Miller Electric UPC 838 manual Principal Safety Standards, EMF Information, About Pacemakers

Page 8

1-5. Principal Safety Standards

Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126

Safety and Health Standards, OSHA 29 CFR 1910, from Superinten- dent of Documents, U.S. Government Printing Office, Washington, D.C. 20402.

Recommended Practices for Plasma Arc Cutting, American Welding Society Standard AWS C5.2, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269.

1-6. EMF Information

Considerations About Welding Or Cutting And The Effects Of Low Frequency Electric And Magnetic Fields

Welding or cutting current, as it flows through the welding or cutting cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power-frequency electric and magnetic fields is a human- health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following proce- dures:

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202.

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Bou- levard, Rexdale, Ontario, Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec- tion, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018.

Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep cutting power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the cut as possi- ble.

About Pacemakers:

Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.

OM-202 515 Page 4

Image 8
Contents Description OM-202 515CProcesses Page Table of Contents Directives StandardsSymbol Usage Marks a special safety messagePlasma Arc Cutting Hazards Cutting can cause fire or explosionExploding Parts can injure Flying Sparks can cause injuryARC Rays can burn eyes and skin Noise can damage hearingCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Signification des symboles LE Coupage présente un risque de feu ou d’explosionUNE Décharge Électrique peut entraîner la mort Identifie un message de sécurité particulierRisque de blessure en cas LE Bruit peut endommager l’ouïeLES Fumées ET LES GAZ peuvent être dangereux LE Plasma D’ARC peut entraîner des blessuresLES Bouteilles peuvent exploser si elles sont endommagées DES Pieces Chaudes peuvent pro- voquer des brûlures gravesDES Organes Mobiles peuvent provoquer des blessures DES Particules Volantes peuvent blesser les yeuxConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques − Definitions Air Supply Precaution Use Only Oil Free Dry Compressed Air 60 sSymbols And Definitions Manufacturer’s Rating Label For CE ProductsI1max I1effDuty Cycle And Overheating − InstallationSpecifications Cutting Speed UPCMovement Do not move or operate unit Dimensions And WeightSelecting a Location Connecting Work Clamp And Gas/Air Supply Electrical Service GuideInput Voltage Input Amperes At Rated Cutting CapacityConnecting Input Power = GND/PE4070 − OperationControls Setting Gas/Air Pressure Trigger is pressed Sequence Of OperationExample Of Cutting Operation − Maintenance & Troubleshooting Routine MaintenanceEach Use Every WeekTrouble Lights Checking Shield Cup Shutdown SystemTroubleshooting Trouble RemedyOM-202 515 − Electrical Diagram Circuit Diagram For Power Source202 − Parts List Complete AssemblyDia Unitor Mkgs Description Quantity Torch, ICE-80C ICE−80C Consumables Unitor Page Page Owner’s Record