8 ► SK58 User Manual
Tool to Hydraulic Circuit Hose Recommendations
The chart to the right shows recommended minimum hose diameters for various hose lengths based on gallons per minute (gpm)/ liters per minute (lpm). These recommenda- tions are intended to keep return line pressure (back pressure) to a minimum acceptable lev- el to ensure maximum tool performance.
This chart is intended to be used for hydraulic tool applications only based on Stanley Hy- draulic Tools tool operating requirements and should not be used for any other applications.
All hydraulic hose must have at least a rated minimum working pressure equal to the maxi- mum hydraulic system relief valve setting.
All hydraulic hose must meet or exceed specifications as set forth by SAE J517.
Oil Flow  | Hose Lengths  | Inside Diameter  | USE  | Min. Working Pressure  | |||||
  | 
  | 
  | 
  | 
  | 
  | (Press/Return)  | 
  | 
  | 
  | 
GPM  | LPM  | FEET | METERS | INCH | MM  | PSI | 
  | BAR | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Certified   | 
  | ||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
up to 10  | up to 3  | 3/8  | 10  | Both  | 2250  | 
  | 155  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Conductive Hose - Wire  | Braid or Fiber Braid   | NOT USE NEAR ELECTRICAL CONDUCTORS | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
up to 25  | up to 7.5  | 3/8  | 10  | Both  | 2500  | 
  | 175  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
1/2  | 13  | Both  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
up to 50  | up to 15  | 1/2  | 13  | Both  | 2500  | 
  | 175  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
5/8  | 16  | Both  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
5/8  | 16  | Pressure  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | ||||
3/4  | 19  | Return  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
up to 50  | up to 15  | 5/8  | 16  | Both  | 2500  | 
  | 175  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
5/8  | 16  | Pressure  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | ||||
3/4  | 19  | Return  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
3/4  | 19  | Pressure  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | ||||
1  | 25.4  | Return  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
up to 25  | up to 8  | 5/8  | 16  | Pressure  | 2500  | 
  | 175  | ||
  | 
  | 
  | 
  | 
  | 
  | ||||
3/4  | 19  | Return  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
3/4  | 19  | Pressure  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | 
  | ||||
1  | 25.4  | Return  | 2500  | 
  | 175  | ||||
  | 
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
PRESSURE
<<< FLOW
RETURN