Delta-Fab Specifications (Subject to change without notice.)

 

 

Amps Input at Rated Load Output, 60 Hz, Three-Phase

 

Net

Rated Welding Output

Voltage Range DC

230 V

460 V

575 V

KVA

KW

Dimensions

Weight

 

 

 

 

 

 

 

 

 

375 A at 35 VDC,

10 – 45

69

34.5

27.5

27.5

17.5

H: 30 in (762 mm)

374 lb

100% Duty Cycle

 

4*

2*

1.6*

1.61*

0.46*

(including lift eye)

(170 kg)

 

 

 

 

 

 

 

W: 23 in (585 mm)

 

 

 

 

 

 

 

 

D: 30-1/2 in (775 mm)

 

 

 

 

 

 

 

 

(including strain relief)

 

 

 

 

 

 

 

 

 

 

*While idling.

 

 

 

 

 

 

 

 

Certified to both the Canadian and U.S. Standards for welding equipment.

24A Wire Feeder Specifications (Subject to change without notice.)

(Use with CV Power Sources.)

 

Electrode Wire

Maximum Spool

 

 

 

Input Power

Diameter Capacity

Size Capacity

Wire Speed

Dimensions

Net Weight

24 VAC, 7 A, 60 Hz

.023– 3/32 in (0.08 – 2.4 mm)

60 lb (27.2 kg)

75 – 750 IPM

H: 11 in (279 mm)

40 lb (18 kg)

 

 

 

(1.9 – 16.5 m/min)

W: 10-3/4 in (273 mm)

 

 

 

 

 

D: 23-1/2 in (597 mm)

 

 

 

 

 

 

 

Conforms to European standards.

Control Panels

1

 

3

 

 

High Temp

 

4

Shutdown

ON

2

 

 

 

Delta-Fab

OFF

 

MADE IN

 

CV Welding Power Source

MILLER ELECTRIC MFG. CO., APPLETON, WI.

 

 

 

1.Voltage Meter

2.High Temperature Shutdown Light

3.Amperage Meter

4.Power Switch with Indicator Light

Note: Weld output studs are energized by controls on the wirefeeder.

Turn off power before connecting remote device.

1

2

3

4

5

6

1.Voltage/Wire Speed Meter*

2.Voltage/Wire Speed Switch*

3.Remote Voltage Control Standard

4.Wire Speed Control

5.Jog/Purge Switch

6.Trigger Hold Switch

*Optional

Note: Power switch is on rear panel.

Performance Data

DUTY CYCLE CHART – DELTA-FAB

 

1000

 

800

 

600

AMPS

500

400

WELDING

300

 

250

 

200

 

150

 

100

10

15

20

25

30

40

50

60

70

80

90 100

% DUTY CYCLE

2

DC VOLTS

VOLT/AMP CURVE – DELTA-FAB

60

50

MAX

40

30

20

10

MIN

0

0

100

200

300

400

500

600

700

800

DC AMPS

Image 2
Contents Delta-Fab MIG Welding Power Source24A Wire Feeder Miller Electric Mfg. CoPerformance Data Delta-Fab Specifications Subject to change without noticeControl Panels Option #2 Delta-FabSystem Stationary Package PackagesOption #1 Delta-FabSystem Option #3 Delta-FabSystem MIGRunner PackageGenuine Miller Accessories Ordering Information