Whirlpool W4GH6 installation instructions Thermal Expansion Valve, Orifice

Page 5

1.Disconnect power.

2.Remove the refrigerant from the existing system per the manufacturer’s instructions provided with the recovery system being used. Connect the R-22 gauge set is connected to both sides of the refrigerant system (as shown), and verify that the entire system is void of refrigerant in accordance with the manufacturer’s instructions provided with the recovery system being used.

3.Disconnect the liquid and vapor lines from the existing outdoor unit.

4.Remove the existing outdoor unit.

5.Set the new R-410A outdoor unit and connect the refrigerant lines. See “Connect Refrigerant Lines” steps 1 through 5. Do not evacuate the lines.

6.Remove the existing R-22 refrigerant flow control orifice or thermal expansion valve on the indoor coil, and use a field provided fitting to reconnect the lines.

Thermal Expansion Valve

A

A. Thermal expansion valve

 

Orifice

 

 

A

 

C

 

 

D

 

 

E

B

G

F

 

 

A. Distributor fitting

E. Orifice extension stub

 

B. Mounting flange

F. 0.812" brass hex nut

 

C. Piston orifice

G. Brass hex fitting

 

D. Ring seal (supplied)

 

 

7.Remove the caps from the suction and liquid pressure taps.

8.Remove the valve cores.

A

B

A. Suction pressure tap

B. Liquid pressure tap

9.Connect an R-22 cylinder with clean refrigerant to the suction pressure tap.

10.Connect the R-22 gauge set to the liquid line service valve and connect a recovery machine with an empty recovery tank to the gauge set.

11.Set the recovery machine for liquid recovery and start the recovery machine in accordance with the manufacturer’s instructions provided with the recovery system being used.

12.Open the gauge set valves to allow the recovery machine to run until a vacuum level less than 0" Hg (gauge pressure) is established in the existing system line set and indoor coil.

13.Invert the cylinder of clean R-22 and open its valve to allow liquid refrigerant to flow into the system through the vapor line valve.

14.After all of the liquid refrigerant has been recovered, switch the recovery machine to vapor recovery to allow the recovery machine to run until a vacuum level less than 0" Hg (gauge pressure) is established in the existing system line set and indoor coil in accordance with the manufacturer’s instructions provided with the recovery system being used.

NOTE: A single system flush should remove all of the mineral oil from the existing refrigerant lines and indoor coil. A second flushing may be done (using clean refrigerant) if insufficient amounts of mineral oil were removed during the first flush. A second flushing may be required to ensure that the maximum amount of oil is removed.

15.Close the valves on the inverted R-22 cylinder and gauge set.

16.Remove the recovery machine, gauges, R-22 cylinder and the field provided fitting installed in Step 6.

5

Image 5
Contents Installation Requirements Heat Pump SafetyLocation Requirements Tools and PartsSystem Requirements Installing Vertical Runs new construction shown Installing Horizontal RunsMinimum Clearances Line Set IsolationInspect Shipment Electrical RequirementsFlush Refrigerant Lines Flushing ConnectionsOrifice Thermal Expansion ValveThermal Expansion Valve Installation Install Thermal Expansion ValveTo install the thermal expansion valve Connect Refrigerant LinesRefrigerant Charge Check Charge Using Normal Operating PressuresConnect Liquid and Suction Lines Cooling-2nd Stage High Capacity Cooling-1st Stage Low CapacityHeating-1st Stage Low Capacity Heating-2nd Stage High CapacityMake Electrical Connections Single Phase Electrical ConnectionsSuction Line Sizes Liquid Line SizesWithout Auxiliary Heat Typical Wiring Connection low voltage circuitOutdoor Unit Typical Wiring Diagram Complete InstallationCooling Cycle Sequence of OperationHeating Cycle Defrost CycleAdjust Defrost System Troubleshoot the Defrost System Defrost Control Setting Defrost Test Cycle TimeSystem Diagnostic Module TroubleshootingDiagnostic LEDs Interpretation Heat Pump Fails to Operate Properly LED DescriptionLED Status Fault Description Troubleshooting Information VAC Power Wiring Thermostat Demand WiringAccessories Assistance or ServiceIncorrectly Wired Module Codes Incorrectly Wired Module TroubleshootingPage Page All rights reserved 48488A006

W4GH6 specifications

The Whirlpool W4GH6 is a cutting-edge refrigerator designed to meet the demands of modern households. With its sleek design and advanced features, it stands out as a reliable appliance that combines functionality with style.

One of the main features of the W4GH6 is its generous storage capacity. This refrigerator provides ample space for all your food storage needs, ensuring that you can store everything from fresh produce to large party platters without any hassle. The adjustable shelves allow for customizable configurations, accommodating items of various sizes.

Equipped with advanced cooling technologies, the Whirlpool W4GH6 ensures that your food stays fresher for longer. The refrigerator incorporates a multi-air flow system, which efficiently circulates cool air throughout the compartments, maintaining consistent temperatures. This technology helps prevent hotspots and ensures that all items, whether on the top or bottom shelf, receive equal cooling.

Energy efficiency is another hallmark of the W4GH6. It features an Energy Star certification, indicating that it meets strict energy efficiency guidelines set by the US Environmental Protection Agency. This means you can enjoy substantial savings on your energy bills while minimizing your environmental footprint.

The W4GH6 also offers a range of intelligent features designed for user convenience. The refrigerator comes with a temperature management system that allows users to set and monitor temperatures easily. Additionally, its frost-free operation means that you won't have to deal with the hassle of manual defrosting, making maintenance straightforward.

In terms of design, the Whirlpool W4GH6 boasts a modern aesthetic that complements any kitchen décor. The stainless steel finish not only adds a touch of elegance but also resists fingerprints and smudges, ensuring the appliance remains looking pristine.

For families with busy lifestyles, the Whirlpool W4GH6 includes a water and ice dispenser, providing easy access to chilled water and ice on demand. This feature is particularly convenient for hydration during hot days or for quickly preparing drinks for guests.

In summary, the Whirlpool W4GH6 is a versatile refrigerator that excels in both performance and style. Its spacious interior, advanced cooling technologies, and energy-efficient design make it a perfect choice for anyone looking to upgrade their kitchen appliances. With user-friendly features and a contemporary look, the W4GH6 is tailored to enhance your culinary experience while keeping your food fresher for longer.