Extension Tables

1.Mount a cast iron table to the edge of the main table with three M8 x 25 hex cap screws (Figure 9) using a 12mm wrench. Do not fully tighten yet.

2.The extension table must be leveled with the main table. Place a straight edge (such as a jointed board) across the extension table and the main table.

NOTE: The straight edge should not lie over the raised table rollers, as this would distort the leveling process. Either place the straight edge just short of the table rollers, or lower the table rollers completely into the table (see page 11) while mounting the extension tables.

3.Insert three socket set screws with a 4mm hex wrench, and screw them in or out as needed until tables are level.

4.Securely tighten the hex cap screws.

5.Mount the second extension table to the opposite side of the planer table, using the same procedure.

Dust Hood

Mount the dust hood to the rear of the head casting with three M6 x 12 socket head cap screws with lock washers, and three M5 x 10 hex cap screws with flat washers. See Figure 10.

It is recommended that you use a dust collection system with this planer. If you are not using a dust collection system, do not attach the dust hood to the planer, as the accumulation of dust inside the hood may create a safety hazard, or eventually cause jamming of the rollers.

Electrical Connections

Electrical connections must be made by a qualified electrician in compliance with all relevant codes. The machine must be properly grounded to help prevent electrical shock and possible fatal injury.

A power plug is not provided with the 15S or 15HH planers. You may either connect a 230 volt plug or "hard-wire" the machine directly to your electrical panel provided there is a disconnect near the machine. Consult electrical schematic on page 38 for further clarification of wiring setup.

Figure 9

Figure 10

It is recommended that the 15S or 15HH Planer be connected to a dedicated, minimum 40 amp circuit with a 40 amp circuit breaker or time delay fuse. Local codes take precedence over recommendations.

9

Image 9
Contents Part No. M-0460286 Walter Meier Manufacturing, IncMore Information Warranty and ServiceTable of Contents Page Page 15HH Features SpecificationsUnpacking Crate Contents FigureInstallation and Assembly HandwheelStarter Box Extension Tables Dust HoodElectrical Connections Extension Cords AdjustmentsBelt Tension Recommended Gauges AWG of Extension CordsTable Rollers Pulley AlignmentReplacing Knives Model 15S only CutterheadModel 15HH only Replacing or Rotating Knife Inserts Model 15HH onlyKnow the Transmitting Rollers of Your Planer Work Table Parallel to CutterheadAnti-Kickback Fingers Infeed and Outfeed Roller Spring TensionHeight of Infeed Roller, Chipbreaker Outfeed Roller Outfeed Roller Height Infeed Roller HeightChipbreaker Height Chip Deflector Feed Speed ControlStock Return Rollers Depth of Cut MaintenanceLubrication Gearbox LubricantFigure No Functions of the Digital Scale Model 15S only Establish Absolute Zero Scale AlignmentUsing Relative Measurement Mode Clearing a Jammed BoardMore Uses Troubleshooting Performance Problems TroubleProbable Cause Remedy Troubleshooting Mechanical and Electrical Problems Examine motor starter for burned or Switch Lock Troubleshooting Digital Scale Model 15S onlyOptional Accessories Replacement PartsHead Assembly Index No. Part No Description Size Qty Parts List Head Assembly6284828 Base Assembly Index No Description Size Qty Parts List Base AssemblyTable Assembly Parts List Table Assembly Gearbox Assembly Parts List Gearbox Assembly Cabinet Assembly Parts List Cabinet Assembly Electrical Connections Single Phase, 230 Volt Preventive Maintenance New Sanford Road LaVergne, TN Phone