizes noise levels, ensuring that it operates quietly without disturbing daily activities.

Ease of installation is yet another advantage of the Bryant 223A. The unit comes with a compact design, allowing for straightforward placement in a variety of settings. Additionally, its integration with modern smart thermostats provides users with enhanced control over their indoor climate. This feature enables homeowners to monitor and adjust their air conditioning settings remotely, adding convenience and efficiency to their energy management.

The Bryant 223A also incorporates advanced filtration systems, which significantly improve indoor air quality. Enhanced filters capture a wide range of airborne particles, including allergens, dust, and pollutants, making it an excellent choice for households with allergy sufferers. Overall, the Bryant 223A combines state-of-the-art technology, eco-friendly operation, and user-centric features, making it a leading choice in air conditioning solutions for a variety of environments.