Overview

The glossary contains terms and acronyms that are used in this manual. For definitions of point database descriptors, see Chapter 3, Point Database.

Al

Analog Input. Point that receives a signal that represents a condition which has more than two states. For example, flow rate sensors (water or air), temperature sensors (room or duct), pressure sensors (static or velocity), and humidity sensors (room, duct, or outdoor).

airflow

Rate at which a volume of air moves through a duct. Usually expressed in cubic feet per minute (cfm).

algorithm

Mathematical formula that uses varying inputs to calculate an output value.

AO

Analog Output. Physical point that generates a continuous variable signal.

BACnet

A data communication protocol for Building Automation and Control networks.

centralized control

Type of control offered by a controller that is connected by means of a Field Level Network (FLN).

cfm

Cubic Feet per Minute.

Siemens Building Technologies, Inc.

30

Image 38
Contents Siemens BACnet Heat Pump Controller Multi 125-699 Rev. BA, JulyPage Credits Service StatementTo the Reader Page Table of Contents Reversing Valve Operation Manual Conventions How to Use This ManualManual Organization Convention ExampleGetting Help Manual SymbolsNotation Symbol Meaning Application Application Description Number Product OverviewOrdering Notes Hardware Inputs Hardware OutputsReference Actuators Controller LED IndicatorsTemperature Sensors Related Equipment Siemens Building Technologies, Inc Night Mode Override Switch Control Temperature SetpointsDay/Night Mode ApplicationsCalibration Compressor Operation Heating and Cooling SwitchoverElectric Reheat Fan OperationOverriding DOs Power Failure RecoveryCentralized Alarm Monitoring Fail-safe OperationUsing Auxiliary Points Application Notes Compressor StagingReversing Valve Operation Application 2583 Control Drawing Compressor/Electric Heat Staging AppIication 2584 Control Drawing Application 2590 BACnet Heat Pump Slave Mode Using the Controller as a Point Extension DeviceApplications Point Database Description Address ApplicationRM Stpt Dial Wall SwitchRM Stpt MAX Stpt DialRmtmp Offset Ovrd TimeNGT Ovrd Rmtmp Offset + Room Temp = CTL TempCLG CMP1 OFF DAY.NGTCLG CMP1 on CLG CMP2 onREV Valve Elec HeatHTG CMP CompressorMTR1 POS MTR SetupDmpr POS FANFree CLG OFF Cycle FANFree CLG on CLG P GainSwitch Time Rval SwitchSwitch Limit HTG LoopoutError Status Switch DbandCAL Timer NGT MA CTLPoint Database Preventive Maintenance TroubleshootingBasic Service Information Safety Features Controller LEDsGlossary Equipment controller Control loopEnglish units Field panelLps Override switchSlave mode LoopoutStand-alone control UnbundleFLN IndexBST LED TX LED PIDRTS RX LED

125-699 specifications

The Siemens 125-699 is a state-of-the-art industrial control product that showcases Siemens’ commitment to innovation and quality in automation technology. This device is specifically designed for various industrial applications, providing exceptional performance and reliability.

One of the main features of the Siemens 125-699 is its robust processing capabilities. Equipped with a high-speed processor, it can handle complex control tasks efficiently, ensuring smooth operation even under demanding conditions. This makes it suitable for a wide range of applications, from manufacturing to process automation.

The device supports multiple communication protocols, which enhances its versatility. It is compatible with popular industrial communication standards such as Profinet, Profibus, and Ethernet/IP. This flexibility allows for seamless integration into existing systems and facilitates communication between various devices on the network, making it an ideal solution for modern interconnected factories.

In terms of user interface, the Siemens 125-699 offers an intuitive design with a user-friendly programming environment. The platform supports advanced programming languages, including Ladder Logic and Structured Text, enabling engineers to develop and modify control algorithms with ease. This capability not only improves efficiency but also reduces the time needed for troubleshooting and maintenance.

Another characteristic that sets the Siemens 125-699 apart is its rugged construction. Designed for harsh industrial environments, it features a durable housing that protects against dust, moisture, and extreme temperatures. This robustness ensures longevity and reliability, even in challenging conditions, which is crucial for minimizing downtime and promoting continuous operation.

Additionally, the Siemens 125-699 incorporates advanced diagnostic tools. These tools enable real-time monitoring of the system's performance, allowing operators to detect and address potential issues before they escalate. This proactive approach to maintenance is vital in enhancing productivity and ensuring the smooth operation of industrial processes.

In conclusion, the Siemens 125-699 is a comprehensive solution for industrial automation needs. Its combination of high processing power, versatile communication options, user-friendly interface, rugged design, and advanced diagnostic capabilities makes it a leading choice for companies looking to enhance their automation systems and improve operational efficiency. With Siemens' reputation for quality and innovation, the 125-699 stands as a testament to the company's dedication to advancing industrial technology.