Harbor Freight Tools 32222 operating instructions Extension Cords, Unpacking, SKU REV 03/00

Page 5

EXTENSION CORDS

Your tool has a three prong plug, therefore you must use a three- prong extension cord. Only use rounded jacket extension cords listed by the Underwriters Laboratories (UL). If you are using the tool outdoors, you must use an extension cord rated for outdoor use. This is signified by the letters “WA” on the jacket.

The extension cord must have a minimum wire size depending on the amperage of the tool and the length of the extension cord. This size is signified by its AWG (American Wire Gauge) rating. The smaller the gauge, the greater the cable’s capacity. It does not matter if you are using one cord, or two or more- the total length is what is used to determine the minimum AWG rating. Every cord used must meet the AWG rating. Use the chart below to determine what AWG rating is required for your situation. Cord length is rated in feet.

AMP

 

TOTAL EXTENSION CORD(S) LENGTH IN FEET

 

RATING

25

 

50

75

100

125

150

175

200

 

 

 

 

 

 

 

 

 

 

 

 

0-10.0

18

 

18

16

16

14

14

12

12

A

10.1-13.0

16

 

16

14

14

14

12

12

12

W

13.1-15

14

 

14

12

12

12

12

12

__

G

15-18

14

 

12

12

12

12

12

__

__

 

 

 

 

 

 

 

 

 

 

 

 

Always inspect extension cords for any damage. If there are any loose, frayed, or exposed wires; damaged insulation; or defective connections, the cord must not be used. Harbor Freight Tools can supply UL listed and outdoor rated cords in multiple AWG rating if needed.

UNPACKING

When unpacking, check to make sure the following parts are included. All sizes listed below are approximate. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual.

ITEM #

DESCRIPTION

 

 

56

Replacement Belt

58

One Set Replacement Brushes

62

Blade Set Jig

63

Blade Sharpening Jig

65

Guide Fence

66

5mm T-Handle Box Wrench

 

 

Page 5 -- SKU: 32222

REV 03/00

Image 5
Contents Mission Oaks Blvd. / Camarillo, CA 4 PlanerSafety Warning & Cautions SpecificationsSave this Manual 2 -- SKU3 -- SKU 4 -- SKU Grounding InstructionsVoltage Warning 5 -- SKU REV 03/00 Extension CordsUnpacking Operations Basic ProceduresDepth Set Knob Rear Handle #36 Trigger Lock 6 -- SKU7 -- SKU Fence Use and InstallationKnob #61 Fence #65 Rabbeting MaintenanceChamfering Removing & Sharpening BladesSharpening Angle Sharpening Jig #63 Blade #19 Setting & Replacing Blades#24 Back Plate #20 Cutter Block #16Brush Replacement Pulley ReplacementPulley #54 Belt Cover #51 Screw #29 Pulley Belt #55 #56 10 -- SKU11 -- SKU Trouble Shooting Problem Probable Cause Solution12 -- SKU Parts List13 -- SKU Exploded View Drawing