Ryobi AP1301 manual Brush Replacement, Cleaning, Brush Brush CAP

Page 19

MAINTENANCE

nUsing the open-end wrench, carefully loosen the blade locking screws ( 1 ).

nUsing the notched end of the magnetic blade wrench, remove the blade from the cutter head by hooking the notch over the end of the blade and pulling straight out. Use the magnet on the other end of the tool to help re- move the blade from the planer ( 2 ).

nIf you are changing to the second edge of the blade, rotate the blade “end for end” keeping the same flat side down. This will correctly position the blade to reinstall.

NOTE: Blades should be cleaned of gum and pitch before reinstalling.

nIf you are installing a new set of cutter blades, lightly oil each blade before installing.

nPlace blade into the opening on the cutter head and push in firmly to seat. Visually check that the blade edge is parallel to the cutter head slot.

nRetighten the blade locking screws securely.

nDepress the cutter lock lever and begin to rotate the cut- ter head to the next blade. Release the lock lever once the cutter head begins to rotate and continue to rotate until the lock engages and the second blade is in correct position for removal.

nReplace second blade using the same procedures as outlined above.

nReplace the dust hood and reinstall thumb screws to secure.

BRUSH REPLACEMENT

See Figure 13.

Externally accessible brush assemblies are located at the right front and the left rear of the planer. These brushes should be inspected every 10 to 15 operating hours for wear. Replace both brushes when either brush has less than 1/4 in. of carbon remaining.

NOTE: The dust hood may be removed for easier access when removing the rear brush cap.

nUnplug planer and remove the switch key.

nUsing a flat-head screwdriver, unscrew the brush cap. The brush assembly is spring-loaded and will pop out when you remove the cap.

nRemove the brush assembly (brush and spring) and inspect for wear. If less than 1/4 in. of carbon remains on brush, replace both brush assemblies. Never replace one side without replacing the other.

nInstall new brush assembly, if required, or reinstall old brush assembly.

nReplace cap and tighten to secure.

BRUSH

BRUSH CAP

Fig. 13

CLEANING

Sawdust buildup and other debris can cause the tool to plane inaccurately. Periodic cleaning and waxing is needed for accurate, precision planing.

Do not allow sawdust to accumulate on the planer. Clean the dust hood after each use.

DANGER:

Rotating blades under dust hood. In order to avoid personal injury, keep fingers away.

Moving parts should be cleaned regularly with penetrating oil and lubricated with a light coating of medium-weight machine oil.

Paste wax should be applied to the planing table surface to ease the movement of workpieces across it, but be careful not to use so much that it will be absorbed into the wood and interfere with staining.

Check feed rollers after each use for resin buildup, because feed rollers must be clean to be effective. If buildup occurs, use a mild, nonflammable tar and pitch remover.

19

Image 19
Contents Save this Manual for Future Reference OPERATOR’S ManualIntroduction WarrantyRead ALL Instructions General Safety RulesInspect Extension Cords Periodically and replace if damaged Specific Safety RulesSpecific Safety Rules Symbol Name DESIGNATION/EXPLANATION SymbolsAuthorized Service Center for repair. When servic ServiceElectrical Connection Speed and WiringElectrical Extension CordsGlossary of Terms Depth Adjustment Handle Dust Port Work Thickness Scale FeaturesProduct Specifications Switch KEY PowerLoose Parts Unpacking AssemblyMounting the Planer Installing Depth Adjustment HandleWorkbench Planing Tips OperationApplications Thickness PlaningAvoiding Snipe Power SwitchWarped Wood Planing Adjusting the Planing DepthTo Adjust the Planing Depth Depth Adjustment Handle Adjusting Knob ScaleSlide Blade Loosen AdjustmentsThickness Scale Adjustment Blade AdjustmentLubrication MaintenanceGeneral Maintenance Blade ReplacementCleaning Brush ReplacementBrush Brush CAP Problem Possible Cause Solution TroubleshootingPage Service Model NO. and Serial no